Benefits of Using a Foodcare ph meter for Accurate Food Testing
When it comes to food safety and quality, accurate testing is essential. One tool that can greatly assist in this process is a ph meter. Specifically designed for food testing, a Foodcare ph meter is a valuable instrument that can provide precise measurements of the acidity or alkalinity of a food sample. By using a Foodcare ph meter, food manufacturers, processors, and even home cooks can ensure that their products are safe for consumption and meet the desired quality standards.
One of the key benefits of using a Foodcare ph meter is its ability to provide accurate and reliable measurements. pH is a critical parameter in food testing, as it can affect the taste, texture, and shelf life of a product. By using a Foodcare ph meter, users can quickly and easily determine the pH level of a food sample, allowing them to make informed decisions about the product’s safety and quality. This can be particularly important in industries such as dairy, meat, and beverage production, where pH levels can have a significant impact on product quality.
Model | CL-810/9500 Residual Chlorine Controller |
Range | FAC/HOCL:0-10 mg/L, ATC TEMP:0-50℃ |
Accuracy | FAC/HOCL:0.1 mg/L, ATC TEMP:0.1℃ |
Oper. Temp. | 0~50℃ |
Sensor | Constant Pressure Residual Chlorine Sensor |
Waterproof Rate | IP65 |
Communication | Optional RS485 |
Output | 4-20mA output; High/Low limit double relay control |
Power | CL-810:AC 220V±10% 50/60Hz or AC 110V±10% 50/60Hz or DC24V/0.5A |
CL-9500:AC 85V-265V±10% 50/60Hz | |
Working Environment | Ambient temperature:0~50℃; |
Relative humidity≤85% | |
Dimensions | CL-810:96×96×100mm(H×W×L) |
CL-9500:96×96×132mm(H×W×L) | |
Hole Size | 92×92mm(H×W) |
Installation Mode | Embedded |
In addition to providing accurate measurements, a Foodcare ph meter is also easy to use. With its user-friendly interface and intuitive design, even those with limited experience in food testing can quickly learn how to operate a Foodcare ph meter. This can save time and reduce the risk of errors, ensuring that accurate results are obtained with minimal effort.
Another benefit of using a Foodcare ph meter is its portability. Many models are compact and lightweight, making them easy to transport and use in various settings. Whether testing food samples in a laboratory, production facility, or even in the field, a Foodcare ph meter can provide reliable results wherever it is needed. This versatility makes it a valuable tool for food professionals who need to conduct on-the-spot testing or monitor pH levels in different locations.
ROS-8600 RO Program Control HMI Platform | ||
Model | ROS-8600 Single Stage | ROS-8600 Double Stage |
Measuring range | Source water0~2000uS/cm | Source water0~2000uS/cm |
First level effluent 0~200uS/cm | First level effluent 0~200uS/cm | |
secondary effluent 0~20uS/cm | secondary effluent 0~20uS/cm | |
Pressure sensor(optional) | Membrane pre/post pressure | Primary/ secondary membrane front/rear pressure |
ph sensor(optional) | —- | 0~14.00pH |
Signal collection | 1.Raw water low pressure | 1.Raw water low pressure |
2.Primary booster pump inlet low pressure | 2.Primary booster pump inlet low pressure | |
3.Primary booster pump outlet high pressure | 3.Primary booster pump outlet high pressure | |
4.High liquid level of Level 1 tank | 4.High liquid level of Level 1 tank | |
5.Low liquid level of Level 1 tank | 5.Low liquid level of Level 1 tank | |
6.Preprocessing signal | 6.2nd booster pump outlet high pressure | |
7.Input standby ports x2 | 7.High liquid level of Level 2 tank | |
8.Low liquid level of Level 2 tank | ||
9.Preprocessing signal | ||
10.Input standby ports x2 | ||
Output control | 1.Water inlet valve | 1.Water inlet valve |
2.Source water pump | 2.Source water pump | |
3.Primary booster pump | 3.Primary booster pump | |
4.Primary flush valve | 4.Primary flush valve | |
5.Primary dosing pump | 5.Primary dosing pump | |
6.Primary water over standard discharge valve | 6.Primary water over standard discharge valve | |
7.Alarm output node | 7.Secondary booster pump | |
8.Manual standby pump | 8.Secondary flush valve | |
9.Secondary dosing pump | 9.Secondary dosing pump | |
Output standby port x2 | 10.Secondary water over standard discharge valve | |
11.Alarm output node | ||
12.Manual standby pump | ||
Output standby port x2 | ||
The main function | 1.Correction of electrode constant | 1.Correction of electrode constant |
2.Overrun alarm setting | 2.Overrun alarm setting | |
3.All working mode time can be set | 3.All working mode time can be set | |
4.High and low pressure flushing mode setting | 4.High and low pressure flushing mode setting | |
5.The low pressure pump is opened when preprocessing | 5.The low pressure pump is opened when preprocessing | |
6.Manual/automatic can be chosen when boot up | 6.Manual/automatic can be chosen when boot up | |
7.Manual debugging mode | 7.Manual debugging mode | |
8.Alarm if communication interruption | 8.Alarm if communication interruption | |
9. Urging payment settings | 9. Urging payment settings | |
10. Company name,website can be customized | 10. Company name,website can be customized | |
Power supply | DC24V±10% | DC24V±10% |
Expansion interface | 1.Reserved relay output | 1.Reserved relay output |
2.RS485 communication | 2.RS485 communication | |
3.Reserved IO port, analog module | 3.Reserved IO port, analog module | |
4.Mobile/computer/touch screen synchronous display | 4.Mobile/computer/touch screen synchronous display | |
Relative humidity | ≦85% | ≤85% |
Environment temperature | 0~50℃ | 0~50℃ |
Touch screen size | 163x226x80mm (H x W x D) | 163x226x80mm (H x W x D) |
Hole Size | 7 inch:215*152mm(wide*high) | 215*152mm(wide*high) |
Controller size | 180*99(long*wide) | 180*99(long*wide) |
Transmitter size | 92*125(long*wide) | 92*125(long*wide) |
Installation method | Touch screen:panel embedded; Controller: plane fixed | Touch screen:panel embedded; Controller: plane fixed |
Furthermore, a Foodcare ph meter is a cost-effective solution for food testing. Compared to traditional methods such as titration, using a ph meter can save time and resources, as well as reduce the risk of human error. By investing in a Foodcare ph meter, food manufacturers and processors can streamline their testing processes and ensure consistent results across different batches of products. This can lead to improved efficiency, reduced waste, and ultimately, higher quality products for consumers.
In conclusion, the benefits of using a Foodcare ph meter for accurate food testing are clear. From providing precise measurements to being easy to use and portable, a Foodcare ph meter is a valuable tool for ensuring food safety and quality. By investing in a Foodcare ph meter, food professionals can streamline their testing processes, save time and resources, and ultimately, deliver products that meet the highest standards. Whether in a laboratory, production facility, or out in the field, a Foodcare ph meter is a reliable and cost-effective solution for accurate food testing.