{"id":11255,"date":"2024-04-15T16:44:08","date_gmt":"2024-04-15T08:44:08","guid":{"rendered":"https:\/\/shchimay.com\/?p=11255"},"modified":"2024-04-16T14:46:53","modified_gmt":"2024-04-16T06:46:53","slug":"polarographic-dissolved-oxygen-sensor","status":"publish","type":"post","link":"https:\/\/shchimay.com\/ko\/polarographic-dissolved-oxygen-sensor\/","title":{"rendered":"polarographic dissolved oxygen sensor"},"content":{"rendered":"<h1 id=\"benefits-of-using-a-polarographic-dissolved-oxygen-sensor-in-water-quality-monitoring-wpaicgheading\">Benefits of Using a Polarographic <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a> in Water Quality Monitoring<\/h1>\n<p>Water quality monitoring is a crucial aspect of environmental management, as it helps to ensure the safety and health of aquatic ecosystems. One key parameter that is often monitored in water quality assessments is dissolved oxygen levels. Dissolved oxygen is essential for the survival of aquatic organisms, as it is necessary for respiration. Monitoring dissolved oxygen levels can provide valuable insights into the health of a water body and help identify potential sources of pollution.<\/p>\n<p>One of the most common methods used to measure dissolved oxygen levels is the polarographic <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a>. This sensor works on the principle of polarography, which involves measuring the current generated by the reduction of oxygen at a polarized electrode. The sensor consists of a cathode and an anode, separated by a semi-permeable membrane that allows oxygen to diffuse into the sensor.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Measuring Method<\/td>\n<td colspan=\"4\">N,N-Diethyl-1,4-phenylenediamine (DPD) spectrophotometry<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>CLA-7122<\/td>\n<td>CLA-7222<\/td>\n<td>CLA-7123<\/td>\n<td>CLA-7223<\/td>\n<\/tr>\n<tr>\n<td>Inlet water channel<\/td>\n<td>Single channel<\/td>\n<td>Dual channel<\/td>\n<td>Single channel<\/td>\n<td>Dual channel&nbsp;<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Measurement range<\/td>\n<td colspan=\"2\">Total Chlorine : (0.0 \uff5e 2.0)mg\/L ,calculated as Cl2 ;<\/td>\n<td colspan=\"2\">Total Chlorine : (0.5 \uff5e10.0)mg\/L ,calculated as Cl2 ;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">pH\uff1a\uff080-14\uff09\uff1btemperature\uff1a\uff080-100\uff09\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Accuracy<\/td>\n<td colspan=\"2\">Free chlorine: \u00b110% or 0.05mg\/L (whichever is greater), calculated as Cl2; Total chlorine: \u00b110% or 0.05mg\/L (whichever is greater), calculated as Cl2<\/td>\n<td colspan=\"2\">Free chlorine: \u00b110% or 0.25mg\/L (whichever is greater), calculated as Cl2; Total chlorine: \u00b110% or 0.25mg\/L (whichever is greater), calculated as Cl2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">pH:\u00b10.1pH\uff1bTemp.:\u00b10.5\u2103<\/td>\n<\/tr>\n<tr>\n<td>Measurement cycle<\/td>\n<td colspan=\"4\">Free Chlorine\u22642.5min<\/td>\n<\/tr>\n<tr>\n<td>Sampling interval<\/td>\n<td colspan=\"4\">The interval (1\uff5e999) min can be set to any value<\/td>\n<\/tr>\n<tr>\n<td>Maintenance cycle<\/td>\n<td colspan=\"4\">Recommended once a month (see maintenance chapter)<\/td>\n<\/tr>\n<tr>\n<td>Environmental<\/td>\n<td colspan=\"4\" rowspan=\"2\">Ventilated and dry room without strong vibration; Suggested room temperature: (15 \uff5e 28)\u2103; relative humidity: \u226485% (no condensation).<\/td>\n<\/tr>\n<tr>\n<td>requirements<\/td>\n<\/tr>\n<tr>\n<td>Sample water flow<\/td>\n<td colspan=\"4\">\uff08200-400\uff09 mL\/min<\/td>\n<\/tr>\n<tr>\n<td>inlet water pressure<\/td>\n<td colspan=\"4\">\uff080.1-0.3\uff09 bar<\/td>\n<\/tr>\n<tr>\n<td>Inlet water temperature range<\/td>\n<td colspan=\"4\">\uff080-40\uff09\u2103<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td colspan=\"4\">AC (100-240)V\uff1b 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Consumption<\/td>\n<td colspan=\"4\">120W<\/td>\n<\/tr>\n<tr>\n<td>Power connection<\/td>\n<td colspan=\"4\">3-core power cord with plug is connected to the mains socket with ground wire<\/td>\n<\/tr>\n<tr>\n<td>Data output<\/td>\n<td colspan=\"4\">RS232\/RS485\/\uff084\uff5e20\uff09mA<\/td>\n<\/tr>\n<tr>\n<td>Dimension size<\/td>\n<td colspan=\"4\">H*W*D:\uff08800*400*200\uff09mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>One of the key benefits of using a polarographic <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a> is its high accuracy and precision. The sensor can provide real-time measurements of dissolved oxygen levels with a high degree of accuracy, allowing for more reliable and consistent monitoring of water quality. This is particularly important in sensitive ecosystems where even small changes in dissolved oxygen levels can have a significant impact on aquatic organisms.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/shchimay.com\/wp-content\/uploads\/2024\/04\/pH-ORP-3500-series-pH-ORP-Online-Meter-Spec.jpg\" alt=\"alt-504\" class=\"wp-image-504\" id=\"i504\" \/><\/p>\n<p><div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-11255-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/EC-8851-\u9ad8\u7cbe\u5ea6\u7535\u5bfc\u7387\u4eea-1.mp4?_=1\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/EC-8851-\u9ad8\u7cbe\u5ea6\u7535\u5bfc\u7387\u4eea-1.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/EC-8851-\u9ad8\u7cbe\u5ea6\u7535\u5bfc\u7387\u4eea-1.mp4<\/a><\/video><\/div>In addition to its accuracy, the polarographic <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a> is also highly sensitive to changes in dissolved oxygen levels. This sensitivity allows for the detection of subtle changes in water quality, making it easier to identify potential sources of pollution or other environmental stressors. By providing continuous monitoring of dissolved oxygen levels, the sensor can help to quickly detect and respond to changes in water quality, minimizing the impact on aquatic ecosystems.<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CL-9500-Water-Quality-Test-Residual-Chlorine-Controller2-1.png\" alt=\"alt-506\" class=\"wp-image-506\" id=\"i506\" \/><\/p>\n<p>Another benefit of using a polarographic <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a> is its durability and reliability. The sensor is designed to withstand harsh environmental conditions, making it suitable for long-term monitoring in a variety of aquatic environments. Its robust construction ensures that the sensor can continue to provide accurate measurements even in challenging conditions, such as high turbidity or extreme temperatures.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"High Accuracy 4-20mA Absolute Pressure Transmitter For Liquid Gas And Steam\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/EL0pJGBee4I?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>Furthermore, the polarographic <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a> is easy to use and maintain, making it a cost-effective option for water quality monitoring. The sensor requires minimal calibration and maintenance, reducing the need for frequent adjustments or replacements. This ease of use makes the sensor ideal for both professional monitoring programs and citizen science initiatives, allowing for widespread monitoring of water quality.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\">ROC-2315 <a href=\"\/tag\/RO-Controller\" target=\"_blank\"><strong><a href=\"\/tag\/ro-controller\/\" target=\"_blank\"><strong>ro controller<\/strong><\/a><\/strong><\/a> instruction (220V)<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td colspan=\"3\">ROC-2315<\/td>\n<\/tr>\n<tr>\n<td>Single detection<\/td>\n<td rowspan=\"6\">Dry Contact input<\/td>\n<td colspan=\"2\">Raw water no water protection<\/td>\n<\/tr>\n<tr>\n<td>(six channels)<\/td>\n<td colspan=\"2\">Low-pressure protection<\/td>\n<\/tr>\n<tr>\n<td>\u3000<\/td>\n<td colspan=\"2\">High-pressure protection<\/td>\n<\/tr>\n<tr>\n<td>\u3000<\/td>\n<td colspan=\"2\">Pure water tank high&nbsp;level<\/td>\n<\/tr>\n<tr>\n<td>\u3000<\/td>\n<td colspan=\"2\">External control mode signal<\/td>\n<\/tr>\n<tr>\n<td>\u3000<\/td>\n<td colspan=\"2\">Running reset<\/td>\n<\/tr>\n<tr>\n<td>Control port<\/td>\n<td rowspan=\"5\">Dry Contact output<\/td>\n<td>Raw water pump<\/td>\n<td>SPST-NO low capacity : AC220V\/3A Max ;AC110V\/5A Max<\/td>\n<\/tr>\n<tr>\n<td>(five channels)<\/td>\n<td>Inlet valve<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>\u3000<\/td>\n<td>High pressure pump<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>\u3000<\/td>\n<td>Flush valve<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>\u3000<\/td>\n<td>Conductivity over-limit drainge valve<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Measurement detection point<\/td>\n<td colspan=\"3\">Product water conductivity and with Automatic Temperature compensation (0\uff5e50\uff09\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Measurement range<\/td>\n<td colspan=\"3\">Conductivity : 0.1~200\u03bcS\/cm\/1~2000\u03bcS\/cm\/10~999\u03bcS\/cm (with different conductivity sensor )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Product water temp. : 0~50\u2103<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"3\">1.5 level<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td colspan=\"3\">AC220V (\u00b110%)&nbsp;,&nbsp;50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Working environment<\/td>\n<td colspan=\"3\">Temperature:\uff080\uff5e50\uff09\u2103&nbsp;;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Relative Humidity :\u226485%RH&nbsp;(no condensation )<\/td>\n<\/tr>\n<tr>\n<td>Dimension<\/td>\n<td colspan=\"3\">96\u00d796\u00d7130mm( height \u00d7width\u00d7depth)<\/td>\n<\/tr>\n<tr>\n<td>Hole size<\/td>\n<td colspan=\"3\">91\u00d791mm\uff08height \u00d7width\uff09<\/td>\n<\/tr>\n<tr>\n<td>Installation<\/td>\n<td colspan=\"3\">Panel mounted ,fast installtion<\/td>\n<\/tr>\n<tr>\n<td>Certification<\/td>\n<td colspan=\"3\">CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Overall, the polarographic <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a> offers a range of benefits for water quality monitoring. Its high accuracy, sensitivity, durability, and ease of use make it a valuable tool for assessing the health of aquatic ecosystems and identifying potential sources of pollution. By providing continuous monitoring of dissolved oxygen levels, the sensor can help to protect and preserve our water resources for future generations.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Benefits of Using a Polarographic <a href=\"\/tag\/dissolved-oxygen-sensor\" target=\"_blank\"><strong>dissolved oxygen sensor<\/strong><\/a> in Water Quality Monitoring Water quality monitoring is a crucial aspect of environmental management, as it helps to ensure the safety and health of aquatic ecosystems. One key parameter that is often monitored in water quality assessments is dissolved oxygen levels. Dissolved oxygen is essential for the&#8230;<\/p>\n","protected":false},"author":1,"featured_media":3171,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[200],"tags":[166,163],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"ko","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":false,"content":false,"excerpt":false},"it":{"title":false,"content":false,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/posts\/11255"}],"collection":[{"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/comments?post=11255"}],"version-history":[{"count":11,"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/posts\/11255\/revisions"}],"predecessor-version":[{"id":11468,"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/posts\/11255\/revisions\/11468"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/media\/3171"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/media?parent=11255"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/categories?post=11255"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/ko\/wp-json\/wp\/v2\/tags?post=11255"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}