{"id":30607,"date":"2026-05-17T12:14:38","date_gmt":"2026-05-17T04:14:38","guid":{"rendered":"https:\/\/shchimay.com\/6-ways-chimay-multi-parameter-sensors-support-zld\/"},"modified":"2026-05-17T12:14:38","modified_gmt":"2026-05-17T04:14:38","slug":"6-ways-chimay-multi-parameter-sensors-support-zld","status":"publish","type":"post","link":"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/","title":{"rendered":"6 Ways ChiMay Multi-Parameter Sensors Support ZLD Monitoring"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Key_Takeaways\" title=\"Key Takeaways\">Key Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Introduction\" title=\"Introduction\">Introduction<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Understanding_Multi-Parameter_Sensing_Technology\" title=\"Understanding Multi-Parameter Sensing Technology\">Understanding Multi-Parameter Sensing Technology<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#How_Multi-Parameter_Sensors_Work\" title=\"How Multi-Parameter Sensors Work\">How Multi-Parameter Sensors Work<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Advantages_Over_Single-Parameter_Approach\" title=\"Advantages Over Single-Parameter Approach\">Advantages Over Single-Parameter Approach<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Way_1_Simplified_Brine_Concentration_Monitoring\" title=\"Way 1: Simplified Brine Concentration Monitoring\">Way 1: Simplified Brine Concentration Monitoring<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#The_Challenge\" title=\"The Challenge\">The Challenge<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#ChiMay_Solution\" title=\"ChiMay Solution\">ChiMay Solution<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#The_Challenge-2\" title=\"The Challenge\">The Challenge<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#ChiMay_Solution-2\" title=\"ChiMay Solution\">ChiMay Solution<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Installation_Benefits\" title=\"Installation Benefits\">Installation Benefits<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#ChiMay_Multi-Parameter_Sensor_Specifications\" title=\"ChiMay Multi-Parameter Sensor Specifications\">ChiMay Multi-Parameter Sensor Specifications<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Available_Parameters\" title=\"Available Parameters\">Available Parameters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Transmitter_Options\" title=\"Transmitter Options\">Transmitter Options<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Communication_Protocols\" title=\"Communication Protocols\">Communication Protocols<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Implementation_Considerations\" title=\"Implementation Considerations\">Implementation Considerations<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#System_Design\" title=\"System Design\">System Design<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Installation_Best_Practices\" title=\"Installation Best Practices\">Installation Best Practices<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Maintenance_Protocols\" title=\"Maintenance Protocols\">Maintenance Protocols<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/shchimay.com\/it\/6-ways-chimay-multi-parameter-sensors-support-zld\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>ChiMay multi-parameter sensors monitor <strong>up to 8 parameters<\/strong> from a single installation point<\/li>\n<li>Single-point multi-parameter monitoring reduces installation costs by <strong>60-75%<\/strong><\/li>\n<li>Continuous monitoring provides <strong>99.8%<\/strong> data availability for ZLD process control<\/li>\n<li>Real-time data enables <strong>35% faster response<\/strong> to process deviations<\/li>\n<li>Sensor consolidation reduces maintenance effort by <strong>40-50%<\/strong><\/li>\n<\/ul>\n<hr\/>\n<h2><span class=\"ez-toc-section\" id=\"Introduction\"><\/span>Introduction<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Zero liquid discharge (ZLD) systems represent the pinnacle of industrial water treatment, recovering all wastewater as either reusable water or solid residue. Achieving true ZLD requires comprehensive monitoring across multiple parameters throughout the treatment train\u2014often at 15-30 measurement points in a complete system.<\/p>\n<p>This fragmented monitoring approach creates complexity, cost, and maintenance burden. ChiMay multi-parameter sensors address these challenges by combining multiple measurements in single installations, simplifying ZLD monitoring while maintaining the data quality essential for reliable operation.<\/p>\n<p>This article examines six specific ways ChiMay multi-parameter sensors support ZLD monitoring applications.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Understanding_Multi-Parameter_Sensing_Technology\"><\/span>Understanding Multi-Parameter Sensing Technology<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"How_Multi-Parameter_Sensors_Work\"><\/span>How Multi-Parameter Sensors Work<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ChiMay multi-parameter sensors integrate multiple measurement technologies into unified assemblies:<\/p>\n<p><strong>Sensor Modules<\/strong>: Exchangeable sensor modules for different parameters (pH, ORP, conductivity, dissolved oxygen, turbidity, chloride, temperature) insert into common mounting hardware.<\/p>\n<p><strong>Shared Electronics<\/strong>: A single transmitter processes signals from all connected sensor modules, reducing equipment cost and complexity.<\/p>\n<p><strong>Digital Communication<\/strong>: MODBUS RTU\/TCP, HART, or Profibus communication integrates seamlessly with control systems.<\/p>\n<p><strong>Unified Data<\/strong>: All parameters report through single data acquisition system with synchronized timestamps.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Advantages_Over_Single-Parameter_Approach\"><\/span>Advantages Over Single-Parameter Approach<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table border=\"1\" cellpadding=\"5\" cellspacing=\"0\">\n<thead>\n<tr>\n<th>Metric<\/th>\n<th>Single-Parameter Sensors<\/th>\n<th>ChiMay Multi-Parameter<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Installation points<\/td>\n<td>20-30 per ZLD system<\/td>\n<td>5-10 per ZLD system<\/td>\n<\/tr>\n<tr>\n<td>Calibration effort<\/td>\n<td>20-30 calibration events\/week<\/td>\n<td>5-10 calibration events\/week<\/td>\n<\/tr>\n<tr>\n<td>Spare parts inventory<\/td>\n<td>High (many sensor types)<\/td>\n<td>Low (shared modules)<\/td>\n<\/tr>\n<tr>\n<td>Data synchronization<\/td>\n<td>Requires manual coordination<\/td>\n<td>Automatic<\/td>\n<\/tr>\n<tr>\n<td>Initial cost<\/td>\n<td>Higher<\/td>\n<td><strong>30-40% lower<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"Way_1_Simplified_Brine_Concentration_Monitoring\"><\/span>Way 1: Simplified Brine Concentration Monitoring<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"The_Challenge\"><\/span>The Challenge<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Brine concentration\u2014the heart of most ZLD systems\u2014requires multiple measurements for reliable operation:<\/p>\n<p><strong>Conductivity<\/strong>: Indicates concentration level and detects approaching saturation limits.<\/p>\n<p><strong>Temperature<\/strong>: Affects conductivity measurement and influences scaling chemistry.<\/p>\n<p><strong>pH<\/strong>: Indicates acid\/base conditions affecting carbonate scaling tendency.<\/p>\n<p><strong>Turbidity<\/strong>: Detects carryover or fouging events requiring attention.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"ChiMay_Solution\"><\/span>ChiMay Solution<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ChiMay&#39;s four-parameter sensor assembly monitors all critical brine concentration parameters from a single insertion point:<\/p>\n<h3><span class=\"ez-toc-section\" id=\"The_Challenge-2\"><\/span>The Challenge<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Large ZLD systems span extensive facilities with monitoring points separated by significant distances:<\/p>\n<p><strong>Wiring Complexity<\/strong>: Running individual signal cables from multiple points creates expensive and unreliable wiring.<\/p>\n<p><strong>Data Integration<\/strong>: Combining data from distributed locations requires additional hardware and software.<\/p>\n<p><strong>Maintenance Access<\/strong>: Remote sensor locations create maintenance challenges.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"ChiMay_Solution-2\"><\/span>ChiMay Solution<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ChiMay multi-parameter sensors with digital communication address distributed monitoring:<\/p>\n<p><strong>Bus Architecture<\/strong>: MODBUS RTU\/TCP or Profibus networks connect multiple sensors over long distances using simple wiring.<\/p>\n<p><strong>Edge Computing<\/strong>: Sensors with onboard processing perform local calculations and alarming.<\/p>\n<p><strong>Remote Configuration<\/strong>: Transmitters support remote calibration and configuration changes.<\/p>\n<p><strong>Unified Dashboard<\/strong>: Single software platform displays all monitoring points.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Installation_Benefits\"><\/span>Installation Benefits<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Distributed monitoring capabilities deliver installation advantages:<\/p>\n<ul>\n<li>Wiring cost reduction: <strong>50-70%<\/strong> compared to individual 4-20 mA loops<\/li>\n<li>Installation time reduction: <strong>40-60%<\/strong> for large systems<\/li>\n<li>Reliability improvement: <strong>Reduced wiring<\/strong> means fewer failure points<\/li>\n<li>Flexibility: Easy system expansion without extensive rewiring<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"ChiMay_Multi-Parameter_Sensor_Specifications\"><\/span>ChiMay Multi-Parameter Sensor Specifications<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Available_Parameters\"><\/span>Available Parameters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ChiMay multi-parameter systems support the following measurements:<\/p>\n<table border=\"1\" cellpadding=\"5\" cellspacing=\"0\">\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Measurement Range<\/th>\n<th>Accuracy<\/th>\n<th>Response Time<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>pH<\/td>\n<td>0-14<\/td>\n<td>\u00b10.1 pH<\/td>\n<td>&lt;5 seconds<\/td>\n<\/tr>\n<tr>\n<td>ORP<\/td>\n<td>-2000 to +2000 mV<\/td>\n<td>\u00b15 mV<\/td>\n<td>&lt;5 seconds<\/td>\n<\/tr>\n<tr>\n<td>Conductivity<\/td>\n<td>0-1,000,000 \u03bcS\/cm<\/td>\n<td>\u00b11% of reading<\/td>\n<td>&lt;2 seconds<\/td>\n<\/tr>\n<tr>\n<td>TDS<\/td>\n<td>0-500,000 mg\/L<\/td>\n<td>\u00b11% of reading<\/td>\n<td>&lt;2 seconds<\/td>\n<\/tr>\n<tr>\n<td>Dissolved Oxygen<\/td>\n<td>0-20 mg\/L<\/td>\n<td>\u00b10.2 mg\/L<\/td>\n<td>&lt;30 seconds<\/td>\n<\/tr>\n<tr>\n<td>Turbidity<\/td>\n<td>0-4000 NTU<\/td>\n<td>\u00b12% of reading<\/td>\n<td>&lt;10 seconds<\/td>\n<\/tr>\n<tr>\n<td>Temperature<\/td>\n<td>-20 to 150\u00b0C<\/td>\n<td>\u00b10.5\u00b0C<\/td>\n<td>&lt;30 seconds<\/td>\n<\/tr>\n<tr>\n<td>Chloride<\/td>\n<td>0-200,000 mg\/L<\/td>\n<td>\u00b15% of reading<\/td>\n<td>&lt;60 seconds<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span class=\"ez-toc-section\" id=\"Transmitter_Options\"><\/span>Transmitter Options<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong>Basic Transmitter<\/strong>: Single-parameter display and 4-20 mA output.<\/p>\n<p><strong>Multi-Parameter Transmitter<\/strong>: Display of up to 8 parameters with Modbus communication.<\/p>\n<p><strong>Touchscreen Transmitter<\/strong>: Color touchscreen display with data logging and Ethernet connectivity.<\/p>\n<p><strong>Remote I\/O<\/strong>: Modbus TCP\/IP enabling connection to plant control systems.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Communication_Protocols\"><\/span>Communication Protocols<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong>4-20 mA<\/strong>: Traditional analog output for single parameters<\/li>\n<li><strong>HART<\/strong>: Digital communication with analog 4-20 mA<\/li>\n<li><strong>MODBUS RTU<\/strong>: RS-485 serial communication<\/li>\n<li><strong>MODBUS TCP\/IP<\/strong>: Ethernet-based Modbus communication<\/li>\n<li><strong>Profibus<\/strong>: Industrial fieldbus communication<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Implementation_Considerations\"><\/span>Implementation Considerations<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"System_Design\"><\/span>System Design<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Proper ZLD monitoring system design ensures optimal performance:<\/p>\n<ul>\n<li><strong>Monitoring Point Identification<\/strong>: Determine all parameters requiring measurement across the ZLD system.<\/li>\n<\/ul>\n<ul>\n<li><strong>Parameter Grouping<\/strong>: Group parameters that can share installations based on location and measurement conditions.<\/li>\n<\/ul>\n<ul>\n<li><strong>Redundancy Planning<\/strong>: Critical parameters may require redundant sensors for reliability.<\/li>\n<\/ul>\n<ul>\n<li><strong>Integration Planning<\/strong>: Define control system interfaces and data management requirements.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Installation_Best_Practices\"><\/span>Installation Best Practices<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Proper installation maximizes sensor performance and longevity:<\/p>\n<ul>\n<li><strong>Accessibility<\/strong>: Position sensors for convenient calibration and maintenance access.<\/li>\n<li><strong>Sample Flow<\/strong>: Ensure adequate flow past sensor elements for representative measurement.<\/li>\n<li><strong>Environmental Protection<\/strong>: Protect sensors from direct sunlight, precipitation, and physical damage.<\/li>\n<li><strong>Calibration Access<\/strong>: Provide space and connections for calibration standards.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Maintenance_Protocols\"><\/span>Maintenance Protocols<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Regular maintenance ensures continued measurement reliability:<\/p>\n<table border=\"1\" cellpadding=\"5\" cellspacing=\"0\">\n<thead>\n<tr>\n<th>Activity<\/th>\n<th>Frequency<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Visual inspection<\/td>\n<td>Weekly<\/td>\n<\/tr>\n<tr>\n<td>Calibration verification<\/td>\n<td>Monthly<\/td>\n<\/tr>\n<tr>\n<td>Full calibration<\/td>\n<td>Quarterly<\/td>\n<\/tr>\n<tr>\n<td>Sensor cleaning<\/td>\n<td>Monthly<\/td>\n<\/tr>\n<tr>\n<td>Transmitter inspection<\/td>\n<td>Quarterly<\/td>\n<\/tr>\n<tr>\n<td>Spare parts replacement<\/td>\n<td>Annually<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>ChiMay multi-parameter sensors provide six distinct advantages for ZLD monitoring applications:<\/p>\n<ul>\n<li><strong>Simplified Brine Concentration Monitoring<\/strong>: Single installation reduces cost and maintenance.<\/li>\n<\/ul>\n<ul>\n<li><strong>Comprehensive Membrane Protection<\/strong>: Multi-parameter data protects membranes from fouling and scaling.<\/li>\n<\/ul>\n<ul>\n<li><strong>Biological Treatment Optimization<\/strong>: Combined parameters enable optimal aeration control.<\/li>\n<\/ul>\n<ul>\n<li><strong>Crystallizer and Evaporator Monitoring<\/strong>: Temperature and concentration correlation prevents equipment damage.<\/li>\n<\/ul>\n<ul>\n<li><strong>Effluent Quality Assurance<\/strong>: Comprehensive verification ensures reuse water meets specifications.<\/li>\n<\/ul>\n<ul>\n<li><strong>Remote and Distributed Monitoring<\/strong>: Digital communication simplifies large-system implementation.<\/li>\n<\/ul>\n<p>These advantages translate to measurable benefits: <strong>60-75%<\/strong> installation cost reduction, <strong>40-50%<\/strong> maintenance effort reduction, and <strong>99.8%<\/strong> data availability for process control.<\/p>\n<p>As ZLD systems become more prevalent across industries, the monitoring infrastructure supporting them must deliver reliability, simplicity, and performance. ChiMay multi-parameter sensors provide the foundation for effective ZLD monitoring while simplifying operations and reducing costs.<\/p>\n<p>Contact your ChiMay representative to discuss how multi-parameter sensing can optimize your ZLD monitoring system.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Key Takeaways ChiMay multi-parameter sensors monitor up to 8 parameters from a single installation point Single-point multi-parameter monitoring reduces installation costs by 60-75% Continuous monitoring provides 99.8% data availability for ZLD process control Real-time data enables 35% faster response to process deviations Sensor consolidation reduces maintenance effort by 40-50% Introduction Zero liquid discharge (ZLD) systems&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[1],"tags":[134481],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"it","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":false,"content":false,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"de":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"pt":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"ja":{"title":false,"content":false,"excerpt":false},"ko":{"title":false,"content":false,"excerpt":false},"it":{"title":false,"content":false,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"th":{"title":false,"content":false,"excerpt":false},"vi":{"title":false,"content":false,"excerpt":false},"tr":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/posts\/30607"}],"collection":[{"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/comments?post=30607"}],"version-history":[{"count":0,"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/posts\/30607\/revisions"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/media?parent=30607"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/categories?post=30607"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/it\/wp-json\/wp\/v2\/tags?post=30607"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}