{"id":30839,"date":"2026-06-09T12:17:54","date_gmt":"2026-06-09T04:17:54","guid":{"rendered":"https:\/\/shchimay.com\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/"},"modified":"2026-06-09T12:17:54","modified_gmt":"2026-06-09T04:17:54","slug":"chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks","status":"publish","type":"post","link":"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/","title":{"rendered":"ChiMay Multi-Parameter Sensors: The Foundation of Smart Water Networks"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#ChiMay_Multi-Parameter_Sensors_The_Foundation_of_Smart_Water_Networks\" title=\"ChiMay Multi-Parameter Sensors: The Foundation of Smart Water Networks\">ChiMay Multi-Parameter Sensors: The Foundation of Smart Water Networks<\/a><ul class='ez-toc-list-level-2'><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Key_Takeaways\" title=\"Key Takeaways\">Key Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Introduction\" title=\"Introduction\">Introduction<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#The_Smart_Water_Network_Foundation\" title=\"The Smart Water Network Foundation\">The Smart Water Network Foundation<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Why_Multi-Parameter_Monitoring_Matters\" title=\"Why Multi-Parameter Monitoring Matters\">Why Multi-Parameter Monitoring Matters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Sensor_Count_Optimization\" title=\"Sensor Count Optimization\">Sensor Count Optimization<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Shanghai_ChiMay_4-in-1_Multi-Parameter_Sensor\" title=\"Shanghai ChiMay 4-in-1 Multi-Parameter Sensor\">Shanghai ChiMay 4-in-1 Multi-Parameter Sensor<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Measurement_Capabilities\" title=\"Measurement Capabilities\">Measurement Capabilities<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Digital_Output_Technology\" title=\"Digital Output Technology\">Digital Output Technology<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Integration_with_Smart_Water_Networks\" title=\"Integration with Smart Water Networks\">Integration with Smart Water Networks<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#SCADA_Protocol_Support\" title=\"SCADA Protocol Support\">SCADA Protocol Support<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Cloud_Connectivity\" title=\"Cloud Connectivity\">Cloud Connectivity<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Application_Examples\" title=\"Application Examples\">Application Examples<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Industrial_Wastewater_Treatment\" title=\"Industrial Wastewater Treatment\">Industrial Wastewater Treatment<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Cooling_Tower_Monitoring\" title=\"Cooling Tower Monitoring\">Cooling Tower Monitoring<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#RO_System_Monitoring\" title=\"RO System Monitoring\">RO System Monitoring<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Installation_Considerations\" title=\"Installation Considerations\">Installation Considerations<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Mounting_Options\" title=\"Mounting Options\">Mounting Options<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Environmental_Requirements\" title=\"Environmental Requirements\">Environmental Requirements<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Maintenance_and_Calibration\" title=\"Maintenance and Calibration\">Maintenance and Calibration<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Maintenance_Requirements\" title=\"Maintenance Requirements\">Maintenance Requirements<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Calibration_Procedures\" title=\"Calibration Procedures\">Calibration Procedures<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/shchimay.com\/ru\/chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 id=\"chimay-multi-parameter-sensors-the-foundation-of-smart-water-networks\"><span class=\"ez-toc-section\" id=\"ChiMay_Multi-Parameter_Sensors_The_Foundation_of_Smart_Water_Networks\"><\/span>ChiMay Multi-Parameter Sensors: The Foundation of Smart Water Networks<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<h2 id=\"key-takeaways\"><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>Multi-parameter sensors reduce deployment costs by <strong>40-60%<\/strong> compared to single-parameter installations<\/li>\n<li>Shanghai ChiMay 4-in-1 sensors measure pH, conductivity, dissolved oxygen, and turbidity simultaneously<\/li>\n<li>Digital output eliminates analog transmission errors, improving accuracy by <strong>15-20%<\/strong><\/li>\n<li>The smart water management market reaches <strong>USD 85 billion<\/strong> in 2026, growing at <strong>15% CAGR<\/strong><\/li>\n<\/ul>\n<h2 id=\"introduction\"><span class=\"ez-toc-section\" id=\"Introduction\"><\/span>Introduction<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Industrial water management increasingly demands comprehensive situational awareness. Shanghai ChiMay multi-parameter sensors consolidate multiple measurements in single devices, forming the foundation of smart water network deployments.<\/p>\n<h2 id=\"the-smart-water-network-foundation\"><span class=\"ez-toc-section\" id=\"The_Smart_Water_Network_Foundation\"><\/span>The Smart Water Network Foundation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"why-multi-parameter-monitoring-matters\"><span class=\"ez-toc-section\" id=\"Why_Multi-Parameter_Monitoring_Matters\"><\/span>Why Multi-Parameter Monitoring Matters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Understanding water quality requires multiple parameters together. <strong>Water Research Foundation (2026)<\/strong> found facilities monitoring multiple parameters together achieved <strong>25% better<\/strong> process control.<\/p>\n<h3 id=\"sensor-count-optimization\"><span class=\"ez-toc-section\" id=\"Sensor_Count_Optimization\"><\/span>Sensor Count Optimization<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Multi-parameter sensors consolidate measurements:<\/p>\n<table>\n<thead>\n<tr>\n<th>Parameters<\/th>\n<th>Traditional<\/th>\n<th>Multi-Parameter<\/th>\n<th>Reduction<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>4 parameters<\/td>\n<td>4 sensors<\/td>\n<td>1 sensor<\/td>\n<td><strong>75%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>6 parameters<\/td>\n<td>6 sensors<\/td>\n<td>2 sensors<\/td>\n<td><strong>67%<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Benefits include <strong>40-60%<\/strong> fewer installation points, simplified wiring, and maintenance efficiency.<\/p>\n<h2 id=\"shanghai-chimay-4-in-1-multi-parameter-sensor\"><span class=\"ez-toc-section\" id=\"Shanghai_ChiMay_4-in-1_Multi-Parameter_Sensor\"><\/span>Shanghai ChiMay 4-in-1 Multi-Parameter Sensor<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"measurement-capabilities\"><span class=\"ez-toc-section\" id=\"Measurement_Capabilities\"><\/span>Measurement Capabilities<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Range<\/th>\n<th>Accuracy<\/th>\n<th>Response Time<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>pH<\/td>\n<td>0-14<\/td>\n<td>\u00b10.01<\/td>\n<td>&lt; 5 seconds<\/td>\n<\/tr>\n<tr>\n<td>Conductivity<\/td>\n<td>0.1 \u03bcS\/cm &#8211; 200 mS\/cm<\/td>\n<td>\u00b10.5%<\/td>\n<td>&lt; 3 seconds<\/td>\n<\/tr>\n<tr>\n<td>Dissolved Oxygen<\/td>\n<td>0-20 mg\/L<\/td>\n<td>\u00b10.1 mg\/L<\/td>\n<td>&lt; 30 seconds<\/td>\n<\/tr>\n<tr>\n<td>Turbidity<\/td>\n<td>0-1000 NTU<\/td>\n<td>\u00b12%<\/td>\n<td>&lt; 5 seconds<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 id=\"digital-output-technology\"><span class=\"ez-toc-section\" id=\"Digital_Output_Technology\"><\/span>Digital Output Technology<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The sensor incorporates <strong>S-Digital protocol<\/strong> offering advantages over analog:<\/p>\n<ul>\n<li><strong>Elimination of analog errors<\/strong>: Digital transmission improves accuracy by <strong>15-20%<\/strong><\/li>\n<li><strong>Enhanced diagnostics<\/strong>: Bidirectional communication enables health status queries<\/li>\n<li><strong>Simplified wiring<\/strong>: Single digital cable replaces multiple analog cables<\/li>\n<li><strong>Auto-recognition<\/strong>: Automatic configuration when connected to compatible systems<\/li>\n<\/ul>\n<h2 id=\"integration-with-smart-water-networks\"><span class=\"ez-toc-section\" id=\"Integration_with_Smart_Water_Networks\"><\/span>Integration with Smart Water Networks<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"scada-protocol-support\"><span class=\"ez-toc-section\" id=\"SCADA_Protocol_Support\"><\/span>SCADA Protocol Support<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Shanghai ChiMay sensors support:<\/p>\n<ul>\n<li><strong>Modbus TCP\/IP<\/strong>: Ethernet-based communication up to <strong>10 Hz<\/strong> polling<\/li>\n<li><strong>HART<\/strong>: Combined 4-20mA analog with digital communication<\/li>\n<li><strong>4-20mA<\/strong>: Traditional analog output for compatibility<\/li>\n<li><strong>Wireless options<\/strong>: Wi-Fi, NB-IoT, or LoRaWAN via adapters<\/li>\n<\/ul>\n<h3 id=\"cloud-connectivity\"><span class=\"ez-toc-section\" id=\"Cloud_Connectivity\"><\/span>Cloud Connectivity<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>IoT-enabled sensors connect directly to cloud platforms:<\/p>\n<ul>\n<li><strong>MQTT protocol<\/strong>: Lightweight publish-subscribe architecture<\/li>\n<li><strong>Direct cloud integration<\/strong>: AWS IoT, Azure IoT Hub, Google Cloud IoT<\/li>\n<li><strong>Secure transmission<\/strong>: TLS encryption and certificate-based authentication<\/li>\n<\/ul>\n<h2 id=\"application-examples\"><span class=\"ez-toc-section\" id=\"Application_Examples\"><\/span>Application Examples<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"industrial-wastewater-treatment\"><span class=\"ez-toc-section\" id=\"Industrial_Wastewater_Treatment\"><\/span>Industrial Wastewater Treatment<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Industrial wastewater requires monitoring multiple parameters:<\/p>\n<ul>\n<li><strong>pH control<\/strong>: Precise chemical dosing for effective treatment<\/li>\n<li><strong>Conductivity tracking<\/strong>: Monitoring dissolved solids concentration<\/li>\n<li><strong>Dissolved oxygen control<\/strong>: Maintaining aerobic conditions<\/li>\n<li><strong>Turbidity monitoring<\/strong>: Indicating treatment effectiveness<\/li>\n<\/ul>\n<p>A single Shanghai ChiMay 4-in-1 sensor provides comprehensive treatment visibility.<\/p>\n<h3 id=\"cooling-tower-monitoring\"><span class=\"ez-toc-section\" id=\"Cooling_Tower_Monitoring\"><\/span>Cooling Tower Monitoring<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cooling towers require monitoring for scale, corrosion, and biofouling prevention:<\/p>\n<ul>\n<li><strong>pH monitoring<\/strong>: Maintaining optimal range (<strong>7.5-8.5<\/strong> typically)<\/li>\n<li><strong>Conductivity control<\/strong>: Managing cycles of concentration<\/li>\n<li><strong>Corrosion monitoring<\/strong>: Calculating Langelier and Ryznar indices<\/li>\n<\/ul>\n<h3 id=\"ro-system-monitoring\"><span class=\"ez-toc-section\" id=\"RO_System_Monitoring\"><\/span>RO System Monitoring<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Reverse osmosis systems require comprehensive monitoring:<\/p>\n<ul>\n<li><strong>Feedwater conductivity<\/strong>: Detecting feedwater quality changes<\/li>\n<li><strong>Permeate conductivity<\/strong>: Indicating membrane integrity<\/li>\n<li><strong>pH monitoring<\/strong>: Affecting membrane performance<\/li>\n<\/ul>\n<p>Distributed Shanghai ChiMay multi-parameter sensors enable comprehensive RO monitoring.<\/p>\n<h2 id=\"installation-considerations\"><span class=\"ez-toc-section\" id=\"Installation_Considerations\"><\/span>Installation Considerations<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"mounting-options\"><span class=\"ez-toc-section\" id=\"Mounting_Options\"><\/span>Mounting Options<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong>Insertion mounting<\/strong>: Threaded connections (<strong>1&rdquo; NPT<\/strong>, <strong>DN25<\/strong>)<\/li>\n<li><strong>Flow-through cells<\/strong>: For easy sensor access<\/li>\n<li><strong>Immersion mounting<\/strong>: Hanging into tanks or sumps<\/li>\n<li><strong>Submersible deployment<\/strong>: IP68-rated for monitoring wells<\/li>\n<\/ul>\n<h3 id=\"environmental-requirements\"><span class=\"ez-toc-section\" id=\"Environmental_Requirements\"><\/span>Environmental Requirements<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong>Temperature range<\/strong>: <strong>0\u00b0C to 60\u00b0C<\/strong> (standard), <strong>0\u00b0C to 80\u00b0C<\/strong> (high-temperature)<\/li>\n<li><strong>Pressure rating<\/strong>: <strong>6 bar<\/strong> (standard), <strong>16 bar<\/strong> (high-pressure)<\/li>\n<li><strong>Flow requirements<\/strong>: Minimum <strong>0.3 m\/s<\/strong> velocity<\/li>\n<\/ul>\n<h2 id=\"maintenance-and-calibration\"><span class=\"ez-toc-section\" id=\"Maintenance_and_Calibration\"><\/span>Maintenance and Calibration<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"maintenance-requirements\"><span class=\"ez-toc-section\" id=\"Maintenance_Requirements\"><\/span>Maintenance Requirements<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong>Cleaning<\/strong>: Weekly to monthly depending on process conditions<\/li>\n<li><strong>Membrane replacement<\/strong>: Every <strong>6-12 months<\/strong> for DO sensors<\/li>\n<li><strong>Electrolyte replacement<\/strong>: Periodic for polarographic sensors<\/li>\n<li><strong>Calibration verification<\/strong>: Monthly to quarterly<\/li>\n<\/ul>\n<h3 id=\"calibration-procedures\"><span class=\"ez-toc-section\" id=\"Calibration_Procedures\"><\/span>Calibration Procedures<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong>pH calibration<\/strong>: Two-point calibration (pH 4.0 and pH 7.0)<\/li>\n<li><strong>Conductivity calibration<\/strong>: Single-point with standard solutions<\/li>\n<li><strong>DO calibration<\/strong>: Air calibration or Winkler titration reference<\/li>\n<li><strong>Turbidity calibration<\/strong>: Formazin standard solutions<\/li>\n<\/ul>\n<p>Calibration data stores in sensor memory enabling historical tracking.<\/p>\n<h2 id=\"conclusion\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Shanghai ChiMay multi-parameter sensors provide the measurement foundation smart water networks require. Consolidating four parameters\u2014pH, conductivity, dissolved oxygen, and turbidity\u2014these sensors reduce deployment costs while delivering comprehensive visibility.<\/p>\n<p>From basic SCADA integration to advanced cloud analytics, from single-site to enterprise-wide deployment, Shanghai ChiMay multi-parameter sensors scale to meet diverse requirements. Robust construction, straightforward maintenance, and comprehensive support ensure reliable operation in demanding industrial environments.<\/p>\n<p>For facilities building smart water network infrastructure, Shanghai ChiMay multi-parameter sensors merit serious consideration.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ChiMay Multi-Parameter Sensors: The Foundation of Smart Water Networks Key Takeaways Multi-parameter sensors reduce deployment costs by 40-60% compared to single-parameter installations Shanghai ChiMay 4-in-1 sensors measure pH, conductivity, dissolved oxygen, and turbidity simultaneously Digital output eliminates analog transmission errors, improving accuracy by 15-20% The smart water management market reaches USD 85 billion in 2026,&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[1],"tags":[],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"ru","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":false,"content":false,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"de":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"pt":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"ja":{"title":false,"content":false,"excerpt":false},"ko":{"title":false,"content":false,"excerpt":false},"it":{"title":false,"content":false,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"th":{"title":false,"content":false,"excerpt":false},"vi":{"title":false,"content":false,"excerpt":false},"tr":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/posts\/30839"}],"collection":[{"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/comments?post=30839"}],"version-history":[{"count":0,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/posts\/30839\/revisions"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/media?parent=30839"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/categories?post=30839"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/tags?post=30839"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}