{"id":31147,"date":"2026-07-24T07:34:09","date_gmt":"2026-07-23T23:34:09","guid":{"rendered":"https:\/\/shchimay.com\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/"},"modified":"2026-07-24T07:34:09","modified_gmt":"2026-07-23T23:34:09","slug":"softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide","status":"publish","type":"post","link":"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/","title":{"rendered":"Softener Valve Selection for Commercial Make-Up Water Trains: A Shanghai ChiMay Procurement Guide"},"content":{"rendered":"<hr \/>\n<p>title: &ldquo;<a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> Selection for Commercial Make-Up Water Trains: A Shanghai ChiMay Procurement Guide&rdquo;<br \/>\nperspective: Purchasing<br \/>\ntheme: HVAC &amp; Data Center Cooling Water<br \/>\ndate: 2026-07-04<\/p>\n<hr \/>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#softener_valve_Selection_for_Commercial_Make-Up_Water_Trains_A_Shanghai_ChiMay_Procurement_Guide\" title=\"softener valve Selection for Commercial Make-Up Water Trains: A Shanghai ChiMay Procurement Guide\">softener valve Selection for Commercial Make-Up Water Trains: A Shanghai ChiMay Procurement Guide<\/a><ul class='ez-toc-list-level-2'><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#Key_Takeaways\" title=\"Key Takeaways\">Key Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#Why_softener_valve_Choice_Punches_Above_Its_Weight\" title=\"Why softener valve Choice Punches Above Its Weight\">Why softener valve Choice Punches Above Its Weight<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#Five_Procurement_Gates_for_Commercial_Softener_Valves\" title=\"Five Procurement Gates for Commercial Softener Valves\">Five Procurement Gates for Commercial Softener Valves<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#1_Service_Flow_and_Peak_Demand\" title=\"1. Service Flow and Peak Demand\">1. Service Flow and Peak Demand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#2_Regeneration_Logic\" title=\"2. Regeneration Logic\">2. Regeneration Logic<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#3_Seal_Chemistry_and_Wetted_Materials\" title=\"3. Seal Chemistry and Wetted Materials\">3. Seal Chemistry and Wetted Materials<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#4_Communications_and_BMS_Integration\" title=\"4. Communications and BMS Integration\">4. Communications and BMS Integration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#5_Spare-Parts_Availability\" title=\"5. Spare-Parts Availability\">5. Spare-Parts Availability<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#Shanghai_ChiMay_softener_valve_Options\" title=\"Shanghai ChiMay softener valve Options\">Shanghai ChiMay softener valve Options<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#Sizing_Snapshot_A_Typical_Commercial_Deployment\" title=\"Sizing Snapshot: A Typical Commercial Deployment\">Sizing Snapshot: A Typical Commercial Deployment<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#Comparative_Snapshot_Residential-Grade_vs_Commercial-Grade_softener_valve\" title=\"Comparative Snapshot: Residential-Grade vs. Commercial-Grade softener valve\">Comparative Snapshot: Residential-Grade vs. Commercial-Grade softener valve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#The_Cost_Case\" title=\"The Cost Case\">The Cost Case<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#A_Procurement_Checklist_for_the_Next_softener_valve_RFQ\" title=\"A Procurement Checklist for the Next softener valve RFQ\">A Procurement Checklist for the Next softener valve RFQ<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/shchimay.com\/es\/softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\/#Outlook\" title=\"Outlook\">Outlook<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 id=\"softener-valve-selection-for-commercial-make-up-water-trains-a-shanghai-chimay-procurement-guide\"><span class=\"ez-toc-section\" id=\"softener_valve_Selection_for_Commercial_Make-Up_Water_Trains_A_Shanghai_ChiMay_Procurement_Guide\"><\/span><a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> Selection for Commercial Make-Up Water Trains: A Shanghai ChiMay Procurement Guide<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<h2 id=\"key-takeaways\"><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>Hard make-up water is the largest single driver of scale, downtime, and premature heat-exchanger failure in commercial HVAC systems, with total hardness above <strong>180 mg\/L as CaCO3<\/strong> commonly regarded as the trigger for softening.<\/li>\n<li><a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> selection hinges on service flow, regeneration frequency, cycle logic, and integration with the downstream conductivity and pH monitoring loop.<\/li>\n<li>Two Shanghai ChiMay <a href=\"\/tag\/control-valve\/\" target=\"_blank\"><strong>control valve<\/strong><\/a> families are directly applicable to HVAC make-up trains: <strong><a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a><\/strong> for standard cation exchange and <strong>Softening and filtering valve<\/strong> for combined softening plus particulate filtration.<\/li>\n<li>Procurement should evaluate valves on a five-point rubric: capacity match, cycle programmability, seal chemistry, communications, and long-term spare-parts availability.<\/li>\n<\/ul>\n<h2 id=\"why-softener-valve-choice-punches-above-its-weight\"><span class=\"ez-toc-section\" id=\"Why_softener_valve_Choice_Punches_Above_Its_Weight\"><\/span>Why <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> Choice Punches Above Its Weight<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An HVAC engineer once summarized the truth of commercial water treatment as: &ldquo;The chiller costs a million dollars, the <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> costs a few thousand \u2014 and the <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> is what will actually kill the chiller.&rdquo; That is not hyperbole. A single failed regeneration cycle can push hardness spikes of 300\u2013500 mg\/L into the make-up train for hours, seeding calcium carbonate scale on tubes that were pristine at commissioning.<\/p>\n<p>The good news is that softener valves are cheap relative to the systems they protect. The bad news is that procurement teams frequently under-specify them, defaulting to whatever residential-grade product the mechanical contractor happens to stock. In a commercial or data-center context, that shortcut is expensive.<\/p>\n<h2 id=\"five-procurement-gates-for-commercial-softener-valves\"><span class=\"ez-toc-section\" id=\"Five_Procurement_Gates_for_Commercial_Softener_Valves\"><\/span>Five Procurement Gates for Commercial Softener Valves<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"1-service-flow-and-peak-demand\"><span class=\"ez-toc-section\" id=\"1_Service_Flow_and_Peak_Demand\"><\/span>1. Service Flow and Peak Demand<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Commercial HVAC make-up demand is bursty. A cooling tower on a hot afternoon can spike make-up flow to <strong>2\u20133\u00d7 nominal design<\/strong>. Valves must be sized to the peak, not the average. Common failure modes \u2014 high pressure drop, resin channeling, salt-slug carryover \u2014 all stem from under-sized valves running at 120% of their rated Cv.<\/p>\n<h3 id=\"2-regeneration-logic\"><span class=\"ez-toc-section\" id=\"2_Regeneration_Logic\"><\/span>2. Regeneration Logic<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Old-generation valves regenerate on a timer. Modern commercial applications should regenerate on <strong>metered volume<\/strong> or, better, on <strong>water-quality feedback<\/strong> from a downstream conductivity sensor. Metered regeneration typically cuts salt and water consumption by 20\u201340% compared with timer-based cycles.<\/p>\n<h3 id=\"3-seal-chemistry-and-wetted-materials\"><span class=\"ez-toc-section\" id=\"3_Seal_Chemistry_and_Wetted_Materials\"><\/span>3. Seal Chemistry and Wetted Materials<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Elastomer seals are the number-one wear item. FKM (Viton) and EPDM are standard; FFKM (Kalrez) is worth specifying for buildings using chlorinated make-up water or aggressive biocides. Body materials should be Noryl, PPO, or brass depending on temperature and pressure. Skimping here is the fastest way to a mid-life valve rebuild.<\/p>\n<h3 id=\"4-communications-and-bms-integration\"><span class=\"ez-toc-section\" id=\"4_Communications_and_BMS_Integration\"><\/span>4. Communications and BMS Integration<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Modern facilities want their softener status inside the BMS. Look for valves with dry contact outputs at minimum, and Modbus RTU communication where cycle status, regeneration events, and salt-level alarms need to be visible to operations. This turns a &ldquo;dumb&rdquo; valve into a maintainable asset.<\/p>\n<h3 id=\"5-spare-parts-availability\"><span class=\"ez-toc-section\" id=\"5_Spare-Parts_Availability\"><\/span>5. Spare-Parts Availability<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Softener valves live 15\u201325 years in commercial service. A vendor that discontinues seal kits or piston assemblies after 5 years is a hidden liability. Buyers should require written commitment to spare-parts availability for at least a decade.<\/p>\n<h2 id=\"shanghai-chimay-softener-valve-options\"><span class=\"ez-toc-section\" id=\"Shanghai_ChiMay_softener_valve_Options\"><\/span>Shanghai ChiMay <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> Options<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Shanghai ChiMay offers two control-valve families relevant to HVAC make-up trains:<\/p>\n<table>\n<thead>\n<tr>\n<th>Configuration<\/th>\n<th>Typical Use<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong><a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a><\/strong><\/td>\n<td>Standard cation exchange for commercial HVAC and cooling tower make-up<\/td>\n<td>Metered or timer regeneration, Modbus RTU option, sized DN25 to DN80<\/td>\n<\/tr>\n<tr>\n<td><strong>Softening and filtering valve<\/strong><\/td>\n<td>Combined softening plus particulate\/sediment filtration in a single valve body<\/td>\n<td>Reduces footprint in mechanical rooms with limited real estate; particularly relevant where make-up water carries suspended solids<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Both are designed to pair naturally with Shanghai ChiMay&rsquo;s in-line <a href=\"\/tag\/Conductivity-Meter\" target=\"_blank\"><strong><a href=\"\/tag\/conductivity-meter\/\" target=\"_blank\"><strong>conductivity meter<\/strong><\/a><\/strong><\/a> and multi-parameter sensor family, so the softener output can be monitored continuously and regeneration triggered on a real conductivity setpoint rather than an educated guess.<\/p>\n<h2 id=\"sizing-snapshot-a-typical-commercial-deployment\"><span class=\"ez-toc-section\" id=\"Sizing_Snapshot_A_Typical_Commercial_Deployment\"><\/span>Sizing Snapshot: A Typical Commercial Deployment<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider a 1,500-ton HVAC plant with a design cooling-tower evaporation rate of about 27 gpm and an assumed 5 cycles of concentration. Make-up demand at peak load is roughly:<\/p>\n<ul>\n<li>Continuous make-up: 27 gpm (evaporation) + 6.8 gpm (blowdown) \u2248 <strong>34 gpm<\/strong><\/li>\n<li>Peak with drift and startup: ~<strong>50 gpm<\/strong><\/li>\n<li>Resin capacity target: 24\u201348 hours between regenerations at 300 mg\/L hardness make-up<\/li>\n<\/ul>\n<p>A DN50 <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> with metered regeneration and a 5-cubic-foot resin tank is a reasonable starting point. If the make-up water also carries seasonal turbidity \u2014 a common issue for surface-fed municipal supplies \u2014 the <strong>Softening and filtering valve<\/strong> collapses two vessels into one and simplifies the mechanical room layout.<\/p>\n<h2 id=\"comparative-snapshot-residential-grade-vs-commercial-grade-softener-valve\"><span class=\"ez-toc-section\" id=\"Comparative_Snapshot_Residential-Grade_vs_Commercial-Grade_softener_valve\"><\/span>Comparative Snapshot: Residential-Grade vs. Commercial-Grade <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table>\n<thead>\n<tr>\n<th>Attribute<\/th>\n<th>Residential-Grade Valve<\/th>\n<th>Commercial-Grade Shanghai ChiMay Valve<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Nominal size<\/td>\n<td>DN20\u2013DN25<\/td>\n<td>DN25\u2013DN80<\/td>\n<\/tr>\n<tr>\n<td>Regeneration logic<\/td>\n<td>Timer<\/td>\n<td>Metered \/ conductivity-triggered<\/td>\n<\/tr>\n<tr>\n<td>Communications<\/td>\n<td>None<\/td>\n<td>Modbus RTU \/ dry contacts<\/td>\n<\/tr>\n<tr>\n<td>Seal chemistry<\/td>\n<td>Standard EPDM<\/td>\n<td>FKM standard, FFKM available<\/td>\n<\/tr>\n<tr>\n<td>Spare-parts availability<\/td>\n<td>3\u20135 years<\/td>\n<td>10+ years written commitment<\/td>\n<\/tr>\n<tr>\n<td>Rated service life<\/td>\n<td>7\u201310 years<\/td>\n<td>15\u201325 years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"the-cost-case\"><span class=\"ez-toc-section\" id=\"The_Cost_Case\"><\/span>The Cost Case<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A large commercial property manager audited its make-up water infrastructure in 2024 and found that buildings running residential-grade softener valves experienced roughly <strong>2.3\u00d7 more chiller-tube fouling incidents<\/strong> than buildings running commercial-grade valves with metered regeneration. Total avoided maintenance and premature replacement across the portfolio was estimated at <strong>USD 1.4 million per year<\/strong>, against an incremental valve capex of about USD 220,000. Payback landed inside 3 months.<\/p>\n<h2 id=\"a-procurement-checklist-for-the-next-softener-valve-rfq\"><span class=\"ez-toc-section\" id=\"A_Procurement_Checklist_for_the_Next_softener_valve_RFQ\"><\/span>A Procurement Checklist for the Next <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> RFQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li>Publish the make-up water analysis (hardness, TDS, turbidity, chlorine) up front.<\/li>\n<li>Specify peak service flow \u2014 not average \u2014 as the sizing basis.<\/li>\n<li>Require metered or conductivity-triggered regeneration, not timer-only.<\/li>\n<li>Ask for FKM as the baseline seal chemistry, FFKM as an available option.<\/li>\n<li>Require Modbus RTU or dry-contact outputs for BMS integration.<\/li>\n<li>Demand written spare-parts availability for at least 10 years.<\/li>\n<li>Consider a combined Softening and filtering valve where footprint and turbidity favor consolidation.<\/li>\n<\/ol>\n<h2 id=\"outlook\"><span class=\"ez-toc-section\" id=\"Outlook\"><\/span>Outlook<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Commercial water treatment has quietly become a data-driven discipline. Softener valves are no longer stand-alone appliances; they are nodes in a monitored make-up water train that reports back to the BMS and to sustainability dashboards. Buyers who invest in commercial-grade valves \u2014 supported by continuous conductivity, pH, and residual chlorine monitoring \u2014 protect not only their chillers and heat exchangers but also their operating budget. Shanghai ChiMay&rsquo;s <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> and Softening and filtering valve options are engineered for exactly this modern, integrated procurement approach.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>title: &ldquo;<a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> Selection for Commercial Make-Up Water Trains: A Shanghai ChiMay Procurement Guide&rdquo; perspective: Purchasing theme: HVAC &amp; Data Center Cooling Water date: 2026-07-04 <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> Selection for Commercial Make-Up Water Trains: A Shanghai ChiMay Procurement Guide Key Takeaways Hard make-up water is the largest single driver of scale, downtime, and premature heat-exchanger failure&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[1],"tags":[158,141,207,147],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"es","enabled_languages":["en","es","fr","ru","ar"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts\/31147"}],"collection":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/comments?post=31147"}],"version-history":[{"count":0,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts\/31147\/revisions"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/media?parent=31147"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/categories?post=31147"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/tags?post=31147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}