{"id":31228,"date":"2026-08-02T21:41:14","date_gmt":"2026-08-02T13:41:14","guid":{"rendered":"https:\/\/shchimay.com\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/"},"modified":"2026-08-02T21:41:14","modified_gmt":"2026-08-02T13:41:14","slug":"inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay","status":"publish","type":"post","link":"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/","title":{"rendered":"Inside a Modern ZLD Plant: The Sensor Cluster That Closes the Water Loop with Shanghai ChiMay"},"content":{"rendered":"<hr \/>\n<p>title: &ldquo;Inside a Modern ZLD Plant: The Sensor Cluster That Closes the Water Loop with Shanghai ChiMay&rdquo;<br \/>\ndate: 2026-07-10<br \/>\ncategory: Zero Liquid Discharge &amp; Water Circularity<br \/>\naudience: Operations Managers &amp; Instrument Engineers<br \/>\ntags: [ZLD, sensor cluster, water loop, digital twin, Shanghai ChiMay]<\/p>\n<hr \/>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Inside_a_Modern_ZLD_Plant_The_Sensor_Cluster_That_Closes_the_Water_Loop_with_Shanghai_ChiMay\" title=\"Inside a Modern ZLD Plant: The Sensor Cluster That Closes the Water Loop with Shanghai ChiMay\">Inside a Modern ZLD Plant: The Sensor Cluster That Closes the Water Loop with Shanghai ChiMay<\/a><ul class='ez-toc-list-level-2'><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Key_Takeaways\" title=\"Key Takeaways\">Key Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#A_Tour_of_the_Plant\" title=\"A Tour of the Plant\">A Tour of the Plant<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Stage_1_Feed_Intake_and_Equalisation\" title=\"Stage 1: Feed Intake and Equalisation\">Stage 1: Feed Intake and Equalisation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Stage_2_Softener_and_Pretreatment\" title=\"Stage 2: Softener and Pretreatment\">Stage 2: Softener and Pretreatment<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Stage_3_Membrane_Concentration_RO_and_NF\" title=\"Stage 3: Membrane Concentration (RO and NF)\">Stage 3: Membrane Concentration (RO and NF)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Stage_4_Brine_Concentration_MVR_Evaporator\" title=\"Stage 4: Brine Concentration (MVR \/ Evaporator)\">Stage 4: Brine Concentration (MVR \/ Evaporator)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Stage_5_Crystallisation\" title=\"Stage 5: Crystallisation\">Stage 5: Crystallisation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Stage_6_Solids_Handling\" title=\"Stage 6: Solids Handling\">Stage 6: Solids Handling<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Stage_7_Distillate_and_Reuse\" title=\"Stage 7: Distillate and Reuse\">Stage 7: Distillate and Reuse<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Stage_8_Utilities_and_Auxiliaries\" title=\"Stage 8: Utilities and Auxiliaries\">Stage 8: Utilities and Auxiliaries<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#The_Digital_Twin_Layer\" title=\"The Digital Twin Layer\">The Digital Twin Layer<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Instrumentation_Coverage_Metric\" title=\"Instrumentation Coverage Metric\">Instrumentation Coverage Metric<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#What_Retrofit_Teams_Change_First\" title=\"What Retrofit Teams Change First\">What Retrofit Teams Change First<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/shchimay.com\/ru\/inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\/#Closing_Note\" title=\"Closing Note\">Closing Note<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 id=\"inside-a-modern-zld-plant-the-sensor-cluster-that-closes-the-water-loop-with-shanghai-chimay\"><span class=\"ez-toc-section\" id=\"Inside_a_Modern_ZLD_Plant_The_Sensor_Cluster_That_Closes_the_Water_Loop_with_Shanghai_ChiMay\"><\/span>Inside a Modern ZLD Plant: The Sensor Cluster That Closes the Water Loop with Shanghai ChiMay<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<h2 id=\"key-takeaways\"><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>A modern Zero Liquid Discharge plant relies on a coordinated cluster of roughly 60\u201390 sensors distributed across pretreatment, membrane concentration, evaporation, crystallisation and reuse loops.<\/li>\n<li>No single sensor makes ZLD work; the cluster does, because each unit operation depends on the others reporting reliable data continuously.<\/li>\n<li>Instrumentation coverage above 90% on process-critical streams is now the benchmark for a defensible ZLD asset, and gaps below that level correlate strongly with missed availability.<\/li>\n<li>Shanghai ChiMay&rsquo;s <a href=\"\/tag\/water-quality-analyzer\" target=\"_blank\"><strong>water quality analyzer<\/strong><\/a> family and <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> platform provide the sensor cluster&rsquo;s backbone, from softener outlet through crystalliser mother liquor.<\/li>\n<\/ul>\n<h2 id=\"a-tour-of-the-plant\"><span class=\"ez-toc-section\" id=\"A_Tour_of_the_Plant\"><\/span>A Tour of the Plant<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Walking a modern ZLD plant from feed intake to solid product discharge, an instrument engineer sees roughly 60\u201390 process sensors, plus another 30\u201350 utility sensors. The instrument density is roughly triple that of a conventional wastewater plant, and every one of those signals is doing a job. This article walks the plant stage by stage, listing the sensors that actually decide performance.<\/p>\n<h2 id=\"stage-1-feed-intake-and-equalisation\"><span class=\"ez-toc-section\" id=\"Stage_1_Feed_Intake_and_Equalisation\"><\/span>Stage 1: Feed Intake and Equalisation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The intake is where feed characterisation earns its keep. Sensors typically installed here:<\/p>\n<ul>\n<li>Turbine <a href=\"\/tag\/flow-meter\/\" target=\"_blank\"><strong>flow meter<\/strong><\/a> on each intake source.<\/li>\n<li>Multi-parameter sensor on the equalisation tank: pH, conductivity, temperature, ORP.<\/li>\n<li><a href=\"\/tag\/Turbidity-Tester\" target=\"_blank\"><strong>Turbidity Tester<\/strong><\/a> at the equalisation outlet.<\/li>\n<li>Oil-in-water sensor on any stream expected to carry hydrocarbons.<\/li>\n<\/ul>\n<p>The purpose of this cluster is to trigger the correct downstream operating envelope and to catch feed excursions before they cascade.<\/p>\n<h2 id=\"stage-2-softener-and-pretreatment\"><span class=\"ez-toc-section\" id=\"Stage_2_Softener_and_Pretreatment\"><\/span>Stage 2: Softener and Pretreatment<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Pretreatment removes hardness, particulates and, where relevant, iron and manganese. Sensors around this stage:<\/p>\n<ul>\n<li><a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> (Shanghai ChiMay <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a>) with integrated cycle counters, service and regeneration status.<\/li>\n<li>Hardness monitor on the softened water outlet.<\/li>\n<li><a href=\"\/tag\/Conductivity-Meter\" target=\"_blank\"><strong><a href=\"\/tag\/conductivity-meter\/\" target=\"_blank\"><strong>conductivity meter<\/strong><\/a><\/strong><\/a> on the softened water outlet.<\/li>\n<li>Differential pressure across the softener bed.<\/li>\n<li>Free-chlorine (residual chlorine transmitter) upstream to protect resin from oxidants.<\/li>\n<\/ul>\n<p>This cluster confirms that pretreatment is delivering the feed quality the downstream RO train requires.<\/p>\n<h2 id=\"stage-3-membrane-concentration-ro-and-nf\"><span class=\"ez-toc-section\" id=\"Stage_3_Membrane_Concentration_RO_and_NF\"><\/span>Stage 3: Membrane Concentration (RO and NF)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Reverse osmosis and nanofiltration produce the first significant concentration. Sensors here:<\/p>\n<ul>\n<li>Feed conductivity, permeate conductivity, reject conductivity for each stage.<\/li>\n<li>Feed pH and reject pH.<\/li>\n<li>Feed and reject flow.<\/li>\n<li>Differential pressure across each stage.<\/li>\n<li>Turbidity on RO feed to catch pretreatment excursions in real time.<\/li>\n<\/ul>\n<p>Recovery is monitored continuously and alarmed if it drifts more than 5% over 24 hours.<\/p>\n<h2 id=\"stage-4-brine-concentration-mvr-evaporator\"><span class=\"ez-toc-section\" id=\"Stage_4_Brine_Concentration_MVR_Evaporator\"><\/span>Stage 4: Brine Concentration (MVR \/ Evaporator)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The brine concentrator moves the stream to 60\u2013120 mS\/cm. Sensors:<\/p>\n<ul>\n<li>Toroidal <a href=\"\/tag\/Conductivity-Meter\" target=\"_blank\"><strong><a href=\"\/tag\/conductivity-meter\/\" target=\"_blank\"><strong>conductivity meter<\/strong><\/a><\/strong><\/a> on the recirculation line.<\/li>\n<li>Multi-parameter sensor (pH, ORP, temperature) on the recirculation loop.<\/li>\n<li>Differential pressure across the heat exchanger.<\/li>\n<li>Level transmitter on the sump.<\/li>\n<li>Flow meters on the feed, recycle and vapour lines.<\/li>\n<li>Suspended solids sensor on the reject recirculation line to detect flocculent build-up.<\/li>\n<\/ul>\n<p>This is the highest-value instrumentation cluster in the plant; scale-related evaporator washes typically cost USD 80,000 per event, so redundant coverage is common.<\/p>\n<h2 id=\"stage-5-crystallisation\"><span class=\"ez-toc-section\" id=\"Stage_5_Crystallisation\"><\/span>Stage 5: Crystallisation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Crystallisation is the safety-critical stage where off-spec batches cascade into revenue loss. Sensors:<\/p>\n<ul>\n<li>Two conductivity heads on the feed line, independently calibrated (Shanghai ChiMay in-line <a href=\"\/tag\/Conductivity-Meter\" target=\"_blank\"><strong><a href=\"\/tag\/conductivity-meter\/\" target=\"_blank\"><strong>conductivity meter<\/strong><\/a><\/strong><\/a>, toroidal).<\/li>\n<li>Two pH electrodes on the feed line, double-junction, independently calibrated.<\/li>\n<li>ORP electrode on the mother liquor.<\/li>\n<li>Level and temperature transmitters on the crystalliser body.<\/li>\n<li>Density or refractive index probe as a TDS cross-check.<\/li>\n<\/ul>\n<p>Redundancy here is deliberate; the process cost of a single sensor failure exceeds the cost of a redundant pair by more than 20 times.<\/p>\n<h2 id=\"stage-6-solids-handling\"><span class=\"ez-toc-section\" id=\"Stage_6_Solids_Handling\"><\/span>Stage 6: Solids Handling<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Solids handling instrumentation is less about water and more about moisture:<\/p>\n<ul>\n<li>Moisture probe on the centrifuge cake discharge.<\/li>\n<li>Temperature and pressure on the dryer.<\/li>\n<li>Suspended solids sensor on the centrifuge overflow line.<\/li>\n<\/ul>\n<p>Fines carryover from the centrifuge is a classic hidden loop that sends product back into the liquid line, so the suspended solids sensor here has surprising leverage.<\/p>\n<h2 id=\"stage-7-distillate-and-reuse\"><span class=\"ez-toc-section\" id=\"Stage_7_Distillate_and_Reuse\"><\/span>Stage 7: Distillate and Reuse<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The reuse loop is where all the plant&rsquo;s effort pays off. Sensors:<\/p>\n<ul>\n<li>Low-range contacting conductivity cell on the distillate line (2\u201320 \u03bcS\/cm).<\/li>\n<li><a href=\"\/tag\/Conductivity-Meter\" target=\"_blank\"><strong><a href=\"\/tag\/conductivity-meter\/\" target=\"_blank\"><strong>conductivity meter<\/strong><\/a><\/strong><\/a> on the reuse header before it enters consumers.<\/li>\n<li>Multi-parameter sensor on the cooling tower make-up loop, if that is the primary reuse consumer.<\/li>\n<li>Free-chlorine transmitter on the reuse header if biocide dosing is applied.<\/li>\n<\/ul>\n<p>This cluster confirms that reused water meets the specification of its downstream consumer.<\/p>\n<h2 id=\"stage-8-utilities-and-auxiliaries\"><span class=\"ez-toc-section\" id=\"Stage_8_Utilities_and_Auxiliaries\"><\/span>Stage 8: Utilities and Auxiliaries<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Utility sensors serve the ZLD plant itself: steam flow, chilled water flow, compressed air pressure, electrical energy metering. These are not water-quality sensors, but they enter the digital twin so that the mass and energy balance closes across the whole plant.<\/p>\n<h2 id=\"the-digital-twin-layer\"><span class=\"ez-toc-section\" id=\"The_Digital_Twin_Layer\"><\/span>The Digital Twin Layer<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Above the sensor cluster sits the digital twin. The twin ingests every historian tag at 1-minute resolution, closes a mass and energy balance every five minutes and drives operator-actionable alerts when recovery, energy or product quality drift. The twin does not do its job without a reliable sensor cluster underneath \u2014 instrument health becomes a first-order concern for the twin&rsquo;s owners.<\/p>\n<p>Signals that the twin needs from each sensor:<\/p>\n<ul>\n<li>Primary reading.<\/li>\n<li>Sensor status (healthy, calibration due, drift-flag).<\/li>\n<li>Cell condition (fouling indicator where available).<\/li>\n<li>Calibration age.<\/li>\n<li>Confidence-weighted reading (some transmitters output this natively).<\/li>\n<\/ul>\n<p>Shanghai ChiMay&rsquo;s transmitter platform exposes each of these into the historian, giving the twin a defensible input surface.<\/p>\n<h2 id=\"instrumentation-coverage-metric\"><span class=\"ez-toc-section\" id=\"Instrumentation_Coverage_Metric\"><\/span>Instrumentation Coverage Metric<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A single portfolio metric \u2014 instrumentation coverage on process-critical streams \u2014 has emerged as the leading indicator of ZLD plant availability. Portfolio owners with coverage above 90% report 92\u201396% availability. Those below 70% report 82\u201388% availability with a much wider distribution of outcomes. The metric is now tracked at board level in several major operators.<\/p>\n<h2 id=\"what-retrofit-teams-change-first\"><span class=\"ez-toc-section\" id=\"What_Retrofit_Teams_Change_First\"><\/span>What Retrofit Teams Change First<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Retrofit teams entering a legacy ZLD plant typically prioritise three interventions:<\/p>\n<ol>\n<li>Migrate contacting conductivity cells to toroidal above 50 mS\/cm.<\/li>\n<li>Move single-junction pH to double-junction on sulfide and high-solids streams.<\/li>\n<li>Add historian retention to 90 days at 1-minute resolution before any control-system changes.<\/li>\n<\/ol>\n<p>Each of these interventions is cheap relative to the availability gain it produces.<\/p>\n<h2 id=\"closing-note\"><span class=\"ez-toc-section\" id=\"Closing_Note\"><\/span>Closing Note<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The sensor cluster is the invisible layer that closes the water loop in a modern ZLD plant. It is not glamorous, and its cost is a small share of capital, but it decides whether the plant hits its recovery, mineral quality and reuse targets. Shanghai ChiMay&rsquo;s <a href=\"\/tag\/water-quality-analyzer\" target=\"_blank\"><strong>water quality analyzer<\/strong><\/a> and <a href=\"\/tag\/softener-valve\" target=\"_blank\"><strong>softener valve<\/strong><\/a> platforms are engineered around the reality that ZLD lives or dies on the coordinated performance of that cluster.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>title: &ldquo;Inside a Modern ZLD Plant: The Sensor Cluster That Closes the Water Loop with Shanghai ChiMay&rdquo; date: 2026-07-10 category: Zero Liquid Discharge &amp; Water Circularity audience: Operations Managers &amp; Instrument Engineers tags: [ZLD, sensor cluster, water loop, digital twin, Shanghai ChiMay] Inside a Modern ZLD Plant: The Sensor Cluster That Closes the Water Loop&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[1],"tags":[158,174,147,134481,11066,154],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"ru","enabled_languages":["en","es","fr","ru","ar"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/posts\/31228"}],"collection":[{"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/comments?post=31228"}],"version-history":[{"count":0,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/posts\/31228\/revisions"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/media?parent=31228"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/categories?post=31228"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/ru\/wp-json\/wp\/v2\/tags?post=31228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}