Benefits of Using Flow Sensor Philips in Industrial Applications
Flow sensors are essential components in various industrial applications, as they provide accurate measurements of fluid flow rates. One of the leading manufacturers of flow sensors is Philips, known for their high-quality and reliable products. In this article, we will explore the benefits of using Flow Sensor Philips in industrial applications.
One of the key advantages of Flow Sensor Philips is their accuracy. These sensors are designed to provide precise measurements of fluid flow rates, ensuring that industrial processes run smoothly and efficiently. With Flow Sensor Philips, operators can trust that they are getting accurate data to make informed decisions about their operations.
POP-8300 free chlorine online analyzer | ||
System Model | POP-8300 free chlorine online analyzer | |
Measurement configuration | (HClO)free chlorine.. | |
total free chlorine/(ClO2)/pH/Temperature | ||
  | Free chlorine | (0.00-2.00)mg/L(ppm); (0.00-20.00)mg/L(ppm) |
Measurement | pH | 2.00-12.00 |
range | Temperature | (0.0-99.9)℃ |
  | Free chlorine | 0.01mg/L(ppm) |
Resolution | pH | 0.01 |
  | Temperature | 0.1℃ |
  | Free chlorine | Indication error 10% |
Accuracy | pH | 0.1pH |
  | Temperature | ±0.5℃ |
Sensor life | pH/free chlorine sensor | 12months(The service life is closely related to the measurement medium and maintenance frequency) |
Communication interface | RS485 | MODBUS RTU communication protocol |
  | Number of channels | Double channels |
(4-20)mA | Technical feature | Isolated, reversible, completely adjustable, instrument/transmitter dual mode |
output | Channel configuration | Programmable point to Free chlorine, chlorine dioxide, Temperature, pH |
  | Loop resistance | 400Ω(Max), DC 24V |
  | Transmission accuracy | ±0.1mA |
  | Number of channels | Double channels |
  | Contact mode | The first and second for photoelectric switch |
Control output | Load capacity | Load current 50mA(Max),AC/DC 30V |
  | Control point | Programmable function(Free chlorine, chlorine dioxide, Temperature, pH, Timing) |
  | Load capacity | Load current 50mA(Max),AC/DC 30V |
  | Control point | Programmable function(Free chlorine, chlorine dioxide, Temperature, pH, Timing) |
Power supply | Connected to electric supply | |
  | AC80-260V;50/60Hz,compatible with all international | |
  | market power standards(110V;220V;260V;50/60Hz). | |
Working environment | Temperature:(5-50)℃;relative humidity:≤85% RH(non condensation) |   |
Power Consumption | <20W | |
Storage environment | Temperature:(-20-70)℃;relative humidity:≤85%RH(non condensation) | |
Installation | Wall mounted(with the preset back cover) | |
Cabinet weight | ≤10kg | |
Cabinet dimension | 570*mm*380mm*130mm(H×W×D) |
In addition to accuracy, Flow Sensor Philips are also known for their durability. These sensors are built to withstand harsh industrial environments, including high temperatures, pressure, and corrosive substances. This durability ensures that Flow Sensor Philips can continue to provide accurate measurements over an extended period, reducing the need for frequent replacements and maintenance.
Another benefit of using Flow Sensor Philips is their versatility. These sensors can be used in a wide range of industrial applications, including water treatment, chemical processing, and oil and gas production. Whether measuring the flow of liquids or gases, Flow Sensor Philips can provide reliable data to optimize industrial processes and improve overall efficiency.
Furthermore, Flow Sensor Philips are easy to install and integrate into existing systems. With their user-friendly design and compatibility with various communication protocols, these sensors can be quickly set up and connected to industrial control systems. This ease of installation reduces downtime and allows operators to start using Flow Sensor Philips right away.
Moreover, Flow Sensor Philips are cost-effective solutions for industrial applications. By providing accurate measurements and reliable performance, these sensors help companies save money by optimizing their processes and reducing waste. With Flow Sensor Philips, operators can identify areas for improvement and make informed decisions to increase productivity and profitability.
Overall, Flow Sensor Philips offer numerous benefits for industrial applications, including accuracy, durability, versatility, ease of installation, and cost-effectiveness. These sensors are essential tools for monitoring fluid flow rates and optimizing industrial processes to improve efficiency and productivity. With Flow Sensor Philips, companies can trust that they are getting reliable data to make informed decisions and drive success in their operations.
Model | CL-810/9500 Residual Chlorine Controller |
Range | FAC/HOCL:0-10 mg/L, ATC TEMP:0-50℃ |
Accuracy | FAC/HOCL:0.1 mg/L, ATC TEMP:0.1℃ |
Oper. Temp. | 0~50℃ |
Sensor | Constant Pressure Residual Chlorine Sensor |
Waterproof Rate | IP65 |
Communication | Optional RS485 |
Output | 4-20mA output; High/Low limit double relay control |
Power | CL-810:AC 220V±10% 50/60Hz or AC 110V±10% 50/60Hz or DC24V/0.5A |
CL-9500:AC 85V-265V±10% 50/60Hz | |
Working Environment | Ambient temperature:0~50℃; |
Relative humidity≤85% | |
Dimensions | CL-810:96×96×100mm(H×W×L) |
CL-9500:96×96×132mm(H×W×L) | |
Hole Size | 92×92mm(H×W) |
Installation Mode | Embedded |