Benefits of Using HQ40D Hach for Water Quality Testing

Water quality testing is a crucial aspect of ensuring the safety and health of our water supply. With the increasing concerns about pollution and contamination, it is more important than ever to have reliable and accurate testing methods in place. One such method that has gained popularity in recent years is the use of the HQ40D Hach water quality testing instrument.

The HQ40D Hach is a portable, handheld device that allows for on-site testing of water samples. It is equipped with a variety of sensors and probes that can measure a wide range of parameters, including pH, conductivity, turbidity, and dissolved oxygen levels. This versatility makes the HQ40D Hach an invaluable tool for water quality testing in a variety of settings, from municipal water treatment plants to environmental monitoring programs.

One of the key benefits of using the HQ40D Hach is its ease of use. The device is designed to be user-friendly, with a simple interface that allows for quick and easy testing. This makes it ideal for fieldwork, where time is often of the essence. Additionally, the HQ40D Hach is lightweight and portable, making it easy to transport to different testing sites.

FL-9900 High Precision Type Runner Flow Controller
Measuring range Frequency 0~2K Hz
Velocity of flow 0.5~5 m/s
Instantaneous flow 0~2000 m³/h
Cumulative flow 0~9999 9999.999 m³
Applicable pipe diameter range DN15~DN100;DN125~DN300
Resolution 0.01 m³/h
Refresh rate 1s
Accuracy class Level 2.0
Repeatability ±0.5%
Sensor input Radius:0~2K Hz
Supply voltage:DC 24V(instrument internal supply)
The electronic unit automatically temperature compensates for errors +0.5%FS;
4-20mA Technical characteristics Meter/transmitter dual mode (photoelectric isolation)
Loop resistance 500Q(max),DC24V;
Transmission accuracy ±0.01mA
Control port Contact mode Passive relay control output
Load capacity Load current 5A (max)
Function selection Instantaneous flow upper/lower alarm
Mains supply Working voltage: DC24V 4V Power consumption :<; 3.OW
Cable length Factory configuration: 5m, can be agreed: (1~500) m
Environmental requirement Temperature: 0~50℃; Relative humidity: ≤85%RH
Storage environment Temperature: (-20~60) ℃; Humidity: 85%RH
Overall dimension 96×96×72mm(height × width × depth)
Opening size 92×92mm
Installation mode Disc mounted, fast fixed
Sensor Body material Body: Engineering plastic PP; Bearing :Zr02 high temperature zirconia
Flow rate range 0.5~5 m/s
Withstand pressure ≤0.6MPa
Supply voltage lDC 24V
Output pulse amplitude| Vp≥8V
Normal pipe diameter DN15~DN100;DN125~DN600
Medium characteristic Single-phase medium(0~60℃)
Installation mode Direct line insertion

Another advantage of the HQ40D Hach is its accuracy and reliability. The device is calibrated to ensure precise measurements, giving users confidence in the results they obtain. This is essential when making important decisions about water quality, such as determining whether a water source is safe for consumption or if additional treatment is needed.

alt-826

In addition to its accuracy, the HQ40D Hach is also known for its durability. The device is built to withstand harsh environmental conditions, making it suitable for use in a variety of settings. Whether testing water in a remote stream or a busy urban water treatment plant, the HQ40D Hach can handle the job with ease.

The HQ40D Hach also offers a high level of flexibility, with the ability to customize testing parameters to suit specific needs. This allows users to tailor their testing protocols to meet the requirements of their particular application, ensuring that they get the most relevant and useful data possible.

Overall, the HQ40D Hach is a valuable tool for anyone involved in water quality testing. Its ease of use, accuracy, reliability, durability, and flexibility make it an indispensable instrument for ensuring the safety and health of our water supply. Whether testing for regulatory compliance, environmental monitoring, or research purposes, the HQ40D Hach is a reliable and efficient choice for all your water quality testing needs.

How to Calibrate and Maintain HQ40D Hach for Accurate Results

The HQ40D Hach is a versatile and reliable instrument used for water quality testing in various industries, including environmental monitoring, wastewater treatment, and research laboratories. To ensure accurate and reliable results, it is essential to calibrate and maintain the HQ40D Hach regularly. In this article, we will discuss the importance of calibration and maintenance for the HQ40D Hach and provide a step-by-step guide on how to calibrate and maintain this instrument.

Calibration is the process of adjusting the instrument to ensure that it provides accurate and precise measurements. Regular calibration of the HQ40D Hach is crucial to maintain the instrument’s accuracy and reliability. Without proper calibration, the instrument may provide inaccurate results, leading to incorrect conclusions and decisions. To calibrate the HQ40D Hach, you will need calibration standards, such as buffer solutions or standard solutions, that are traceable to a national or international standard.

Before calibrating the HQ40D Hach, it is essential to ensure that the instrument is clean and free from any contaminants that may affect the calibration process. Clean the electrodes and sensors of the instrument using a mild detergent solution and rinse them thoroughly with deionized water. Once the instrument is clean, you can proceed with the calibration process.

To calibrate the HQ40D Hach, follow these steps:

Model NTU-1800 Online Turbidity Tester
Range 0-10/100/4000NTU or as required
Display LCD
Unit NTU
DPI 0.01
Accuracy ±5% FS
Repeatability ±1%
Power ≤3W
Power Supply AC 85V-265V±10% 50/60Hz or
DC 9~36V/0.5A
Working Environment Ambient temperature:0~50℃;
Relative humidity≤85%
Dimensions 160*80*135mm(Hanging) or 96*96mm(Embeded)
Communication 4~20mA and RS-485 communication (Modbus RTU)
Switched output Three-way relay,capacity 250VAC/5A

1. Turn on the instrument and allow it to warm up for at least 30 minutes.
2. Select the calibration mode on the instrument and follow the on-screen instructions to calibrate the electrodes and sensors.
3. Immerse the electrodes and sensors in the calibration standard solution and wait for the instrument to stabilize.

alt-8222
4. Adjust the calibration settings on the instrument until the readings match the known values of the calibration standard.
5. Rinse the electrodes and sensors with deionized water after calibration to remove any residue from the calibration standard.

After calibrating the HQ40D Hach, it is essential to perform routine maintenance to ensure the instrument’s optimal performance. Regular maintenance of the instrument will prolong its lifespan and prevent costly repairs. To maintain the HQ40D Hach, follow these maintenance tips:

1. Clean the electrodes and sensors regularly to prevent buildup of contaminants that may affect the instrument’s accuracy.
2. Check the condition of the electrodes and sensors for any signs of wear or damage and replace them if necessary.
3. Store the instrument in a clean and dry environment when not in use to prevent damage from moisture or dust.

4. Update the instrument’s firmware and software regularly to ensure that it is operating with the latest features and improvements.

By following these calibration and maintenance tips, you can ensure that your HQ40D Hach provides accurate and reliable results for your water quality testing needs. Regular calibration and maintenance of the instrument are essential to maintain its accuracy and reliability, so make sure to incorporate these practices into your routine testing procedures. With proper care and maintenance, the HQ40D Hach will continue to be a valuable tool for monitoring water quality in various industries.

Похожие записи