Benefits of Using IFM turbidity sensor in Water Treatment Processes

Water treatment processes are essential for ensuring the safety and quality of our drinking water. One crucial aspect of water treatment is monitoring and controlling turbidity levels. Turbidity is a measure of the cloudiness or haziness of a fluid caused by suspended particles. High turbidity levels can indicate the presence of contaminants in the water, making it unsafe for consumption. To effectively monitor and control turbidity levels, water treatment facilities rely on turbidity sensors. One popular choice among water treatment professionals is the IFM turbidity sensor.

The IFM turbidity sensor is a cutting-edge device that offers numerous benefits for water treatment processes. One of the key advantages of using an IFM turbidity sensor is its accuracy. These sensors are designed to provide precise and reliable measurements of turbidity levels in real-time. This high level of accuracy allows water treatment operators to quickly detect any changes in turbidity levels and take immediate action to address any issues that may arise.

In addition to accuracy, IFM turbidity sensors are also known for their durability and reliability. These sensors are built to withstand harsh environmental conditions, making them ideal for use in water treatment facilities. Whether it’s extreme temperatures, high humidity, or exposure to chemicals, IFM turbidity sensors can continue to deliver accurate readings without any compromise in performance.

Another benefit of using an IFM turbidity sensor is its ease of installation and maintenance. These sensors are designed to be user-friendly, with simple setup procedures that require minimal training. Once installed, IFM turbidity sensors require little to no maintenance, reducing downtime and ensuring continuous monitoring of turbidity levels in the water treatment process.

alt-877
Furthermore, IFM turbidity sensors are equipped with advanced features that enhance their functionality. For example, some models come with built-in self-cleaning mechanisms that help prevent the buildup of particles on the sensor surface. This self-cleaning feature ensures that the sensor remains accurate and reliable, even in challenging operating conditions.

alt-878

The IFM turbidity sensor also offers seamless integration with existing water treatment systems. These sensors can be easily connected to control systems and data logging devices, allowing water treatment operators to monitor turbidity levels remotely and make informed decisions in real-time. This integration capability enhances the overall efficiency and effectiveness of water treatment processes, leading to improved water quality and safety.

Product name PH/ORP-6900 pH/ORP transmitter controller
Measurement parameter Measurement Range Resolution ratio Accuracy
pH 0.00~14.00 0.01 ±0.1
ORP (-1999~+1999)mV 1mV ±5mV(electric meter)
Temperature (0.0~100.0)℃ 0.1℃ ±0.5℃
Temperature range of Tested solution (0.0~100.0)℃
Temperature component Pt1000 thermal element
(4~20)mA Current output Channel No. 2 Channels
Technical characteristics Isolated, fully adjustable, reverse, configurable, instrument / transmitting dual mode
Loop resistance 400Ω(Max),DC 24V
Transmission accuracy ±0.1mA
Control contact1 Channel No 2 Channels
Electric contact Semiconductor photoelectric switch
Programmable Each channel can be programmed and point to (temperature, pH/ORP, time)
Technical characteristics Presetting of normally open / normally closed state / pulse /PID regulation
Load capacity 50mA(Max)AC/DC 30V
Control contact2 Channel No. 1 Channel
Electric contact Relay
Programmable Each channel can be programmed and point to (temperature, pH/ORP)
Technical characteristics Presetting of normally open / normally closed state / pulse /PID regulation
Load capacity 3AAC277V / 3A DC30V
Data communication RS485, MODBUS standard protocol
Working power supply AC220V±10%
Overall power consumption <9W
Working environment Temperature: (0~50) ℃ Relative humidity: ≤ 85% (non condensing)
Storage environment Temperature: (-20~60) C Relative humidity: ≤ 85% (non condensing)
Protection level IP65
Shape size 220mm×165mm×60mm (H×W×D)
Fixed mode Wall hanging type
EMC Level 3

In conclusion, the IFM turbidity sensor is a valuable tool for water treatment facilities looking to enhance their monitoring and control of turbidity levels. With its high accuracy, durability, ease of installation and maintenance, advanced features, and seamless integration capabilities, the IFM turbidity sensor offers numerous benefits that can help improve the efficiency and effectiveness of water treatment processes. By investing in an IFM turbidity sensor, water treatment operators can ensure the safety and quality of our drinking water for years to come.

FL-9900 High Precision Type Runner Flow Controller
Measuring range Frequency 0~2K Hz
Velocity of flow 0.5~5 m/s
Instantaneous flow 0~2000 m³/h
Cumulative flow 0~9999 9999.999 m³
Applicable pipe diameter range DN15~DN100;DN125~DN300
Resolution 0.01 m³/h
Refresh rate 1s
Accuracy class Level 2.0
Repeatability ±0.5%
Sensor input Radius:0~2K Hz
Supply voltage:DC 24V(instrument internal supply)
The electronic unit automatically temperature compensates for errors +0.5%FS;
4-20mA Technical characteristics Meter/transmitter dual mode (photoelectric isolation)
Loop resistance 500Q(max),DC24V;
Transmission accuracy ±0.01mA
Control port Contact mode Passive relay control output
Load capacity Load current 5A (max)
Function selection Instantaneous flow upper/lower alarm
Mains supply Working voltage: DC24V 4V Power consumption :<; 3.OW
Cable length Factory configuration: 5m, can be agreed: (1~500) m
Environmental requirement Temperature: 0~50℃; Relative humidity: ≤85%RH
Storage environment Temperature: (-20~60) ℃; Humidity: 85%RH
Overall dimension 96×96×72mm(height × width × depth)
Opening size 92×92mm
Installation mode Disc mounted, fast fixed
Sensor Body material Body: Engineering plastic PP; Bearing :Zr02 high temperature zirconia
Flow rate range 0.5~5 m/s
Withstand pressure ≤0.6MPa
Supply voltage lDC 24V
Output pulse amplitude| Vp≥8V
Normal pipe diameter DN15~DN100;DN125~DN600
Medium characteristic Single-phase medium(0~60℃)
Installation mode Direct line insertion