{"id":31194,"date":"2026-07-27T23:34:21","date_gmt":"2026-07-27T15:34:21","guid":{"rendered":"https:\/\/shchimay.com\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/"},"modified":"2026-07-27T23:34:21","modified_gmt":"2026-07-27T15:34:21","slug":"how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer","status":"publish","type":"post","link":"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/","title":{"rendered":"How UV-Absorbance Techniques Support Real-Time COD Monitoring in Leachate: A Shanghai ChiMay Technical Primer"},"content":{"rendered":"<hr \/>\n<p>title: &ldquo;How UV-Absorbance Techniques Support Real-Time COD Monitoring in Leachate: A Shanghai ChiMay Technical Primer&rdquo;<br \/>\ndate: 2026-07-08<br \/>\ncategory: Landfill &amp; Waste Water<br \/>\naudience: Technical<br \/>\ntags: [UV-absorbance, COD sensor, leachate, real-time monitoring, Shanghai ChiMay]<\/p>\n<hr \/>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#How_UV-Absorbance_Techniques_Support_Real-Time_COD_Monitoring_in_Leachate_A_Shanghai_ChiMay_Technical_Primer\" title=\"How UV-Absorbance Techniques Support Real-Time COD Monitoring in Leachate: A Shanghai ChiMay Technical Primer\">How UV-Absorbance Techniques Support Real-Time COD Monitoring in Leachate: A Shanghai ChiMay Technical Primer<\/a><ul class='ez-toc-list-level-2'><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#Key_Takeaways\" title=\"Key Takeaways\">Key Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#Why_UV-Absorbance_for_COD\" title=\"Why UV-Absorbance for COD?\">Why UV-Absorbance for COD?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#The_Dual-Wavelength_Advantage\" title=\"The Dual-Wavelength Advantage\">The Dual-Wavelength Advantage<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#Handling_High-Strength_Leachate\" title=\"Handling High-Strength Leachate\">Handling High-Strength Leachate<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#Fouling_and_Optical_Window_Management\" title=\"Fouling and Optical Window Management\">Fouling and Optical Window Management<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#Correlation_With_Laboratory_COD\" title=\"Correlation With Laboratory COD\">Correlation With Laboratory COD<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#Placement_Strategy_Inside_a_Leachate_Train\" title=\"Placement Strategy Inside a Leachate Train\">Placement Strategy Inside a Leachate Train<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#Signal_Handling_and_Data_Governance\" title=\"Signal Handling and Data Governance\">Signal Handling and Data Governance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/shchimay.com\/fr\/how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 id=\"how-uv-absorbance-techniques-support-real-time-cod-monitoring-in-leachate-a-shanghai-chimay-technical-primer\"><span class=\"ez-toc-section\" id=\"How_UV-Absorbance_Techniques_Support_Real-Time_COD_Monitoring_in_Leachate_A_Shanghai_ChiMay_Technical_Primer\"><\/span>How UV-Absorbance Techniques Support Real-Time COD Monitoring in Leachate: A Shanghai ChiMay Technical Primer<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<h2 id=\"key-takeaways\"><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>UV-absorbance photometry offers a reagent-free, real-time alternative to the traditional dichromate COD wet-chemistry method, which is critical for high-organic landfill leachate loops.<\/li>\n<li>The 254 nm dual-wavelength method with turbidity compensation stays stable in leachate streams typically ranging from 8,000 to 80,000 mg\/L COD.<\/li>\n<li>Shanghai ChiMay&rsquo;s COD sensor family applies UV-absorbance techniques with adaptive path-length correction, enabling reliable readings inside biological reactors, MBR loops and pre-destruction PFAS trains.<\/li>\n<li>Understanding the underlying photonic and chemometric principles helps engineers correctly install, calibrate and validate any UV-<a href=\"\/tag\/COD-analyzer\" target=\"_blank\"><strong>COD analyzer<\/strong><\/a>, not just the Shanghai ChiMay product line.<\/li>\n<\/ul>\n<h2 id=\"why-uv-absorbance-for-cod\"><span class=\"ez-toc-section\" id=\"Why_UV-Absorbance_for_COD\"><\/span>Why UV-Absorbance for COD?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Chemical oxygen demand has historically been measured through five-day laboratory titration, requiring sulfuric acid, potassium dichromate and mercury salts. In a 2026 landfill environment, that workflow simply cannot keep pace with plants that adjust chemistry every fifteen minutes. Operators need an inline, continuous indication of organic load \u2014 one that responds within seconds, not days.<\/p>\n<p>UV-absorbance photometry solves this by exploiting a well-known physical fact: most dissolved organic matter absorbs light strongly in the 250\u2013300 nm ultraviolet region. When a beam of UV light passes through a leachate sample, the intensity that reaches the detector on the far side decreases exponentially with the concentration of absorbing species. The Beer-Lambert relationship makes this quantitative:<\/p>\n<p><code>A = \u03b5 \u00b7 c \u00b7 l<\/code><\/p>\n<p>Where A is absorbance, \u03b5 is molar absorptivity, c is concentration and l is path length. Because Beer-Lambert is a linear model over defined ranges, a well-calibrated UV sensor produces continuous COD estimates in real time.<\/p>\n<h2 id=\"the-dual-wavelength-advantage\"><span class=\"ez-toc-section\" id=\"The_Dual-Wavelength_Advantage\"><\/span>The Dual-Wavelength Advantage<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Raw leachate is optically messy. It contains humic substances, colloidal solids, colored particulates and, in some sites, pigments leached from municipal solid waste. A single-wavelength UV measurement would be constantly confused by turbidity, mistaking suspended particles for dissolved organics.<\/p>\n<p>The industry-standard solution is dual-wavelength sensing. A COD sensor uses a primary wavelength around 254 nm (highly responsive to organic matter) and a reference wavelength around 546 nm or 880 nm (mostly responsive to turbidity). The signal processor computes:<\/p>\n<p><code>A_COD = A_254 \u2013 k \u00b7 A_ref<\/code><\/p>\n<p>The correction coefficient k is empirically tuned, and Shanghai ChiMay COD sensors publish this coefficient for each factory-calibrated unit, which simplifies field re-verification. In heavy leachate, this correction can adjust the raw absorbance by 15 to 40 percent, so it is not a decorative refinement \u2014 it is the difference between a working sensor and a noisy one.<\/p>\n<h2 id=\"handling-high-strength-leachate\"><span class=\"ez-toc-section\" id=\"Handling_High-Strength_Leachate\"><\/span>Handling High-Strength Leachate<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Landfill leachate frequently exceeds 40,000 mg\/L COD, especially during rainy seasons when biodegradable organics leach from young waste layers. Photometric COD sensors have to handle this without saturating. Two mechanisms are usually combined:<\/p>\n<ul>\n<li><strong>Short optical path lengths.<\/strong> Instead of a full centimeter, the measurement gap is often reduced to 1\u20132 mm. This keeps absorbance in a linear range even at extreme concentrations.<\/li>\n<li><strong>Adaptive path selection.<\/strong> Some sensors switch between two internal path lengths depending on the observed absorbance. Shanghai ChiMay&rsquo;s newer inline <a href=\"\/tag\/COD-analyzer\" target=\"_blank\"><strong>COD analyzer<\/strong><\/a> variants support automatic path switching, which is particularly useful in equalization tanks where load swings hourly.<\/li>\n<\/ul>\n<p>Beyond hardware, the firmware performs on-the-fly chemometric regression. Multivariate calibration models trained on hundreds of leachate profiles convert absorbance into COD equivalents that align with laboratory dichromate reference values within \u00b110 percent for stable matrices and \u00b115 percent during transients.<\/p>\n<h2 id=\"fouling-and-optical-window-management\"><span class=\"ez-toc-section\" id=\"Fouling_and_Optical_Window_Management\"><\/span>Fouling and Optical Window Management<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>No UV-COD sensor survives leachate without a fouling strategy. Biofilm, oil films and inorganic scaling all attenuate the light path in ways that mimic higher COD. The countermeasures include:<\/p>\n<ul>\n<li>Automatic mechanical wipers cleaning the optical window every 15\u201360 minutes.<\/li>\n<li>Air-jet cleaning for streams with heavy suspended solids.<\/li>\n<li>Ultrasonic transducers integrated into the sensor body to prevent biofilm anchoring.<\/li>\n<li>Chemical cleaning cycles triggered by drift in the reference wavelength baseline.<\/li>\n<\/ul>\n<p>Shanghai ChiMay COD sensors intended for landfill service typically ship with a wiper module and expose window transmission as a diagnostic tag, so the plant SCADA can alarm on optical fouling before the COD reading itself becomes unreliable.<\/p>\n<h2 id=\"correlation-with-laboratory-cod\"><span class=\"ez-toc-section\" id=\"Correlation_With_Laboratory_COD\"><\/span>Correlation With Laboratory COD<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>UV-absorbance gives a <em>surrogate<\/em> COD, sometimes called UV-COD or spectroscopic COD. It is not chemically identical to dichromate COD because some organics, notably short-chain aliphatic acids, absorb weakly in UV. In practice, an operator establishes a site-specific correlation curve by pulling parallel grab samples for a few weeks. Once the correlation is captured, the online sensor reads out in &ldquo;equivalent COD&rdquo; units that regulators accept, provided the correlation is documented in the compliance file.<\/p>\n<p>Shanghai ChiMay&rsquo;s application notes for landfill leachate suggest a minimum of 20 correlation points spread over normal operating conditions plus one rainfall event.<\/p>\n<h2 id=\"placement-strategy-inside-a-leachate-train\"><span class=\"ez-toc-section\" id=\"Placement_Strategy_Inside_a_Leachate_Train\"><\/span>Placement Strategy Inside a Leachate Train<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Different points in the treatment train require different UV-COD strategies:<\/p>\n<ul>\n<li><strong>Raw leachate collection<\/strong>: extremely high absorbance, requires 1\u20132 mm path length, aggressive wiper cycles.<\/li>\n<li><strong>After equalization<\/strong>: intermediate values, 5 mm path length, standard wiper cycle.<\/li>\n<li><strong>Post-biological (anammox or nitrification)<\/strong>: lower COD, longer path lengths acceptable, correlation model retuned for different organic fingerprint.<\/li>\n<li><strong>Pre-PFAS destruction stage (foam fractionation output)<\/strong>: matrix is very different, containing surfactant residues, so a site-specific calibration is essential.<\/li>\n<\/ul>\n<p>Shanghai ChiMay recommends deploying at least two UV-COD instruments in any 2026-compliant landfill treatment plant: one upstream, one downstream of the biological stage, giving operators a real-time removal-efficiency indicator.<\/p>\n<h2 id=\"signal-handling-and-data-governance\"><span class=\"ez-toc-section\" id=\"Signal_Handling_and_Data_Governance\"><\/span>Signal Handling and Data Governance<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The April 2026 EPA rule that added nine PFAS to the RCRA hazardous constituents list also raised expectations for data integrity in leachate compliance reporting. UV-COD signals must therefore be timestamped, logged and archived. Shanghai ChiMay&rsquo;s COD sensors expose raw absorbance, corrected absorbance, temperature, window transmission and calibration ID over Modbus RTU and OPC UA, so plant historians can preserve the entire audit chain rather than just the final COD number.<\/p>\n<h2 id=\"conclusion\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>UV-absorbance is not new physics, but its combination with adaptive path length, dual-wavelength turbidity compensation and modern chemometrics has turned it into a practical, real-time COD instrument for landfill leachate. Shanghai ChiMay&rsquo;s COD sensor line demonstrates how each of these elements comes together in a form factor suited to the harsh chemistry of high-strength waste streams. For engineers designing 2026-compliant plants, understanding the underlying optics is what allows them to specify, calibrate and defend the resulting compliance data \u2014 and that is where a good technical primer earns its place.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>title: &ldquo;How UV-Absorbance Techniques Support Real-Time COD Monitoring in Leachate: A Shanghai ChiMay Technical Primer&rdquo; date: 2026-07-08 category: Landfill &amp; Waste Water audience: Technical tags: [UV-absorbance, COD sensor, leachate, real-time monitoring, Shanghai ChiMay] How UV-Absorbance Techniques Support Real-Time COD Monitoring in Leachate: A Shanghai ChiMay Technical Primer Key Takeaways UV-absorbance photometry offers a reagent-free, real-time&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[1],"tags":[11002],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"fr","enabled_languages":["en","es","fr","ru","ar"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/31194"}],"collection":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/comments?post=31194"}],"version-history":[{"count":0,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/posts\/31194\/revisions"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/media?parent=31194"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/categories?post=31194"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/fr\/wp-json\/wp\/v2\/tags?post=31194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}