{"id":31135,"date":"2026-07-23T14:09:18","date_gmt":"2026-07-23T06:09:18","guid":{"rendered":"https:\/\/shchimay.com\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/"},"modified":"2026-07-23T14:09:18","modified_gmt":"2026-07-23T06:09:18","slug":"selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide","status":"publish","type":"post","link":"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/","title":{"rendered":"Selecting Flow Meters for Heavy-Oil Effluent Streams in Petrochemical Plants: A Shanghai ChiMay Field Guide"},"content":{"rendered":"<hr \/>\n<p>title: &ldquo;Selecting Flow Meters for Heavy-Oil Effluent Streams in Petrochemical Plants: A Shanghai ChiMay Field Guide&rdquo;<br \/>\nperspective: Purchasing<br \/>\ntheme: Oil &amp; Gas \/ Petrochemical Wastewater<br \/>\ndate: 2026-07-03<\/p>\n<hr \/>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Selecting_Flow_Meters_for_Heavy-Oil_Effluent_Streams_in_Petrochemical_Plants_A_Shanghai_ChiMay_Field_Guide\" title=\"Selecting Flow Meters for Heavy-Oil Effluent Streams in Petrochemical Plants: A Shanghai ChiMay Field Guide\">Selecting Flow Meters for Heavy-Oil Effluent Streams in Petrochemical Plants: A Shanghai ChiMay Field Guide<\/a><ul class='ez-toc-list-level-2'><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Key_Takeaways\" title=\"Key Takeaways\">Key Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Why_Heavy-Oil_Effluent_Is_a_Flow-Metering_Problem\" title=\"Why Heavy-Oil Effluent Is a Flow-Metering Problem\">Why Heavy-Oil Effluent Is a Flow-Metering Problem<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Four_Questions_Before_You_Choose_a_Technology\" title=\"Four Questions Before You Choose a Technology\">Four Questions Before You Choose a Technology<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#1_What_is_the_expected_viscosity_range_at_operating_temperature\" title=\"1. What is the expected viscosity range at operating temperature?\">1. What is the expected viscosity range at operating temperature?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#2_What_is_the_solids_loading\" title=\"2. What is the solids loading?\">2. What is the solids loading?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#3_Is_the_pipe_always_full\" title=\"3. Is the pipe always full?\">3. Is the pipe always full?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#4_What_is_the_hazardous-area_classification\" title=\"4. What is the hazardous-area classification?\">4. What is the hazardous-area classification?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Technology_Fit_Map_for_Heavy-Oil_Effluent\" title=\"Technology Fit Map for Heavy-Oil Effluent\">Technology Fit Map for Heavy-Oil Effluent<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Shanghai_ChiMay_Flow_Meters_in_Heavy-Oil_Service\" title=\"Shanghai ChiMay Flow Meters in Heavy-Oil Service\">Shanghai ChiMay Flow Meters in Heavy-Oil Service<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Comparative_Look_Wrong_Meter_vs_Right_Meter\" title=\"Comparative Look: Wrong Meter vs. Right Meter\">Comparative Look: Wrong Meter vs. Right Meter<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Installation_Practices_That_Preserve_Accuracy\" title=\"Installation Practices That Preserve Accuracy\">Installation Practices That Preserve Accuracy<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Total_Cost_of_Ownership_Frame\" title=\"Total Cost of Ownership Frame\">Total Cost of Ownership Frame<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/shchimay.com\/fr\/selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\/#Field_Guide_Summary\" title=\"Field Guide Summary\">Field Guide Summary<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 id=\"selecting-flow-meters-for-heavy-oil-effluent-streams-in-petrochemical-plants-a-shanghai-chimay-field-guide\"><span class=\"ez-toc-section\" id=\"Selecting_Flow_Meters_for_Heavy-Oil_Effluent_Streams_in_Petrochemical_Plants_A_Shanghai_ChiMay_Field_Guide\"><\/span>Selecting Flow Meters for Heavy-Oil Effluent Streams in Petrochemical Plants: A Shanghai ChiMay Field Guide<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<h2 id=\"key-takeaways\"><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>Heavy-oil effluent streams \u2014 asphaltic bottoms, slop-oil recovery, and vacuum-tower blowdown \u2014 combine variable viscosity (10\u20132,000 cP), entrained solids, and elevated temperature, defeating many general-purpose flow meters.<\/li>\n<li>Meter selection turns on four questions: viscosity range, solids loading, pipe fill condition, and hazardous-area classification.<\/li>\n<li>Paddle wheel inserted flow meters, turbine flow meters, and inline flow instruments each occupy specific application zones; no single technology covers the full heavy-oil map.<\/li>\n<li>Shanghai ChiMay paddle wheel and turbine flow meters are engineered with hydrocarbon-tolerant materials and hazardous-area options that align with petrochemical effluent service.<\/li>\n<\/ul>\n<h2 id=\"why-heavy-oil-effluent-is-a-flow-metering-problem\"><span class=\"ez-toc-section\" id=\"Why_Heavy-Oil_Effluent_Is_a_Flow-Metering_Problem\"><\/span>Why Heavy-Oil Effluent Is a Flow-Metering Problem<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Ordinary <a href=\"\/tag\/industrial-flow-meters\" target=\"_blank\"><strong>industrial flow meters<\/strong><\/a> assume a clean, low-viscosity, single-phase liquid moving through a full pipe at a predictable velocity. Heavy-oil effluent breaks every one of those assumptions. Vacuum tower drain lines run at <strong>60\u201390 \u00b0C<\/strong>, carry entrained coke fines, and shift viscosity by an order of magnitude across a normal operating day. Slop-oil recovery lines cycle between empty, air-entrained, and full states as sump pumps kick on and off.<\/p>\n<p>The result is that a &ldquo;cheap&rdquo; magnetic or vortex meter installed on the wrong line often reads badly enough that operators simply stop trusting it. Uninstrumented flows then propagate into wastewater treatment upsets, biotreater shocks, and API separator overloads. The cost of a bad meter selection is almost always paid downstream.<\/p>\n<h2 id=\"four-questions-before-you-choose-a-technology\"><span class=\"ez-toc-section\" id=\"Four_Questions_Before_You_Choose_a_Technology\"><\/span>Four Questions Before You Choose a Technology<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Petrochemical procurement engineers who consistently deliver reliable flow measurement in heavy-oil service run every candidate meter through four screening questions.<\/p>\n<h3 id=\"1-what-is-the-expected-viscosity-range-at-operating-temperature\"><span class=\"ez-toc-section\" id=\"1_What_is_the_expected_viscosity_range_at_operating_temperature\"><\/span>1. What is the expected viscosity range at operating temperature?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Under <strong>10 cP<\/strong>: electromagnetic and ultrasonic technologies are candidates (if conductivity or acoustic transparency allow). Between <strong>10 and 200 cP<\/strong>: paddle wheel and turbine designs perform reliably. Above <strong>200 cP<\/strong>: positive displacement or Coriolis meters usually win.<\/p>\n<h3 id=\"2-what-is-the-solids-loading\"><span class=\"ez-toc-section\" id=\"2_What_is_the_solids_loading\"><\/span>2. What is the solids loading?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Above roughly <strong>2% solids by volume<\/strong>, moving-part meters need to be inspected more frequently. Non-intrusive designs may fail on gas voids caused by solids-induced turbulence. Field engineers should specify a strainer or design a solids-tolerant pathway.<\/p>\n<h3 id=\"3-is-the-pipe-always-full\"><span class=\"ez-toc-section\" id=\"3_Is_the_pipe_always_full\"><\/span>3. Is the pipe always full?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Empty-pipe conditions are the number-one cause of false readings in slop-oil systems. Meters with empty-pipe detection or gravity-fed weir installations are strongly preferred where fill is uncertain.<\/p>\n<h3 id=\"4-what-is-the-hazardous-area-classification\"><span class=\"ez-toc-section\" id=\"4_What_is_the_hazardous-area_classification\"><\/span>4. What is the hazardous-area classification?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Almost all petrochemical effluent lines are Zone 1 or Zone 2. ATEX \/ IECEx \/ CSA certification for the meter body, transmitter, and cable gland is mandatory, not optional.<\/p>\n<h2 id=\"technology-fit-map-for-heavy-oil-effluent\"><span class=\"ez-toc-section\" id=\"Technology_Fit_Map_for_Heavy-Oil_Effluent\"><\/span>Technology Fit Map for Heavy-Oil Effluent<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table>\n<thead>\n<tr>\n<th>Technology<\/th>\n<th>Viscosity Sweet Spot<\/th>\n<th>Solids Tolerance<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Electromagnetic<\/td>\n<td>&lt;10 cP, conductivity &gt;5 \u00b5S\/cm<\/td>\n<td>Moderate<\/td>\n<td>Fails on non-conductive hydrocarbons<\/td>\n<\/tr>\n<tr>\n<td>Ultrasonic (clamp-on)<\/td>\n<td>&lt;50 cP<\/td>\n<td>Low<\/td>\n<td>Loses signal on entrained gas<\/td>\n<\/tr>\n<tr>\n<td>Paddle Wheel (insertion)<\/td>\n<td>10\u2013200 cP<\/td>\n<td>Moderate<\/td>\n<td>Excellent for retrofit, low pressure drop<\/td>\n<\/tr>\n<tr>\n<td>Turbine (inline)<\/td>\n<td>10\u2013150 cP<\/td>\n<td>Low<\/td>\n<td>High accuracy on clean cuts<\/td>\n<\/tr>\n<tr>\n<td>Coriolis<\/td>\n<td>1\u20135,000 cP<\/td>\n<td>Moderate<\/td>\n<td>High capex, best for custody transfer<\/td>\n<\/tr>\n<tr>\n<td>Positive Displacement<\/td>\n<td>100\u20132,000 cP<\/td>\n<td>Very low<\/td>\n<td>Requires clean fluid<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For most heavy-oil wastewater lines in refineries and petrochemical plants, <strong>paddle wheel and turbine flow meters<\/strong> deliver the best cost-to-reliability ratio in the middle viscosity band that dominates day-to-day operations.<\/p>\n<h2 id=\"shanghai-chimay-flow-meters-in-heavy-oil-service\"><span class=\"ez-toc-section\" id=\"Shanghai_ChiMay_Flow_Meters_in_Heavy-Oil_Service\"><\/span>Shanghai ChiMay Flow Meters in Heavy-Oil Service<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Shanghai ChiMay&rsquo;s paddle wheel inserted <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a> and turbine <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a> are specified for hydrocarbon exposure and hazardous-area operation from the factory.<\/p>\n<ul>\n<li><strong>Paddle Wheel Inserted <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a><\/strong> \u2014 insertion design allows retrofit without pipeline cut, tolerates moderate solids, and provides a Modbus \/ 4\u201320 mA output stream compatible with modern DCS environments.<\/li>\n<li><strong>Turbine <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a><\/strong> \u2014 high-accuracy inline option for slop-oil recovery and desalter brine cuts where the fluid is relatively clean and metering repeatability matters for mass balance.<\/li>\n<\/ul>\n<p>Both instruments can be paired with Shanghai ChiMay oil-in-water sensors and multi-parameter sensors to give operators a full picture of what is flowing, at what rate, and with what contamination profile \u2014 a much richer data set than flow alone.<\/p>\n<h2 id=\"comparative-look-wrong-meter-vs-right-meter\"><span class=\"ez-toc-section\" id=\"Comparative_Look_Wrong_Meter_vs_Right_Meter\"><\/span>Comparative Look: Wrong Meter vs. Right Meter<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table>\n<thead>\n<tr>\n<th>Attribute<\/th>\n<th>Generic Meter Retrofit<\/th>\n<th>Shanghai ChiMay Heavy-Oil Selection<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Typical error at 90 \u00b0C, 80 cP<\/td>\n<td>\u00b18\u201315%<\/td>\n<td>\u00b11.5\u20133%<\/td>\n<\/tr>\n<tr>\n<td>Cleaning interval<\/td>\n<td>1\u20133 weeks<\/td>\n<td>8\u201316 weeks<\/td>\n<\/tr>\n<tr>\n<td>Hazardous-area certification<\/td>\n<td>Optional<\/td>\n<td>ATEX \/ IECEx as standard<\/td>\n<\/tr>\n<tr>\n<td>Retrofit disruption<\/td>\n<td>Full pipeline cut<\/td>\n<td>Insertion, hot-tap compatible<\/td>\n<\/tr>\n<tr>\n<td>DCS integration<\/td>\n<td>Custom<\/td>\n<td>Standard Modbus \/ HART<\/td>\n<\/tr>\n<tr>\n<td>Life-to-failure<\/td>\n<td>12\u201324 months<\/td>\n<td>5\u20137 years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"installation-practices-that-preserve-accuracy\"><span class=\"ez-toc-section\" id=\"Installation_Practices_That_Preserve_Accuracy\"><\/span>Installation Practices That Preserve Accuracy<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Even the right meter will underperform if it is installed badly. Field-proven practices include:<\/p>\n<ul>\n<li>Provide <strong>10 diameters of straight upstream pipe and 5 diameters downstream<\/strong> for insertion and inline meters.<\/li>\n<li>Locate the meter <strong>above<\/strong> any bleed valve to avoid trapped gas at the sensing element.<\/li>\n<li>Use a <strong>strainer<\/strong> on solids-laden lines and inspect it on a defined schedule.<\/li>\n<li>Insulate and, where necessary, steam-trace lines carrying asphaltic bottoms to keep viscosity within the meter&rsquo;s sweet spot.<\/li>\n<li>Verify <strong>grounding and lightning protection<\/strong> for all field electronics in outdoor tank-farm installations.<\/li>\n<\/ul>\n<h2 id=\"total-cost-of-ownership-frame\"><span class=\"ez-toc-section\" id=\"Total_Cost_of_Ownership_Frame\"><\/span>Total Cost of Ownership Frame<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A benchmark study of North American refineries reported that operators who standardized on paddle wheel and turbine flow meters for heavy-oil effluent lines cut annual metering maintenance cost by <strong>32%<\/strong> and reduced unplanned separator upsets by roughly <strong>40%<\/strong> over a three-year window. The savings came from lower recalibration labor, fewer meter replacements, and better upstream visibility into slug flow events.<\/p>\n<p>Under a <strong>USD 55\u201375 per kilogram<\/strong> biotreater shock cost frame (typical for petrochemical wastewater), even a small reduction in upset frequency more than pays for the incremental capex of a properly specified meter.<\/p>\n<h2 id=\"field-guide-summary\"><span class=\"ez-toc-section\" id=\"Field_Guide_Summary\"><\/span>Field Guide Summary<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>Screen every candidate meter against viscosity, solids, fill condition, and hazardous-area class.<\/li>\n<li>Treat paddle wheel and turbine flow meters as the default for the 10\u2013200 cP viscosity band that dominates heavy-oil effluent lines.<\/li>\n<li>Insist on ATEX \/ IECEx certification and standard field protocols from the start.<\/li>\n<li>Pair flow meters with oil-in-water and multi-parameter sensors for a complete effluent picture.<\/li>\n<li>Shanghai ChiMay&rsquo;s paddle wheel and turbine flow meters, integrated with the broader Shanghai ChiMay <a href=\"\/tag\/water-quality-analyzer\" target=\"_blank\"><strong>water quality analyzer<\/strong><\/a> family, provide petrochemical operators with a reliable, hazardous-area-ready flow measurement foundation for heavy-oil service.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>title: &ldquo;Selecting Flow Meters for Heavy-Oil Effluent Streams in Petrochemical Plants: A Shanghai ChiMay Field Guide&rdquo; perspective: Purchasing theme: Oil &amp; Gas \/ Petrochemical Wastewater date: 2026-07-03 Selecting Flow Meters for Heavy-Oil Effluent Streams in Petrochemical Plants: A Shanghai ChiMay Field Guide Key Takeaways Heavy-oil effluent streams \u2014 asphaltic bottoms, slop-oil recovery, and vacuum-tower blowdown&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[1],"tags":[174,11427,134481,154],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"fr","enabled_languages":["en","es","fr","ru","ar"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/31135"}],"collection":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/comments?post=31135"}],"version-history":[{"count":0,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/31135\/revisions"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/media?parent=31135"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/categories?post=31135"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/tags?post=31135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}