{"id":14137,"date":"2024-05-07T10:46:13","date_gmt":"2024-05-07T02:46:13","guid":{"rendered":"https:\/\/shchimay.com\/?p=14137"},"modified":"2024-05-07T22:26:55","modified_gmt":"2024-05-07T14:26:55","slug":"conductivity-meter-hach","status":"publish","type":"post","link":"https:\/\/shchimay.com\/fr\/conductivity-meter-hach\/","title":{"rendered":"conductim\u00e8tre hach"},"content":{"rendered":"<h1 id=\"understanding-the-importance-of-conductivity-measurement-with-hach-conductivity-meters-wpaicgheading\">Comprendre l&#8217;importance de la mesure de conductivit\u00e9 avec les conductim\u00e8tres Hach<\/h1>\n<p>\nMod\u00e8le<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/Single-Stage-RO-Controller-2.png\" alt=\"alt-962\" class=\"wp-image-962\" id=\"i962\" \/><\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Contr\u00f4leur de conductivit\u00e9\/r\u00e9sistivit\u00e9 haute pr\u00e9cision EC-8851\/EC-9900<\/td>\n<td>Plage<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">0-200\/2000\/4000\/10000uS\/cm<\/td>\n<td>0-20\/200 mS\/cm 0-18,25 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00e9cision<\/td>\n<\/tr>\n<tr>\n<td>Conductivit\u00e9\u00a0: 1,5\u00a0pour cent\u00a0; et nbsp; R\u00e9sistivit\u00e9\u00a0:\u00a02,0 pour cent (FS)<\/td>\n<td>Temp. Comp.<\/td>\n<\/tr>\n<tr>\n<td>Compensation automatique de temp\u00e9rature bas\u00e9e sur 25\u2103<\/td>\n<td>Op\u00e9ra. Temp.<\/td>\n<\/tr>\n<tr>\n<td>Normal 0\uff5e50\u2103\u00a0; Haute temp\u00e9rature 0\uff5e120\u2103<\/td>\n<td>Capteur<\/td>\n<\/tr>\n<tr>\n<td>0,01\/0,02\/0,1\/1,0\/10,0 cm<\/td>\n<td>Affichage<sup>-1<\/sup><\/td>\n<\/tr>\n<tr>\n<td>\u00c9cran LCD<\/td>\n<td>Sortie actuelle<\/td>\n<\/tr>\n<tr>\n<td>Sortie 4-20mA\/2-10V\/1-5V<\/td>\n<td>Sortie<\/td>\n<\/tr>\n<tr>\n<td>Contr\u00f4le de relais double limite haute\/basse<\/td>\n<td>Puissance<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">DC24V\/0,5A ou<\/td>\n<td>AC85-265V\u00b110 pour cent 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Environnement de travail<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Temp\u00e9rature ambiante\u00a0:0\uff5e50\u2103<\/td>\n<td>Humidit\u00e9 relative\u226485 pour cent<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<\/tr>\n<tr>\n<td>96\u00d796\u00d772mm(H\u00d7W\u00d7L)<\/td>\n<td>Taille du trou<\/td>\n<\/tr>\n<tr>\n<td>92\u00d792mm(H\u00d7W)<\/td>\n<td>Mode Installation<\/td>\n<\/tr>\n<tr>\n<td>Int\u00e9gr\u00e9<\/td>\n<td>Nom du produit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Contr\u00f4leur de transmetteur pH\/ORP-8500A<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Param\u00e8tre de mesure<\/td>\n<td colspan=\"3\">Plage de mesure<\/td>\n<\/tr>\n<tr>\n<td>Taux de r\u00e9solution<\/td>\n<td>Pr\u00e9cision<\/td>\n<td>pH<\/td>\n<td>0.00\uff5e14.00<\/td>\n<\/tr>\n<tr>\n<td>\u00b10.1<\/td>\n<td>ORP<\/td>\n<td>0.01<\/td>\n<td>(-1999\uff5e+1999)mV<\/td>\n<\/tr>\n<tr>\n<td>1mV<\/td>\n<td>\u00b15mV(Compteur \u00e9lectrique)<\/td>\n<td>Temp\u00e9rature<\/td>\n<td>(0.0\uff5e100.0)\u2103<\/td>\n<\/tr>\n<tr>\n<td>0.1\u2103<\/td>\n<td>\u00b10.5\u2103<\/td>\n<td>Plage de temp\u00e9rature de la solution test\u00e9e<\/td>\n<td>(0.0\uff5e100.0)\u2103<\/td>\n<\/tr>\n<tr>\n<td>Composante de temp\u00e9rature<\/td>\n<td colspan=\"3\">\u00c9l\u00e9ment thermique NTC10K<\/td>\n<\/tr>\n<tr>\n<td>(4~20)mA Sortie courant<\/td>\n<td colspan=\"3\">Num\u00e9ro de canal<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">2 canaux<\/td>\n<td>Caract\u00e9ristiques techniques<\/td>\n<td colspan=\"2\">Isol\u00e9, enti\u00e8rement r\u00e9glable, invers\u00e9,<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">configurable, instrument\/mode double transmission<\/td>\n<td colspan=\"2\">R\u00e9sistance de boucle<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">400\u03a9(Max)\uff0cDC 24V<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00e9cision de transmission<\/td>\n<td colspan=\"2\">\u00b10,1mA<\/td>\n<\/tr>\n<tr>\n<td>Contact de contr\u00f4le<\/td>\n<td colspan=\"2\">N\u00b0 de canal<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">3 cha\u00eenes<\/td>\n<td>Contact \u00e9lectrique<\/td>\n<td colspan=\"2\">Commutateur photo\u00e9lectrique \u00e0 semi-conducteur<\/td>\n<\/tr>\n<tr>\n<td>Programmable<\/td>\n<td colspan=\"2\">Chaque canal peut \u00eatre programm\u00e9 et pointer vers (temp\u00e9rature, pH\/ORP, temps)<\/td>\n<\/tr>\n<tr>\n<td>Caract\u00e9ristiques techniques<\/td>\n<td colspan=\"2\">Pr\u00e9r\u00e9glage de l&#8217;\u00e9tat normalement ouvert\/normalement ferm\u00e9\/impulsion\/r\u00e9gulation PID<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 de charge<\/td>\n<td colspan=\"2\">50mA(Max)AC\/DC 30V<\/td>\n<\/tr>\n<tr>\n<td>Donn\u00e9es et nbsp;communication<\/td>\n<td colspan=\"2\">MODBUS, protocole standard RS485<\/td>\n<\/tr>\n<tr>\n<td>Alimentation de travail<\/td>\n<td colspan=\"3\">CC 24V\u00b14V<\/td>\n<\/tr>\n<tr>\n<td>Consommation \u00e9lectrique globale<\/td>\n<td colspan=\"3\">5.5W<\/td>\n<\/tr>\n<tr>\n<td>Environnement de travail<\/td>\n<td colspan=\"3\">Temp\u00e9rature\u00a0: (0~50) \u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Humidit\u00e9 relative\u00a0: \u2264 85 pour cent HR (sans condensation)<\/td>\n<td colspan=\"3\">Environnement de stockage<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Temp\u00e9rature\u00a0: (-20~60) \u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Humidit\u00e9 relative\u00a0: \u2264 85 pour cent HR (sans condensation)<\/td>\n<td colspan=\"3\">Niveau de protection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">IP65 (avec cache arri\u00e8re)<\/td>\n<\/tr>\n<tr>\n<td>Taille de la forme<\/td>\n<td colspan=\"3\">96 mm\u00d796 mm\u00d794 mm (H\u00d7W\u00d7D)<\/td>\n<\/tr>\n<tr>\n<td>Taille d&#8217;ouverture<\/td>\n<td colspan=\"3\">91mm\u00d791mm(H\u00d7W)<\/td>\n<\/tr>\n<tr>\n<td>Mode fixe<\/td>\n<td colspan=\"3\">Type de montage sur panneau \u00e0 fixation rapide<\/td>\n<\/tr>\n<tr>\n<td><div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-14137-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/BSQ-2019.mp4?_=1\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/BSQ-2019.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/BSQ-2019.mp4<\/a><\/video><\/div><\/td>\n<td colspan=\"3\">En conclusion, la mesure de la conductivit\u00e9 est un param\u00e8tre critique dans diverses industries, et les conductivim\u00e8tres Hach sont con\u00e7us pour fournir des mesures pr\u00e9cises et fiables pour une large gamme d&#8217;applications. Gr\u00e2ce \u00e0 leur technologie avanc\u00e9e, leur haut niveau de pr\u00e9cision, leur large plage de mesure, leur durabilit\u00e9 et leurs fonctionnalit\u00e9s conviviales, ces compteurs sont un outil essentiel pour les industries qui s&#8217;appuient sur des mesures de conductivit\u00e9 pr\u00e9cises pour le contr\u00f4le qualit\u00e9 et l&#8217;optimisation des processus.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nIn addition to accuracy, Hach conductivity meters also offer a wide measurement range, allowing for the analysis of samples with varying conductivity levels. This versatility makes these meters suitable for a wide range of applications, from monitoring water quality in industrial processes to testing the conductivity of pharmaceutical products.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"What is On-Line Monitoring Electrical Conductivity Meter like(www.chimaytech.com)\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/M161HOnyENI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>Another important feature of Hach conductivity meters is their durability and reliability. These meters are built to withstand harsh environmental conditions and frequent use, ensuring that they provide consistent and accurate measurements over time. This reliability is essential for industries where downtime can be costly and where accurate and timely measurements are critical.<\/p>\n<p>Hach conductivity meters also offer user-friendly features that make them easy to operate and maintain. These meters are equipped with intuitive interfaces, clear displays, and simple calibration procedures, allowing users to quickly and easily obtain accurate conductivity measurements. Additionally, Hach conductivity meters are designed to be durable and easy to clean, ensuring that they remain in optimal condition for extended periods.<\/p>\n<p><div style=\"width: 640px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-14137-2\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/BSQ-2019.mp4?_=2\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/BSQ-2019.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/BSQ-2019.mp4<\/a><\/video><\/div>Overall, Hach conductivity meters are an essential tool for industries that rely on accurate conductivity measurements for quality control and process optimization. With their advanced technology, high level of accuracy, wide measurement range, durability, and user-friendly features, these meters provide users with the confidence and reliability they need to make informed decisions and ensure the quality of their products.<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/SPEC-MFC-8800-IOT-Meter-Multi-channel-Controller-8.png\" alt=\"alt-9612\" class=\"wp-image-9612\" id=\"i9612\" \/><\/p>\n<p>In conclusion, conductivity measurement is a critical parameter in various industries, and Hach conductivity meters are designed to provide accurate and reliable measurements for a wide range of applications. With their advanced technology, high level of accuracy, wide measurement range, durability, and user-friendly features, these meters are an essential tool for industries that rely on accurate conductivity measurements for quality control and process optimization.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Comprendre l&#8217;importance de la mesure de conductivit\u00e9 avec les conductim\u00e8tres Hach Mod\u00e8le Contr\u00f4leur de conductivit\u00e9\/r\u00e9sistivit\u00e9 haute pr\u00e9cision EC-8851\/EC-9900 Plage 0-200\/2000\/4000\/10000uS\/cm 0-20\/200 mS\/cm 0-18,25 M\u03a9 Pr\u00e9cision Conductivit\u00e9\u00a0: 1,5\u00a0pour cent\u00a0; et nbsp; R\u00e9sistivit\u00e9\u00a0:\u00a02,0 pour cent (FS) Temp. Comp. Compensation automatique de temp\u00e9rature bas\u00e9e sur 25\u2103 Op\u00e9ra. Temp. Normal 0\uff5e50\u2103\u00a0; Haute temp\u00e9rature 0\uff5e120\u2103 Capteur 0,01\/0,02\/0,1\/1,0\/10,0 cm Affichage-1 \u00c9cran&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1903,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[200],"tags":[158],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"fr","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/14137"}],"collection":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/comments?post=14137"}],"version-history":[{"count":14,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/14137\/revisions"}],"predecessor-version":[{"id":14304,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/14137\/revisions\/14304"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/media\/1903"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/media?parent=14137"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/categories?post=14137"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/tags?post=14137"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}