{"id":31168,"date":"2026-07-25T10:14:11","date_gmt":"2026-07-25T02:14:11","guid":{"rendered":"https:\/\/shchimay.com\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/"},"modified":"2026-07-25T10:14:11","modified_gmt":"2026-07-25T02:14:11","slug":"turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay","status":"publish","type":"post","link":"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/","title":{"rendered":"Turbine Flow Measurement for Hydrogen Feedwater Skid Integration: Accuracy Practices from Shanghai ChiMay"},"content":{"rendered":"<hr \/>\n<p>title: &ldquo;Turbine Flow Measurement for Hydrogen Feedwater Skid Integration: Accuracy Practices from Shanghai ChiMay&rdquo;<br \/>\ndate: 2026-07-06<br \/>\ncategory: Green Hydrogen<br \/>\naudience: Technical<br \/>\ntags: [turbine <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a>, hydrogen skid, feedwater, flow measurement]<\/p>\n<hr \/>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Turbine_Flow_Measurement_for_Hydrogen_Feedwater_Skid_Integration_Accuracy_Practices_from_Shanghai_ChiMay\" title=\"Turbine Flow Measurement for Hydrogen Feedwater Skid Integration: Accuracy Practices from Shanghai ChiMay\">Turbine Flow Measurement for Hydrogen Feedwater Skid Integration: Accuracy Practices from Shanghai ChiMay<\/a><ul class='ez-toc-list-level-2'><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Key_Takeaways\" title=\"Key Takeaways\">Key Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Why_Flow_Measurement_Is_Central_on_a_Hydrogen_Feedwater_Skid\" title=\"Why Flow Measurement Is Central on a Hydrogen Feedwater Skid\">Why Flow Measurement Is Central on a Hydrogen Feedwater Skid<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#How_a_Turbine_flow_meter_Works\" title=\"How a Turbine flow meter Works\">How a Turbine flow meter Works<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Installation_Geometry_Straight_Runs_Matter\" title=\"Installation Geometry: Straight Runs Matter\">Installation Geometry: Straight Runs Matter<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Bearings_Materials_and_Wetted_Parts\" title=\"Bearings, Materials and Wetted Parts\">Bearings, Materials and Wetted Parts<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Calibration_What_%E2%80%9CTraceable%E2%80%9D_Really_Means\" title=\"Calibration: What &ldquo;Traceable&rdquo; Really Means\">Calibration: What &ldquo;Traceable&rdquo; Really Means<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Response_to_Real_Hydrogen_Skid_Conditions\" title=\"Response to Real Hydrogen Skid Conditions\">Response to Real Hydrogen Skid Conditions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Data_Integration_on_the_Hydrogen_Skid\" title=\"Data Integration on the Hydrogen Skid\">Data Integration on the Hydrogen Skid<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Common_Failure_Modes\" title=\"Common Failure Modes\">Common Failure Modes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Design_Practices_for_Compact_Skids\" title=\"Design Practices for Compact Skids\">Design Practices for Compact Skids<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Shanghai_ChiMay_Turbine_Flow_Meters_on_Hydrogen_Skids\" title=\"Shanghai ChiMay Turbine Flow Meters on Hydrogen Skids\">Shanghai ChiMay Turbine Flow Meters on Hydrogen Skids<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Engineering_Playbook\" title=\"Engineering Playbook\">Engineering Playbook<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/shchimay.com\/es\/turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 id=\"turbine-flow-measurement-for-hydrogen-feedwater-skid-integration-accuracy-practices-from-shanghai-chimay\"><span class=\"ez-toc-section\" id=\"Turbine_Flow_Measurement_for_Hydrogen_Feedwater_Skid_Integration_Accuracy_Practices_from_Shanghai_ChiMay\"><\/span>Turbine Flow Measurement for Hydrogen Feedwater Skid Integration: Accuracy Practices from Shanghai ChiMay<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<h2 id=\"key-takeaways\"><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>Turbine flow meters are widely selected for hydrogen feedwater skids because they combine high linearity, low pressure drop and clean digital output over a wide flow range.<\/li>\n<li>Practical accuracy of a <a href=\"\/tag\/turbine-meter\" target=\"_blank\"><strong>turbine meter<\/strong><\/a> is set by installation geometry, calibration discipline and fluid conditioning \u2014 not by the meter itself.<\/li>\n<li>Standard 10D upstream \/ 5D downstream straight-run requirements apply on hydrogen skids and are easy to violate on space-constrained modules.<\/li>\n<li>Shanghai ChiMay turbine flow meters are specified for feedwater skids with wetted materials, K-factor documentation and digital output suited to modern hydrogen plant historians.<\/li>\n<\/ul>\n<h2 id=\"why-flow-measurement-is-central-on-a-hydrogen-feedwater-skid\"><span class=\"ez-toc-section\" id=\"Why_Flow_Measurement_Is_Central_on_a_Hydrogen_Feedwater_Skid\"><\/span>Why Flow Measurement Is Central on a Hydrogen Feedwater Skid<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Every green hydrogen plant runs on water balance. Producing 1 kg of hydrogen consumes roughly 9 L of water at the stack, plus additional water for cooling, blowdown and RO reject. If any leg of the water balance is unmeasured or mis-measured, the plant cannot:<br \/>\n&#8211; Report its actual specific water consumption (litres per kg H\u2082) to management or lenders.<br \/>\n&#8211; Detect small leaks before they become large losses.<br \/>\n&#8211; Reconcile utility bills with process output.<br \/>\n&#8211; Feed the digital twin with a credible mass-balance input.<\/p>\n<p>The feedwater skid is where these flows converge, and turbine flow meters are the most common choice for the main service lines because they combine wide turndown, low pressure drop and clean digital output. Getting turbine flow measurement right on a hydrogen skid is therefore an engineering priority, not an afterthought.<\/p>\n<h2 id=\"how-a-turbine-flow-meter-works\"><span class=\"ez-toc-section\" id=\"How_a_Turbine_flow_meter_Works\"><\/span>How a Turbine <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a> Works<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A turbine <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a> uses a bladed rotor placed axially in the flow. Fluid velocity turns the rotor; a pickup coil (magnetic or reluctance-based) senses each blade passage, generating a pulse train whose frequency is proportional to volumetric flow rate.<\/p>\n<p>Two properties give turbine meters their reputation:<br \/>\n&#8211; <strong>Linearity<\/strong>: over the specified flow range, the K-factor (pulses per unit volume) is nearly constant, typically within \u00b10.5% of reading.<br \/>\n&#8211; <strong>Turndown<\/strong>: many industrial turbine meters achieve 10:1 or greater turndown while maintaining accuracy.<\/p>\n<p>But the same design has a set of installation and operating requirements that must be respected.<\/p>\n<h2 id=\"installation-geometry-straight-runs-matter\"><span class=\"ez-toc-section\" id=\"Installation_Geometry_Straight_Runs_Matter\"><\/span>Installation Geometry: Straight Runs Matter<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The most common source of <a href=\"\/tag\/turbine-meter\" target=\"_blank\"><strong>turbine meter<\/strong><\/a> error on hydrogen skids is disturbed inlet flow. A pump discharge, an elbow, a partially open valve or a T-junction all produce swirl and non-axisymmetric velocity profiles that the rotor &ldquo;sees&rdquo; as false flow.<\/p>\n<p>Standard guidance for water-service turbine meters:<br \/>\n&#8211; <strong>\u226510 pipe diameters (10D) of straight run upstream<\/strong>.<br \/>\n&#8211; <strong>\u22655 pipe diameters (5D) of straight run downstream<\/strong>.<br \/>\n&#8211; <strong>A flow straightener<\/strong> in cases where straight-run requirements cannot be met.<\/p>\n<p>On a compact skid, 10D upstream can be difficult to achieve. When space is genuinely constrained, an integral straightening element or a different meter technology should be evaluated during design \u2014 not retrofitted after commissioning.<\/p>\n<h2 id=\"bearings-materials-and-wetted-parts\"><span class=\"ez-toc-section\" id=\"Bearings_Materials_and_Wetted_Parts\"><\/span>Bearings, Materials and Wetted Parts<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Turbine meters run on bearings that operate immersed in the process fluid. For hydrogen feedwater service, the bearing choice matters:<br \/>\n&#8211; <strong>Ceramic or tungsten carbide bearings<\/strong> offer long life in clean water.<br \/>\n&#8211; <strong>Sleeve bearings<\/strong> are simpler but sensitive to particulate wear.<br \/>\n&#8211; <strong>Ball bearings<\/strong> achieve high accuracy but require clean fluid.<\/p>\n<p>Wetted materials should match the feedwater chemistry. For post-RO permeate and polished water, stainless steel 316L is common. For KOH make-up lines on alkaline plants, more corrosion-tolerant materials should be specified. For seawater intake ahead of SWRO, wetted parts must resist chloride pitting.<\/p>\n<p>Filtration ahead of the meter is a cheap upgrade with a large accuracy payoff. Even a 50-\u00b5m strainer removes debris that would otherwise damage bearings and shift the K-factor.<\/p>\n<h2 id=\"calibration-what-traceable-really-means\"><span class=\"ez-toc-section\" id=\"Calibration_What_%E2%80%9CTraceable%E2%80%9D_Really_Means\"><\/span>Calibration: What &ldquo;Traceable&rdquo; Really Means<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The K-factor supplied with a <a href=\"\/tag\/turbine-meter\" target=\"_blank\"><strong>turbine meter<\/strong><\/a> is derived from a calibration run at a testing laboratory. For hydrogen skid service, engineering should confirm:<br \/>\n&#8211; <strong>Traceability<\/strong> to a national metrology institute.<br \/>\n&#8211; <strong>Calibration in a fluid representative of the actual service<\/strong> \u2014 clean water is standard for feedwater applications.<br \/>\n&#8211; <strong>Documented calibration points<\/strong> across the operating range, not just at nominal flow.<br \/>\n&#8211; <strong>Certificate retention<\/strong> for the life of the meter, since lender due-diligence occasionally requests them years later.<\/p>\n<p>Recalibration cadence depends on service duty. A meter on a clean UPW loop with light duty may hold calibration for years; a meter on a raw seawater intake often requires annual recalibration.<\/p>\n<h2 id=\"response-to-real-hydrogen-skid-conditions\"><span class=\"ez-toc-section\" id=\"Response_to_Real_Hydrogen_Skid_Conditions\"><\/span>Response to Real Hydrogen Skid Conditions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Hydrogen feedwater skids present three conditions that shape <a href=\"\/tag\/turbine-meter\" target=\"_blank\"><strong>turbine meter<\/strong><\/a> design:<\/p>\n<p><strong>1. Load-following operation.<\/strong> As electrolyzer output ramps with renewable input, feedwater demand varies. A meter with excellent linearity across a 10:1 turndown is essential.<\/p>\n<p><strong>2. Frequent stop\u2013start cycles.<\/strong> Repeated flow interruptions accelerate bearing wear if bearings are inadequate for cyclic duty; the specification should call this out.<\/p>\n<p><strong>3. High-purity fluid.<\/strong> Wetted materials should not release ions into the feedwater. Bearing choice and shaft materials are part of the water-quality equation, not just the flow equation.<\/p>\n<h2 id=\"data-integration-on-the-hydrogen-skid\"><span class=\"ez-toc-section\" id=\"Data_Integration_on_the_Hydrogen_Skid\"><\/span>Data Integration on the Hydrogen Skid<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A modern hydrogen skid feeds flow, conductivity, pH, DO and pressure signals into a common historian. For turbine meters, that means the transmitter should support:<br \/>\n&#8211; <strong>Pulse-per-litre output<\/strong> for high-resolution local totalising.<br \/>\n&#8211; <strong>Analog 4\u201320 mA output<\/strong> for legacy DCS integration.<br \/>\n&#8211; <strong>Digital protocol<\/strong> (Modbus, HART, or increasingly OPC UA) for direct integration into the plant historian and digital twin.<br \/>\n&#8211; <strong>Diagnostic tags<\/strong> carrying bearing-condition and signal-strength indicators.<\/p>\n<p>When flow is streamed alongside conductivity and DO from the same skid, the digital twin can reconcile mass and energy balances with confidence.<\/p>\n<h2 id=\"common-failure-modes\"><span class=\"ez-toc-section\" id=\"Common_Failure_Modes\"><\/span>Common Failure Modes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Turbine flow measurement fails in recognisable patterns:<\/p>\n<table>\n<thead>\n<tr>\n<th>Symptom<\/th>\n<th>Likely Cause<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Reading drifts high over months<\/td>\n<td>Bearing wear reducing frictional resistance<\/td>\n<\/tr>\n<tr>\n<td>Reading drifts low over months<\/td>\n<td>Bearing wear producing binding, or debris on rotor<\/td>\n<\/tr>\n<tr>\n<td>Reading spikes at start-up<\/td>\n<td>Air or gas entrainment<\/td>\n<\/tr>\n<tr>\n<td>Reading oscillates near zero<\/td>\n<td>Cavitation or partial fill<\/td>\n<\/tr>\n<tr>\n<td>Reading disagrees with mass balance<\/td>\n<td>Inlet flow disturbance; check straight run<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Diagnostic checklists that walk from straight-run integrity \u2192 filtration \u2192 bearings \u2192 cable and signal integrity resolve most anomalies without immediate meter replacement.<\/p>\n<h2 id=\"design-practices-for-compact-skids\"><span class=\"ez-toc-section\" id=\"Design_Practices_for_Compact_Skids\"><\/span>Design Practices for Compact Skids<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Space-constrained skids often force compromises. Recommended practices:<br \/>\n&#8211; <strong>Position the <a href=\"\/tag\/turbine-meter\" target=\"_blank\"><strong>turbine meter<\/strong><\/a> as far upstream as possible<\/strong> to maximise straight-run availability.<br \/>\n&#8211; <strong>Use elbows out-of-plane<\/strong> rather than in-plane where multiple elbows precede the meter, because paired out-of-plane elbows produce less swirl.<br \/>\n&#8211; <strong>Consider a flow conditioner<\/strong> where straight run is insufficient; its pressure drop is easier to absorb than a persistent accuracy error.<br \/>\n&#8211; <strong>Install a maintenance section<\/strong> \u2014 isolation valves and a spool piece \u2014 so the meter can be removed for inspection without draining the skid.<\/p>\n<h2 id=\"shanghai-chimay-turbine-flow-meters-on-hydrogen-skids\"><span class=\"ez-toc-section\" id=\"Shanghai_ChiMay_Turbine_Flow_Meters_on_Hydrogen_Skids\"><\/span>Shanghai ChiMay Turbine Flow Meters on Hydrogen Skids<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Shanghai ChiMay turbine flow meters are specified for hydrogen feedwater skids with documented K-factors, appropriate wetted materials for feedwater service, and digital output that fits directly into the plant historian architecture. The transmitter platform matches the platform used by the plant&rsquo;s conductivity, pH and DO instruments, so operators see one HMI style and engineering maintains one spare-parts catalogue.<\/p>\n<h2 id=\"engineering-playbook\"><span class=\"ez-toc-section\" id=\"Engineering_Playbook\"><\/span>Engineering Playbook<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li>Confirm the flow range at each measurement point during process design; verify 10:1 turndown coverage.<\/li>\n<li>Preserve 10D upstream \/ 5D downstream straight runs; use a flow conditioner if space forces a compromise.<\/li>\n<li>Specify bearings and wetted materials appropriate to the service.<\/li>\n<li>Add filtration upstream where feedwater may carry debris.<\/li>\n<li>Confirm traceable calibration with points across the operating range.<\/li>\n<li>Configure digital output to feed the plant historian and digital twin.<\/li>\n<li>Establish diagnostic checklists for operator use.<\/li>\n<\/ol>\n<h2 id=\"conclusion\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Turbine flow measurement is a mature technology, but its performance on a hydrogen feedwater skid depends on how the meter is installed, calibrated and maintained. Straight-run geometry, bearing selection, wetted materials, filtration and data integration all shape the actual accuracy the plant experiences over its 25-year life. Shanghai ChiMay turbine flow meters are configured around these realities and share a transmitter platform with the rest of the plant&rsquo;s water instrumentation, giving engineering teams a coherent baseline for feedwater, cooling and blowdown flow measurement on both alkaline and PEM green hydrogen skids.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>title: &ldquo;Turbine Flow Measurement for Hydrogen Feedwater Skid Integration: Accuracy Practices from Shanghai ChiMay&rdquo; date: 2026-07-06 category: Green Hydrogen audience: Technical tags: [turbine <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a>, hydrogen skid, feedwater, flow measurement] Turbine Flow Measurement for Hydrogen Feedwater Skid Integration: Accuracy Practices from Shanghai ChiMay Key Takeaways Turbine flow meters are widely selected for hydrogen feedwater skids&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[1],"tags":[174,134481,11961],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"es","enabled_languages":["en","es","fr","ru","ar"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts\/31168"}],"collection":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/comments?post=31168"}],"version-history":[{"count":0,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/posts\/31168\/revisions"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/media?parent=31168"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/categories?post=31168"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/es\/wp-json\/wp\/v2\/tags?post=31168"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}