{"id":11098,"date":"2024-04-15T13:54:20","date_gmt":"2024-04-15T05:54:20","guid":{"rendered":"https:\/\/shchimay.com\/?p=11098"},"modified":"2024-04-15T15:53:59","modified_gmt":"2024-04-15T07:53:59","slug":"how-to-calibrate-rosemount-flow-transmitter","status":"publish","type":"post","link":"https:\/\/shchimay.com\/es\/how-to-calibrate-rosemount-flow-transmitter\/","title":{"rendered":"c\u00f3mo calibrar el transmisor de flujo rosemount"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/es\/how-to-calibrate-rosemount-flow-transmitter\/#Procedimiento_adecuado_para_calibrar_el_transmisor_de_flujo_Rosemount\" title=\"Procedimiento adecuado para calibrar el transmisor de flujo Rosemount\">Procedimiento adecuado para calibrar el transmisor de flujo Rosemount<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/es\/how-to-calibrate-rosemount-flow-transmitter\/#Errores_comunes_que_se_deben_evitar_al_calibrar_el_transmisor_de_flujo_Rosemount\" title=\"Errores comunes que se deben evitar al calibrar el transmisor de flujo Rosemount\">Errores comunes que se deben evitar al calibrar el transmisor de flujo Rosemount<\/a><\/li><\/ul><\/nav><\/div>\n<h1 id=\"proper-procedure-for-calibrating-rosemount-flow-transmitter-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Procedimiento_adecuado_para_calibrar_el_transmisor_de_flujo_Rosemount\"><\/span>Procedimiento adecuado para calibrar el transmisor de flujo Rosemount<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nLa calibraci\u00f3n de un transmisor de flujo Rosemount es un paso crucial para garantizar mediciones precisas y confiables de los caudales en procesos industriales. Una calibraci\u00f3n adecuada no s\u00f3lo mejora el rendimiento del transmisor sino que tambi\u00e9n ayuda a mantener la eficiencia general del sistema. En este art\u00edculo, analizaremos el procedimiento paso a paso para calibrar un transmisor de flujo Rosemount.<\/p>\n<p>Antes de comenzar el proceso de calibraci\u00f3n, es importante reunir todas las herramientas y equipos necesarios. Necesitar\u00e1 un kit de calibraci\u00f3n, una fuente de presi\u00f3n, un mult\u00edmetro y una computadora port\u00e1til o computadora con el software necesario para comunicarse con el transmisor. Aseg\u00farese de que el transmisor est\u00e9 correctamente instalado y conectado a la tuber\u00eda de proceso antes de continuar con la calibraci\u00f3n.<\/p>\n<p>El primer paso para calibrar un transmisor de flujo Rosemount es establecer una medici\u00f3n de referencia. Esto implica verificar las configuraciones de cero y span del transmisor para garantizar que est\u00e9 funcionando dentro del rango especificado. Para hacer esto, aplique presi\u00f3n cero al transmisor y ajuste el potenci\u00f3metro de ajuste de cero hasta que la se\u00f1al de salida indique cero. Luego, aplique una presi\u00f3n conocida al transmisor y ajuste el potenci\u00f3metro de ajuste de span hasta que la se\u00f1al de salida coincida con el valor esperado.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>N\u00fam. de modelo<\/td>\n<td colspan=\"2\">Controlador en l\u00ednea de conductividad\/concentraci\u00f3n inductiva CIT-8800<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">Rango de medici\u00f3n<\/td>\n<td>Conductividad<\/td>\n<td>0,00\u03bcS\/cm ~ 2000mS\/cm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Concentraci\u00f3n<\/td>\n<td>1.NaOH\uff0c\uff080-15\uff09 por ciento o\uff0825-50\uff09 por ciento \uff1b<\/td>\n<\/tr>\n<tr>\n<td>2.HNO3\uff08tenga en cuenta la resistencia a la corrosi\u00f3n del sensor\uff09\uff080-25\uff09 por ciento o\uff0836-82\uff09 por ciento \uff1b<\/td>\n<\/tr>\n<tr>\n<td>3.Curvas de concentraci\u00f3n definidas por el usuario.<\/td>\n<\/tr>\n<tr>\n<td>TDS<\/td>\n<td>0,00 ppm~1000 ppt<\/td>\n<\/tr>\n<tr>\n<td>Temp.<\/td>\n<td>\uff080.0 ~ 120.0\uff09\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Resoluci\u00f3n<\/td>\n<td>Conductividad<\/td>\n<td>0,01\u03bcS\/cm<\/td>\n<\/tr>\n<tr>\n<td>Concentraci\u00f3n<\/td>\n<td>0.01%<\/td>\n<\/tr>\n<tr>\n<td>TDS<\/td>\n<td>0,01 ppm<\/td>\n<\/tr>\n<tr>\n<td>Temp.<\/td>\n<td>0.1\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Precisi\u00f3n<\/td>\n<td rowspan=\"3\">Conductividad<\/td>\n<td>0\u03bcS\/cm ~1000\u03bcS\/cm \u00b110\u03bcS\/cm<\/td>\n<\/tr>\n<tr>\n<td>1 mS\/cm~500 mS\/cm \u00b11,0 por ciento <\/td>\n<\/tr>\n<tr>\n<td>500mS\/cm~2000 mS\/cm \u00b11,0 por ciento <\/td>\n<\/tr>\n<tr>\n<td>TDS<\/td>\n<td>nivel 1,5<\/td>\n<\/tr>\n<tr>\n<td>Temp.<\/td>\n<td>\u00b10.5\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Temp. compensaci\u00f3n<\/td>\n<td>elemento<\/td>\n<td>Pt1000<\/td>\n<\/tr>\n<tr>\n<td>rango<\/td>\n<td>\uff080.0~120.0\uff09\u2103 compensaci\u00f3n lineal<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\uff084~20\uff09mA Salida de corriente<\/td>\n<td>canales<\/td>\n<td>Canales dobles<\/td>\n<\/tr>\n<tr>\n<td>caracter\u00edsticas<\/td>\n<td>Aislado, ajustable, reversible, salida 4-20MA, modo instrumentos\/transmisor.<\/td>\n<\/tr>\n<tr>\n<td>Resistencia de bucle<\/td>\n<td>400\u03a9\uff08Max\uff09\uff0cCC 24V<\/td>\n<\/tr>\n<tr>\n<td>Resoluci\u00f3n<\/td>\n<td>\u00b10,1 mA<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Contacto de control<\/td>\n<td>Canales<\/td>\n<td>Canales triples<\/td>\n<\/tr>\n<tr>\n<td>Contacto<\/td>\n<td>Salida de rel\u00e9 fotoel\u00e9ctrico<\/td>\n<\/tr>\n<tr>\n<td>Programable<\/td>\n<td>Programable \uff08 temperatura \u3001conductividad\/concentraci\u00f3n\/TDS\u3001sincronizaci\u00f3n\uff09salida<\/td>\n<\/tr>\n<tr>\n<td>Caracter\u00edsticas<\/td>\n<td>Se podr\u00eda establecer temperatura\u3001conductividad\/concentraci\u00f3n\/TDS\u3001 temporizaci\u00f3n NO\/NC\/selecci\u00f3n PID<\/td>\n<\/tr>\n<tr>\n<td>Carga de resistencia<\/td>\n<td>50mA\uff08Max\uff09\uff0cCA\/CC 30V\uff08Max\uff09<\/td>\n<\/tr>\n<tr>\n<td>Comunicaci\u00f3n de datos<\/td>\n<td colspan=\"2\">RS485, protocolo MODBUS<\/td>\n<\/tr>\n<tr>\n<td>Fuente de alimentaci\u00f3n<\/td>\n<td colspan=\"2\">CC 24 V\u00b14 V<\/td>\n<\/tr>\n<tr>\n<td>Consumo<\/td>\n<td colspan=\"2\">5.5W<\/td>\n<\/tr>\n<tr>\n<td>Entorno de trabajo<\/td>\n<td colspan=\"2\">Temperatura\uff1a\uff080~50\uff09\u2103 Humedad relativa\uff1a\u226485 por ciento RH (sin condensaci\u00f3n)<\/td>\n<\/tr>\n<tr>\n<td>Almacenamiento<\/td>\n<td colspan=\"2\">Temperatura\uff1a(-20~60)\u2103 Humedad relativa\uff1a\u226485 por ciento HR (sin condensaci\u00f3n)<\/td>\n<\/tr>\n<tr>\n<td>Nivel de protecci\u00f3n<\/td>\n<td colspan=\"2\">IP65\uff08con cubierta trasera\uff09<\/td>\n<\/tr>\n<tr>\n<td>Dimensi\u00f3n del contorno<\/td>\n<td colspan=\"2\">96mm\u00d796 mm\u00d794mm (H\u00d7W\u00d7D)<\/td>\n<\/tr>\n<tr>\n<td>Dimensi\u00f3n del agujero<\/td>\n<td colspan=\"2\">91mm\u00d791mm(H\u00d7W)<\/td>\n<\/tr>\n<tr>\n<td>Instalaci\u00f3n<\/td>\n<td colspan=\"2\">Montado en panel, instalaci\u00f3n r\u00e1pida<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Una vez establecida la medici\u00f3n de referencia, el siguiente paso es realizar una verificaci\u00f3n de calibraci\u00f3n. Esto implica comparar la se\u00f1al de salida del transmisor con un est\u00e1ndar de referencia conocido para verificar su precisi\u00f3n. Conecte el transmisor al kit de calibraci\u00f3n y aplique una serie de valores de presi\u00f3n al transmisor. Registre la se\u00f1al de salida en cada punto de presi\u00f3n y comp\u00e1rela con los valores esperados. Si hay alguna discrepancia, ajuste las configuraciones de cero y span en consecuencia.<\/p>\n<p>Despu\u00e9s de completar la verificaci\u00f3n de calibraci\u00f3n, es importante realizar una prueba de linealidad para garantizar que el transmisor proporcione mediciones precisas en todo el rango. Aplique una serie de valores de presi\u00f3n al transmisor y registre la se\u00f1al de salida en cada punto. Traza los datos en un gr\u00e1fico y verifica si hay desviaciones de una l\u00ednea recta. Si los puntos de datos se desv\u00edan significativamente de la l\u00ednea esperada, es posible que sea necesario realizar ajustes para mejorar la linealidad del transmisor.<\/p>\n<p>Una vez completada la prueba de linealidad, el paso final es documentar los resultados de la calibraci\u00f3n. Registre la medici\u00f3n de referencia, los resultados de la verificaci\u00f3n de calibraci\u00f3n y los datos de la prueba de linealidad en un informe de calibraci\u00f3n. Incluya detalles como la fecha de calibraci\u00f3n, el nombre del t\u00e9cnico y cualquier ajuste realizado en la configuraci\u00f3n del transmisor. Esta documentaci\u00f3n es importante para mantener un registro del historial de calibraci\u00f3n y garantizar el cumplimiento de los requisitos reglamentarios.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/shchimay.com\/wp-content\/uploads\/2024\/04\/pexels-ivan-samkov-57990431-1024x683.jpg\" alt=\"alt-2410\" class=\"wp-image-2410\" id=\"i2410\" \/><\/p>\n<p>En conclusi\u00f3n, calibrar un transmisor de flujo Rosemount es una tarea cr\u00edtica que debe realizarse regularmente para garantizar mediciones precisas y confiables. Si sigue el procedimiento adecuado descrito en este art\u00edculo, podr\u00e1 mantener el rendimiento de su transmisor y mejorar la eficiencia general de sus procesos industriales. Recuerde reunir todas las herramientas y equipos necesarios, establecer una medici\u00f3n de referencia, realizar una verificaci\u00f3n de calibraci\u00f3n, realizar una prueba de linealidad y documentar los resultados de la calibraci\u00f3n. Con una calibraci\u00f3n adecuada, puede confiar en que su transmisor de flujo Rosemount proporcionar\u00e1 mediciones de caudal precisas y consistentes.<\/p>\n<h1 id=\"common-mistakes-to-avoid-when-calibrating-rosemount-flow-transmitter-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Errores_comunes_que_se_deben_evitar_al_calibrar_el_transmisor_de_flujo_Rosemount\"><\/span>Errores comunes que se deben evitar al calibrar el transmisor de flujo Rosemount<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nLa calibraci\u00f3n de un transmisor de flujo Rosemount es un paso crucial para garantizar mediciones de flujo precisas y confiables en procesos industriales. Sin embargo, existen errores comunes que pueden ocurrir durante el proceso de calibraci\u00f3n y que pueden generar lecturas inexactas y posibles problemas en el futuro. En este art\u00edculo, analizaremos algunos de estos errores comunes y brindaremos consejos sobre c\u00f3mo evitarlos.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"ro uv tds controller water purifier\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/1YB3-6QwTvI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>Un error com\u00fan al calibrar un transmisor de flujo Rosemount es no seguir las pautas del fabricante. Es importante leer y comprender detenidamente los procedimientos de calibraci\u00f3n descritos en el manual del usuario proporcionado por Rosemount. El incumplimiento de estas pautas puede provocar una calibraci\u00f3n inadecuada y mediciones de flujo inexactas. Aseg\u00farese de familiarizarse con los requisitos espec\u00edficos de su modelo particular de transmisor de flujo Rosemount antes de comenzar el proceso de calibraci\u00f3n.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\">Transmisor de flujo FCT-8350<\/td>\n<\/tr>\n<tr>\n<td>Rango de medici\u00f3n<\/td>\n<td>Flujo instant\u00e1neo:(0~2000)m3\/h;Flujo acumulado:(0~99999999)m3<\/td>\n<\/tr>\n<tr>\n<td>Flujo<\/td>\n<td>(0~5)m\/s<\/td>\n<\/tr>\n<tr>\n<td>Di\u00e1metro de tuber\u00eda aplicable<\/td>\n<td>DN 25~DN 1000 para selecci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Resoluci\u00f3n<\/td>\n<td>0,001m3\/h<\/td>\n<\/tr>\n<tr>\n<td>Intervalo de renovaci\u00f3n<\/td>\n<td>1S<\/td>\n<\/tr>\n<tr>\n<td>Precisi\u00f3n<\/td>\n<td>nivel 2.0<\/td>\n<\/tr>\n<tr>\n<td>Repetibilidad<\/td>\n<td>\u00b10,5 por ciento<\/td>\n<\/tr>\n<tr>\n<td>Entrada de sonda<\/td>\n<td>Rango: 0,5 Hz ~ 2 KHz; Fuente de alimentaci\u00f3n: CC 12 V (fuente de instrumento)<\/td>\n<\/tr>\n<tr>\n<td>Salida anal\u00f3gica<\/td>\n<td>(4~20)mA, Instrumento\/transmisor para selecci\u00f3n;<\/td>\n<\/tr>\n<tr>\n<td>Salida de control<\/td>\n<td>Rel\u00e9 fotoelectr\u00f3nico semiconductor, corriente de carga 50 mA (m\u00e1x.), CA\/CC 30 V<\/td>\n<\/tr>\n<tr>\n<td>Modo de control<\/td>\n<td>Alarma de l\u00edmite alto\/bajo de flujo instant\u00e1neo, conversi\u00f3n de frecuencia variable de flujo<\/td>\n<\/tr>\n<tr>\n<td>Poder de trabajo<\/td>\n<td>CC24V<\/td>\n<\/tr>\n<tr>\n<td>Consumo de energ\u00eda:<\/td>\n<td> y lt;3.0W<\/td>\n<\/tr>\n<tr>\n<td>Longitud del cable<\/td>\n<td>5 m como est\u00e1ndar; o(1~500)m para selecci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Entorno de trabajo<\/td>\n<td>Temp.:(0~50)\u2103;humedad relativa\u226485 por ciento RH (sin condensaci\u00f3n)<\/td>\n<\/tr>\n<tr>\n<td>Entorno de almacenamiento<\/td>\n<td>Temp.:(-20~60)\u2103; Humedad relativa:\u226485 por ciento RH (sin condensaci\u00f3n)<\/td>\n<\/tr>\n<tr>\n<td>Nivel de protecci\u00f3n<\/td>\n<td>IP65 (con cubierta trasera)<\/td>\n<\/tr>\n<tr>\n<td>Dimensi\u00f3n<\/td>\n<td>96 mm\u00d796 mm\u00d794mm (H\u00d7W\u00d7D)<\/td>\n<\/tr>\n<tr>\n<td>Tama\u00f1o del agujero<\/td>\n<td>91mm\u00d791mm(H\u00d7W)<\/td>\n<\/tr>\n<tr>\n<td>Instalaci\u00f3n<\/td>\n<td>Montado en panel, instalaci\u00f3n r\u00e1pida<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nOtro error com\u00fan es no preparar adecuadamente el equipo antes de la calibraci\u00f3n. Antes de calibrar el transmisor de flujo, es importante asegurarse de que el equipo est\u00e9 limpio y libre de residuos u obstrucciones que puedan afectar el proceso de calibraci\u00f3n. Adem\u00e1s, aseg\u00farese de que todas las herramientas y equipos necesarios est\u00e9n disponibles y en buenas condiciones de funcionamiento. Tomarse el tiempo para preparar adecuadamente el equipo antes de la calibraci\u00f3n puede ayudar a garantizar resultados precisos y confiables.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"High Accuracy 4-20mA Absolute Pressure Transmitter For Liquid Gas And Steam\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/EL0pJGBee4I?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>Uno de los errores m\u00e1s comunes cometidos durante la calibraci\u00f3n es no dejar suficiente tiempo para el proceso. Calibrar un transmisor de flujo puede ser una tarea que requiere mucho tiempo y apresurarse en el proceso puede provocar errores e imprecisiones. Es importante reservar una cantidad de tiempo adecuada para la calibraci\u00f3n y seguir cada paso cuidadosamente para garantizar resultados precisos. Tomarse el tiempo para calibrar correctamente el transmisor de flujo ayudar\u00e1 a prevenir problemas y garantizar mediciones de flujo confiables.<\/p>\n<p>Otro error com\u00fan que se debe evitar al calibrar un transmisor de flujo Rosemount es no realizar calibraciones peri\u00f3dicas. Con el tiempo, el rendimiento del transmisor de flujo puede variar, lo que genera lecturas inexactas. Es importante establecer un programa de calibraci\u00f3n regular y cumplirlo para garantizar que el transmisor de flujo funcione correctamente. Las calibraciones peri\u00f3dicas pueden ayudar a identificar cualquier problema desde el principio y prevenir posibles problemas en el futuro.<\/p>\n<p>Un \u00faltimo error com\u00fan que se debe evitar al calibrar un transmisor de flujo Rosemount es no documentar el proceso de calibraci\u00f3n. Mantener registros detallados de cada calibraci\u00f3n, incluida la fecha, la hora y los resultados, puede ayudar a realizar un seguimiento del rendimiento del transmisor de flujo a lo largo del tiempo. Esta documentaci\u00f3n puede ser valiosa para solucionar cualquier problema que pueda surgir y para garantizar el cumplimiento de los requisitos reglamentarios.<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CLA-7000-series-Total-chlorine-DPD-Online-1.png\" alt=\"alt-2422\" class=\"wp-image-2422\" id=\"i2422\" \/><\/p>\n<p>En conclusi\u00f3n, calibrar un transmisor de flujo Rosemount es una tarea cr\u00edtica que debe realizarse con cuidado y precisi\u00f3n para garantizar mediciones de flujo confiables. Al evitar errores comunes, como no seguir las pautas del fabricante, no preparar adecuadamente el equipo, apresurar el proceso, descuidar las calibraciones peri\u00f3dicas y no documentar el proceso, puede ayudar a garantizar resultados precisos y confiables. Tomarse el tiempo para calibrar correctamente su transmisor de flujo Rosemount le ayudar\u00e1 a prevenir problemas y garantizar mediciones de flujo precisas en sus procesos industriales.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Procedimiento adecuado para calibrar el transmisor de flujo Rosemount La calibraci\u00f3n de un transmisor de flujo Rosemount es un paso crucial para garantizar mediciones precisas y confiables de los caudales en procesos industriales. Una calibraci\u00f3n adecuada no s\u00f3lo mejora el rendimiento del transmisor sino que tambi\u00e9n ayuda a mantener la eficiencia general del sistema. En&#8230;<\/p>\n","protected":false},"author":1,"featured_media":2029,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[200],"tags":[],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"es","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":false,"content":false,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":false,"content":false,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts\/11098"}],"collection":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/comments?post=11098"}],"version-history":[{"count":11,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts\/11098\/revisions"}],"predecessor-version":[{"id":11221,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts\/11098\/revisions\/11221"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/media\/2029"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/media?parent=11098"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/categories?post=11098"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/tags?post=11098"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}