How to Properly Calibrate the Aster conductivity meter CT-650

Calibrating a conductivity meter is an essential step in ensuring accurate and reliable measurements. The Aster conductivity meter CT-650 is a popular choice among professionals in various industries due to its precision and ease of use. In this article, we will discuss the importance of calibration and provide a step-by-step guide on how to properly calibrate the Aster conductivity meter CT-650.

Calibration is the process of adjusting a device to ensure that it provides accurate readings. Conductivity meters measure the ability of a solution to conduct electricity, which is directly related to the concentration of ions present in the solution. Proper calibration is crucial for obtaining precise measurements and maintaining the integrity of your data.

alt-513
To calibrate the Aster conductivity meter CT-650, you will need a calibration solution with a known conductivity value. It is recommended to use at least two calibration solutions with different conductivity values to ensure accuracy. The calibration solutions should be stored properly and replaced regularly to prevent contamination and ensure consistency.

alt-514

Model pH/ORP-8500A pH/ORP Online Meter
Range pH:0.00~14.00 ; ORP:(-1999~+1999)mV; Temp.:(0.0~100.0)°C (Temp.Compensation: NTC10K)
Resolution pH:0.01 ; ORP: 1mV; Temp.:0.1°C
Accuracy pH:+/-0.1 ; ORP: +/-5mV(electronic unit); Temp.: +/-0.5°C
Temp. compensation NTC10K Temperature compensation
Medium Temp. (0~80)°C
Analog output Double channels isolated; transportable(4~20)mA, instruments/ transmitter mode
Control Output Triple channels semiconductor photoelectric switch, load current: AC/DC 30V, 50mA(max)
Communication port RS485,Modbus RTU protocol
Working Environment Temp.(0~80)℃; relative humidity <95%RH (non-condensing)
Storage Environment Temp.(-20~60)℃;Relative Humidity ≤85%RH (none condensation)
Power Supply DC 24V
Power consumption <3W
Protection level IP65 (with back cover)
Dimension 96mmx96mmx94mm(HxWxD)
Hole Size 91mmx91mm(HxW)

Before starting the calibration process, make sure that the Aster conductivity meter CT-650 is clean and free of any debris or residue. Turn on the meter and allow it to warm up for a few minutes to stabilize the readings. Once the meter is ready, immerse the probe into the first calibration solution and wait for the reading to stabilize.

To calibrate the Aster conductivity meter CT-650, navigate to the calibration menu on the device and select the appropriate calibration solution. Follow the on-screen instructions to adjust the meter to match the conductivity value of the calibration solution. Repeat this process for each calibration solution, ensuring that the readings are within the acceptable range.

After calibrating the Aster conductivity meter CT-650, rinse the probe with deionized water to remove any residue from the calibration solutions. Store the meter in a clean and dry environment to prevent damage and contamination. It is recommended to recalibrate the meter regularly to ensure accurate measurements and reliable performance.

Model pH/ORP-3500 pH/orp meter
Range pH:0.00~14.00 ; ORP: (-2000~+2000)mV; Temp.:(0.0~99.9)°C (Temp.Compensation: NTC10K)
Resolution pH:0.01 ; ORP: 1mV; Temp.:0.1°C
Accuracy pH:+/-0.1 ; ORP: +/-5mV(electronic unit); Temp.: +/-0.5°C
Temp. compensation Range: (0~120)°C; element: Pt1000
Buffer Solution 9.18; 6.86; 4.01; 10.00; 7.00; 4.00
Medium Temp. (0~50)°C (with 25°C as standard) manual/automatic temp. compensation for selection
Analog output Isolated one Channel(4~20)mA, Instrument/Transmitter for selection
Control Output Double relay output (single contact ON/OFF)
Working Environment Temp.(0~50)℃; relative humidity <95%RH (non-condensing)
Storage Environment Temp.(-20~60)℃;Relative Humidity ≤85%RH (none condensation)
Power Supply DC 24V; AC 110V; AC220V
Power consumption <3W
Dimension 48mmx96mmx80mm(HxWxD)
Hole Size 44mmx92mm(HxW)
Installation Panel mounted, fast installation

In conclusion, proper calibration is essential for maintaining the accuracy and reliability of the Aster conductivity meter CT-650. By following the steps outlined in this article, you can ensure that your meter provides precise measurements and consistent results. Remember to use high-quality calibration solutions and follow the manufacturer’s guidelines for best results. Calibrating your conductivity meter regularly will help you achieve reliable data and make informed decisions in your work.