{"id":12879,"date":"2024-04-24T11:17:45","date_gmt":"2024-04-24T03:17:45","guid":{"rendered":"https:\/\/shchimay.com\/?p=12879"},"modified":"2024-04-24T13:36:44","modified_gmt":"2024-04-24T05:36:44","slug":"ysi-dissolved-oxygen-sensor","status":"publish","type":"post","link":"https:\/\/shchimay.com\/fr\/ysi-dissolved-oxygen-sensor\/","title":{"rendered":"capteur d&#8217;oxyg\u00e8ne dissous ysi"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/fr\/ysi-dissolved-oxygen-sensor\/#Avantages_de_l%E2%80%99utilisation_du_capteur_d%E2%80%99oxygene_dissous_YSI_en_aquaculture\" title=\"Avantages de l&#8217;utilisation du capteur d&#8217;oxyg\u00e8ne dissous YSI en aquaculture\">Avantages de l&#8217;utilisation du capteur d&#8217;oxyg\u00e8ne dissous YSI en aquaculture<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/fr\/ysi-dissolved-oxygen-sensor\/#Plage_de_mesure\" title=\"Plage de mesure\">Plage de mesure<\/a><\/li><\/ul><\/nav><\/div>\n<h1 id=\"benefits-of-using-ysi-dissolved-oxygen-sensor-in-aquaculture-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Avantages_de_l%E2%80%99utilisation_du_capteur_d%E2%80%99oxygene_dissous_YSI_en_aquaculture\"><\/span>Avantages de l&#8217;utilisation du capteur d&#8217;oxyg\u00e8ne dissous YSI en aquaculture<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nMod\u00e8le d&#8217;instrument<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>FET-8920<\/td>\n<td colspan=\"2\">Plage de mesure<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">D\u00e9bit instantan\u00e9<\/td>\n<td>(0~2000)m3\/h<\/td>\n<td>D\u00e9bit cumulatif<\/td>\n<\/tr>\n<tr>\n<td>(0~99999999)m3<\/td>\n<td>D\u00e9bit<\/td>\n<\/tr>\n<tr>\n<td>(0,5~5)m\/s<\/td>\n<td>R\u00e9solution<\/td>\n<\/tr>\n<tr>\n<td>0,001m3\/h<\/td>\n<td colspan=\"2\">Niveau de pr\u00e9cision<\/td>\n<\/tr>\n<tr>\n<td>Moins de 2,5 pour cent RS ou 0,025 m\/s, selon la valeur la plus \u00e9lev\u00e9e<\/td>\n<td colspan=\"2\">Conductivit\u00e9<\/td>\n<\/tr>\n<tr>\n<td> et gt;20\u03bcS\/cm<\/td>\n<td colspan=\"2\">(4~20)sortie mA<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Nombre de voies<\/td>\n<td>Canal unique<\/td>\n<td>Caract\u00e9ristiques techniques<\/td>\n<\/tr>\n<tr>\n<td>Isol\u00e9, r\u00e9versible, r\u00e9glable, compteur\/transmission et nbsp;double mode<\/td>\n<td>R\u00e9sistance de boucle<\/td>\n<\/tr>\n<tr>\n<td>400\u03a9\uff08Max\uff09, DC 24V<\/td>\n<td>Pr\u00e9cision de transmission<\/td>\n<\/tr>\n<tr>\n<td>\u00b10,1mA<\/td>\n<td>Sortie de contr\u00f4le<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Nombre de voies<\/td>\n<td>Canal unique<\/td>\n<td>Contact \u00e9lectrique<\/td>\n<\/tr>\n<tr>\n<td>Relais photo\u00e9lectrique \u00e0 semi-conducteur<\/td>\n<td>Capacit\u00e9 de charge<\/td>\n<\/tr>\n<tr>\n<td>50mA\uff08Max\uff09, DC 30V<\/td>\n<td>Mode contr\u00f4le<\/td>\n<\/tr>\n<tr>\n<td>Alarme de limite sup\u00e9rieure\/inf\u00e9rieure de quantit\u00e9 instantan\u00e9e<\/td>\n<td>Sortie num\u00e9rique<\/td>\n<\/tr>\n<tr>\n<td>RS485 (protocole MODBUS), sortie d&#8217;impulsion 1 KHz<\/td>\n<td colspan=\"2\">Puissance de travail<\/td>\n<\/tr>\n<tr>\n<td>Alimentation<\/td>\n<td>CC 9 ~ 28 V<\/td>\n<td>source<\/td>\n<\/tr>\n<tr>\n<td>Consommation \u00e9lectrique<\/td>\n<td>\u22643.0W<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Diam\u00e8tre<\/td>\n<td>DN40 ~ DN300 (peut \u00eatre personnalis\u00e9)<\/td>\n<td>Environnement de travail<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature\u00a0:(0~50) et nbsp;\u2103; Humidit\u00e9 relative\u00a0: et nbsp\u00a0;\u00a0\u226485\u00a0pour cent d&#8217;humidit\u00e9 relative (aucune condensation)<\/td>\n<td colspan=\"2\">Environnement de stockage<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature\u00a0:(-20~60) et nbsp;\u2103; Humidit\u00e9 relative\u00a0: et nbsp\u00a0;\u00a0\u226485\u00a0pour cent d&#8217;humidit\u00e9 relative (aucune condensation)<\/td>\n<td colspan=\"2\">Degr\u00e9 de protection<\/td>\n<\/tr>\n<tr>\n<td>IP65<\/td>\n<td colspan=\"2\">M\u00e9thode d&#8217;installation<\/td>\n<\/tr>\n<tr>\n<td>Insertion et nbsp;pipeline et nbsp;installation<\/td>\n<td colspan=\"2\">L&#8217;un des principaux avantages de l&#8217;utilisation d&#8217;un capteur d&#8217;oxyg\u00e8ne dissous YSI en aquaculture est la pr\u00e9cision des donn\u00e9es qu&#8217;il fournit. Le capteur utilise une technologie de pointe pour mesurer avec pr\u00e9cision les niveaux d\u2019oxyg\u00e8ne dissous, garantissant ainsi aux aquaculteurs des informations fiables sur la sant\u00e9 de leur eau. Cette pr\u00e9cision est essentielle pour maintenir des conditions optimales pour les organismes aquatiques, car m\u00eame de petites fluctuations des niveaux d&#8217;oxyg\u00e8ne dissous peuvent avoir un impact significatif sur leur croissance et leur survie.<\/p>\n<p>En plus de leur pr\u00e9cision, les capteurs d&#8217;oxyg\u00e8ne dissous YSI sont \u00e9galement connus pour leur durabilit\u00e9 et leur fiabilit\u00e9. . Ces capteurs sont con\u00e7us pour r\u00e9sister aux conditions difficiles des environnements aquacoles, notamment l&#8217;exposition \u00e0 l&#8217;eau sal\u00e9e, aux produits chimiques et aux d\u00e9bris. Cette durabilit\u00e9 garantit que le capteur continuera \u00e0 fournir des donn\u00e9es pr\u00e9cises sur une p\u00e9riode de temps prolong\u00e9e, r\u00e9duisant ainsi le besoin d&#8217;entretien et de remplacement fr\u00e9quents.<\/p>\n<p>Un autre avantage de l&#8217;utilisation d&#8217;un capteur d&#8217;oxyg\u00e8ne dissous YSI en aquaculture est la facilit\u00e9 d&#8217;utilisation. Ces capteurs sont con\u00e7us pour \u00eatre conviviaux, avec des interfaces simples et des commandes intuitives qui les rendent faciles \u00e0 utiliser. Cette facilit\u00e9 d&#8217;utilisation permet aux aquaculteurs de surveiller rapidement et efficacement les niveaux d&#8217;oxyg\u00e8ne dissous, \u00e9conomisant ainsi du temps et des efforts dans le processus.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nComment calibrer et entretenir correctement le capteur d&#8217;oxyg\u00e8ne dissous YSI<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"IOT Meter Multi channel Controller usage\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/x9YBXoJFr6c?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>Les capteurs d&#8217;oxyg\u00e8ne dissous YSI sont des outils essentiels pour surveiller la qualit\u00e9 de l&#8217;eau dans diverses industries, notamment la surveillance de l&#8217;environnement, l&#8217;aquaculture et le traitement des eaux us\u00e9es. Ces capteurs mesurent la quantit\u00e9 d&#8217;oxyg\u00e8ne dissoute dans l&#8217;eau, ce qui est crucial pour la sant\u00e9 des organismes aquatiques et de l&#8217;\u00e9cosyst\u00e8me dans son ensemble. Pour garantir des mesures pr\u00e9cises et fiables, il est important d&#8217;\u00e9talonner et d&#8217;entretenir correctement et r\u00e9guli\u00e8rement les capteurs d&#8217;oxyg\u00e8ne dissous YSI.<\/p>\n<p>L&#8217;\u00e9talonnage est le processus d&#8217;ajustement du capteur pour mesurer avec pr\u00e9cision les niveaux d&#8217;oxyg\u00e8ne dissous dans l&#8217;eau. Cela se fait en comparant les lectures du capteur \u00e0 une norme connue, telle qu&#8217;une solution d&#8217;\u00e9talonnage avec une concentration connue d&#8217;oxyg\u00e8ne. L&#8217;\u00e9talonnage doit \u00eatre effectu\u00e9 avant chaque utilisation ou au moins une fois par mois pour garantir l&#8217;exactitude des lectures du capteur.<\/p>\n<p>Pour \u00e9talonner un capteur d&#8217;oxyg\u00e8ne dissous YSI, vous aurez besoin d&#8217;une solution d&#8217;\u00e9talonnage, d&#8217;un b\u00e9cher ou d&#8217;un r\u00e9cipient et d&#8217;un kit d&#8217;\u00e9talonnage. Commencez par remplir le r\u00e9cipient avec la solution d&#8217;\u00e9talonnage et placez le capteur dans la solution. Laissez le capteur se stabiliser pendant quelques minutes avant de prendre une lecture. Comparez la lecture du capteur \u00e0 la concentration connue d&#8217;oxyg\u00e8ne dans la solution d&#8217;\u00e9talonnage et ajustez le capteur si n\u00e9cessaire.<\/p>\n<p>En plus de l&#8217;\u00e9talonnage, il est important d&#8217;entretenir r\u00e9guli\u00e8rement les capteurs d&#8217;oxyg\u00e8ne dissous YSI pour garantir leur bon fonctionnement. Cela inclut le nettoyage du capteur apr\u00e8s chaque utilisation pour \u00e9liminer tout d\u00e9bris ou contaminant pouvant affecter la pr\u00e9cision des lectures. Utilisez une brosse ou un chiffon doux pour nettoyer d\u00e9licatement le capteur et rincez-le \u00e0 l&#8217;eau claire avant de le ranger.<\/p>\n<p>Il est \u00e9galement important de stocker correctement les capteurs d&#8217;oxyg\u00e8ne dissous YSI lorsqu&#8217;ils ne sont pas utilis\u00e9s. Rangez le capteur dans un endroit propre et sec, \u00e0 l&#8217;abri de la lumi\u00e8re directe du soleil et des temp\u00e9ratures extr\u00eames. \u00c9vitez de stocker le capteur dans un environnement humide, car cela peut entra\u00eener de la condensation \u00e0 l&#8217;int\u00e9rieur du capteur et affecter ses performances.<\/p>\n<p>\n<img decoding=\"async\" src=\"https:\/\/shchimay.com\/wp-content\/uploads\/2024\/04\/CCT-5300-2.png\" alt=\"alt-2111\" class=\"wp-image-2111\" id=\"i2111\" \/><br \/>\nInspectez r\u00e9guli\u00e8rement le capteur pour d\u00e9tecter tout signe de dommage ou d&#8217;usure, tel que des fissures ou de la corrosion. Si vous remarquez des dommages, remplacez imm\u00e9diatement le capteur pour \u00e9viter des lectures inexactes. C&#8217;est \u00e9galement une bonne id\u00e9e de tenir un journal des activit\u00e9s de maintenance et d&#8217;\u00e9talonnage du capteur pour suivre les performances du capteur au fil du temps.<\/p>\n<h1 id=\"how-to-properly-calibrate-and-maintain-ysi-dissolved-oxygen-sensor-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Plage_de_mesure\"><\/span>Plage de mesure<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nSpectrophotom\u00e9trie N,N-Di\u00e9thyl-1,4-ph\u00e9nyl\u00e8nediamine (DPD)<\/p>\n<p>\n<img decoding=\"async\" src=\"https:\/\/shchimay.com\/wp-content\/uploads\/2024\/04\/BSQ-2019-3.webp\" alt=\"alt-2121\" class=\"wp-image-2121\" id=\"i2121\" \/><br \/>\nMod\u00e8le<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>CLA-7112<\/td>\n<td colspan=\"4\">CLA-7212<\/td>\n<\/tr>\n<tr>\n<td>CLA-7113<\/td>\n<td>CLA-7213<\/td>\n<td>Canal d&#8217;entr\u00e9e<\/td>\n<td>Canal unique<\/td>\n<td>Double canal<\/td>\n<\/tr>\n<tr>\n<td>Canal unique<\/td>\n<td>Double canal<\/td>\n<td>Plage de mesure<\/td>\n<td>Chlore libre\uff1a(0,0-2,0)mg\/L, calcul\u00e9 en Cl2\u00a0;<\/td>\n<td>Chlore libre\u00a0:(0,5-10,0)mg\/L, calcul\u00e9 en Cl2\u00a0;<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">pH\uff1a\uff080-14\uff09\uff1bTemp\u00e9rature\uff1a\uff080-100\uff09\u2103<\/td>\n<td colspan=\"2\">Pr\u00e9cision<\/td>\n<td colspan=\"2\">Chlore libre\u00a0:\u00b110 pour cent ou \u00b10,05\u00a0mg\/L (prendre la grande valeur), calcul\u00e9 en Cl2\u00a0;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Chlore libre\u00a0:\u00b110 pour cent ou\u00b10,25\u00a0mg\/L (prendre la grande valeur), calcul\u00e9 en Cl2\u00a0;<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">pH\u00a0:\u00b10,1pH\uff1bTemp\u00e9rature\uff1a\u00b10,5\u2103<\/td>\n<td colspan=\"2\">P\u00e9riode de mesure<\/td>\n<td colspan=\"2\">\u22642,5min<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Intervalle d&#8217;\u00e9chantillonnage<\/td>\n<\/tr>\n<tr>\n<td>L&#8217;intervalle (1\uff5e999) min peut \u00eatre d\u00e9fini arbitrairement<\/td>\n<td colspan=\"4\">Cycle d&#8217;entretien<\/td>\n<\/tr>\n<tr>\n<td>Recommand\u00e9 une fois par mois (voir chapitre entretien)<\/td>\n<td colspan=\"4\">Exigences environnementales<\/td>\n<\/tr>\n<tr>\n<td>Une pi\u00e8ce a\u00e9r\u00e9e et s\u00e8che sans fortes vibrations\u00a0; Temp\u00e9rature ambiante recommand\u00e9e\uff1a\uff0815\uff5e28\uff09\u2103\uff1bHumidit\u00e9 relative\uff1a\u226485 pour cent \uff08Pas de condensation\uff09<\/td>\n<td colspan=\"4\">D\u00e9bit d&#8217;\u00e9chantillon d&#8217;eau<\/td>\n<\/tr>\n<tr>\n<td>\uff08200-400\uff09 ml\/min<\/td>\n<td colspan=\"4\">Pression d&#8217;entr\u00e9e<\/td>\n<\/tr>\n<tr>\n<td>\uff080.1-0.3\uff09 barre<\/td>\n<td colspan=\"4\">Plage de temp\u00e9rature de l&#8217;eau d&#8217;entr\u00e9e<\/td>\n<\/tr>\n<tr>\n<td>\uff080-40\uff09\u2103<\/td>\n<td colspan=\"4\">Alimentation<\/td>\n<\/tr>\n<tr>\n<td>CA (100-240)V\uff1b 50\/60Hz<\/td>\n<td colspan=\"4\">Puissance<\/td>\n<\/tr>\n<tr>\n<td>120W<\/td>\n<td colspan=\"4\">Connexion \u00e9lectrique<\/td>\n<\/tr>\n<tr>\n<td>Le cordon d&#8217;alimentation \u00e0 3 conducteurs avec fiche est connect\u00e9 \u00e0 la prise secteur avec un fil de terre<\/td>\n<td colspan=\"4\">Sortie de donn\u00e9es<\/td>\n<\/tr>\n<tr>\n<td>RS232\/RS485\/\uff084\uff5e20\uff09mA<\/td>\n<td colspan=\"4\">Taille<\/td>\n<\/tr>\n<tr>\n<td>H*L*P\uff1a\uff08800*400*200\uff09mm<\/td>\n<td colspan=\"4\">En conclusion, un \u00e9talonnage et un entretien appropri\u00e9s des capteurs d&#8217;oxyg\u00e8ne dissous YSI sont essentiels pour des mesures pr\u00e9cises et fiables des niveaux d&#8217;oxyg\u00e8ne dissous dans l&#8217;eau. En suivant les \u00e9tapes d\u00e9crites dans cet article, vous pouvez vous assurer que votre capteur fournit des lectures pr\u00e9cises et continue de fonctionner correctement pendant des ann\u00e9es. N&#8217;oubliez pas de calibrer le capteur avant chaque utilisation, de le nettoyer apr\u00e8s chaque utilisation, de le ranger correctement et de l&#8217;inspecter r\u00e9guli\u00e8rement pour d\u00e9celer tout signe de dommage. Avec un entretien et un entretien appropri\u00e9s, votre capteur d&#8217;oxyg\u00e8ne dissous YSI continuera d&#8217;\u00eatre un outil pr\u00e9cieux pour surveiller la qualit\u00e9 de l&#8217;eau dans diverses applications.<\/td>\n<\/tr>\n<tr>\n<td><div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-12879-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CIT-8800-Inductive-Conductivity-Concentration-Online-Controller.mp4?_=1\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CIT-8800-Inductive-Conductivity-Concentration-Online-Controller.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CIT-8800-Inductive-Conductivity-Concentration-Online-Controller.mp4<\/a><\/video><\/div><\/td>\n<td colspan=\"4\">H*W*D\uff1a\uff08800*400*200\uff09mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nIn conclusion, proper calibration and maintenance of YSI <a href=\"\/tag\/dissolved-oxygen-sensors\" target=\"_blank\"><strong>dissolved oxygen sensors<\/strong><\/a> are essential for accurate and reliable measurements of dissolved oxygen levels in water. By following the steps outlined in this article, you can ensure that your sensor provides accurate readings and continues to function properly for years to come. Remember to calibrate the sensor before each use, clean it after each use, store it properly, and regularly inspect it for any signs of damage. With proper care and maintenance, your YSI <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a> will continue to be a valuable tool for monitoring water quality in various applications.<br \/>\n<div style=\"width: 640px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-12879-2\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CIT-8800-Inductive-Conductivity-Concentration-Online-Controller.mp4?_=2\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CIT-8800-Inductive-Conductivity-Concentration-Online-Controller.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CIT-8800-Inductive-Conductivity-Concentration-Online-Controller.mp4<\/a><\/video><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Avantages de l&#8217;utilisation du capteur d&#8217;oxyg\u00e8ne dissous YSI en aquaculture Mod\u00e8le d&#8217;instrument FET-8920 Plage de mesure D\u00e9bit instantan\u00e9 (0~2000)m3\/h D\u00e9bit cumulatif (0~99999999)m3 D\u00e9bit (0,5~5)m\/s R\u00e9solution 0,001m3\/h Niveau de pr\u00e9cision Moins de 2,5 pour cent RS ou 0,025 m\/s, selon la valeur la plus \u00e9lev\u00e9e Conductivit\u00e9 et gt;20\u03bcS\/cm (4~20)sortie mA Nombre de voies Canal unique Caract\u00e9ristiques&#8230;<\/p>\n","protected":false},"author":1,"featured_media":2111,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[200],"tags":[166],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"fr","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/12879"}],"collection":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/comments?post=12879"}],"version-history":[{"count":14,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/12879\/revisions"}],"predecessor-version":[{"id":12911,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/12879\/revisions\/12911"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/media\/2111"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/media?parent=12879"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/categories?post=12879"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/tags?post=12879"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}