Benefits of Using the Hach Portable turbidity meter

Turbidity is a key parameter in water quality monitoring, as it measures the cloudiness or haziness of a fluid caused by suspended particles. High turbidity levels can indicate the presence of contaminants in water, making it essential to monitor and control turbidity levels in various applications such as drinking water treatment, wastewater treatment, and environmental monitoring.

One of the most reliable and efficient tools for measuring turbidity is the Hach Portable turbidity meter. This portable device offers numerous benefits that make it a valuable tool for water quality professionals and researchers.

alt-102

First and foremost, the Hach Portable turbidity meter is known for its accuracy and precision. It uses a nephelometric method to measure turbidity, which involves shining light through a sample and measuring the amount of light scattered by suspended particles. This method provides highly accurate and reliable results, ensuring that users can trust the data collected by the meter.

FL-9900 High Precision Type Runner Flow Controller
Measuring range Frequency 0~2K Hz
Velocity of flow 0.5~5 m/s
Instantaneous flow 0~2000 m³/h
Cumulative flow 0~9999 9999.999 m³
Applicable pipe diameter range DN15~DN100;DN125~DN300
Resolution 0.01 m³/h
Refresh rate 1s
Accuracy class Level 2.0
Repeatability ±0.5%
Sensor input Radius:0~2K Hz
Supply voltage:DC 24V(instrument internal supply)
The electronic unit automatically temperature compensates for errors +0.5%FS;
4-20mA Technical characteristics Meter/transmitter dual mode (photoelectric isolation)
Loop resistance 500Q(max),DC24V;
Transmission accuracy ±0.01mA
Control port Contact mode Passive relay control output
Load capacity Load current 5A (max)
Function selection Instantaneous flow upper/lower alarm
Mains supply Working voltage: DC24V 4V Power consumption :<; 3.OW
Cable length Factory configuration: 5m, can be agreed: (1~500) m
Environmental requirement Temperature: 0~50℃; Relative humidity: ≤85%RH
Storage environment Temperature: (-20~60) ℃; Humidity: 85%RH
Overall dimension 96×96×72mm(height × width × depth)
Opening size 92×92mm
Installation mode Disc mounted, fast fixed
Sensor Body material Body: Engineering plastic PP; Bearing :Zr02 high temperature zirconia
Flow rate range 0.5~5 m/s
Withstand pressure ≤0.6MPa
Supply voltage lDC 24V
Output pulse amplitude| Vp≥8V
Normal pipe diameter DN15~DN100;DN125~DN600
Medium characteristic Single-phase medium(0~60℃)
Installation mode Direct line insertion

In addition to its accuracy, the Hach Portable turbidity meter is also known for its ease of use. The device is lightweight and portable, making it easy to transport to different sampling locations. It features a user-friendly interface with intuitive controls, allowing users to quickly and easily take measurements in the field. This ease of use is especially valuable for field researchers and water quality professionals who need to collect data quickly and efficiently.

FL-9900 High Precision Type Runner Flow Controller
Measuring range Frequency 0~2K Hz
Velocity of flow 0.5~5 m/s
Instantaneous flow 0~2000 m³/h
Cumulative flow 0~9999 9999.999 m³
Applicable pipe diameter range DN15~DN100;DN125~DN300
Resolution 0.01 m³/h
Refresh rate 1s
Accuracy class Level 2.0
Repeatability ±0.5%
Sensor input Radius:0~2K Hz
Supply voltage:DC 24V(instrument internal supply)
The electronic unit automatically temperature compensates for errors +0.5%FS;
4-20mA Technical characteristics Meter/transmitter dual mode (photoelectric isolation)
Loop resistance 500Q(max),DC24V;
Transmission accuracy ±0.01mA
Control port Contact mode Passive relay control output
Load capacity Load current 5A (max)
Function selection Instantaneous flow upper/lower alarm
Mains supply Working voltage: DC24V 4V Power consumption :<; 3.OW
Cable length Factory configuration: 5m, can be agreed: (1~500) m
Environmental requirement Temperature: 0~50℃; Relative humidity: ≤85%RH
Storage environment Temperature: (-20~60) ℃; Humidity: 85%RH
Overall dimension 96×96×72mm(height × width × depth)
Opening size 92×92mm
Installation mode Disc mounted, fast fixed
Sensor Body material Body: Engineering plastic PP; Bearing :Zr02 high temperature zirconia
Flow rate range 0.5~5 m/s
Withstand pressure ≤0.6MPa
Supply voltage lDC 24V
Output pulse amplitude| Vp≥8V
Normal pipe diameter DN15~DN100;DN125~DN600
Medium characteristic Single-phase medium(0~60℃)
Installation mode Direct line insertion

Another key benefit of the Hach Portable turbidity meter is its durability and reliability. The device is designed to withstand harsh environmental conditions, making it suitable for use in a wide range of applications. Whether working in a laboratory setting or out in the field, users can rely on the Hach Portable turbidity meter to deliver accurate and consistent results.

Furthermore, the Hach Portable turbidity meter offers a range of features that enhance its functionality and versatility. The device is equipped with a built-in data logging function, allowing users to store and analyze measurement data over time. It also offers multiple measurement modes, including single point, continuous, and signal averaging, giving users the flexibility to choose the most appropriate mode for their specific application.

In conclusion, the Hach Portable turbidity meter is a valuable tool for water quality monitoring and research. Its accuracy, ease of use, durability, and versatility make it an essential device for professionals working in the field of water quality. By investing in a Hach Portable turbidity meter, users can ensure that they have access to reliable and accurate turbidity measurements, helping them to maintain and improve water quality in various applications.

alt-1012

Similar Posts