{"id":24520,"date":"2024-09-09T15:00:30","date_gmt":"2024-09-09T07:00:30","guid":{"rendered":"https:\/\/shchimay.com\/?p=24520"},"modified":"2024-09-11T12:46:54","modified_gmt":"2024-09-11T04:46:54","slug":"fiveeasy-plus-ph-meter-manual","status":"publish","type":"post","link":"https:\/\/shchimay.com\/tr\/fiveeasy-plus-ph-meter-manual\/","title":{"rendered":"fiveeasy plus ph \u00f6l\u00e7er k\u0131lavuzu"},"content":{"rendered":"<h1 id=\"proper-calibration-techniques-for-the-fiveeasy-plus-ph-meter-wpaicgheading\">FiveEasy Plus pH \u00d6l\u00e7\u00fcm Cihaz\u0131 i\u00e7in Uygun Kalibrasyon Teknikleri<\/h1>\n<p>\nDo\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sa\u011flamak i\u00e7in pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun \u015fekilde kalibre edilmesi \u00f6nemlidir. FiveEasy Plus pH \u00f6l\u00e7\u00fcm cihaz\u0131, kullan\u0131m kolayl\u0131\u011f\u0131 ve do\u011frulu\u011fu nedeniyle bir\u00e7ok laboratuvar i\u00e7in pop\u00fcler bir se\u00e7imdir. Bu makalede, en iyi sonu\u00e7lar\u0131 elde etmenize yard\u0131mc\u0131 olmak amac\u0131yla FiveEasy Plus pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun kalibrasyon tekniklerini tart\u0131\u015faca\u011f\u0131z.<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/Spec-pH-ORP8500A-meter-pH-controller-with-RS485.png\" alt=\"alt-340\" class=\"wp-image-340\" id=\"i340\" \/><\/p>\n<p>PH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131 kalibre etmeden \u00f6nce gerekli t\u00fcm malzemeleri toplaman\u0131z \u00f6nemlidir. Bilinen pH de\u011ferlerine (tipik olarak pH 4,01, pH 7,00 ve pH 10,01) sahip kalibrasyon tamponlar\u0131na ihtiyac\u0131n\u0131z olacakt\u0131r. Kalibrasyonunuzun do\u011frulu\u011funu etkileyebilece\u011fi i\u00e7in tamponlar\u0131n yeni oldu\u011fundan ve son kullanma tarihlerinin ge\u00e7medi\u011finden emin olun. Ayr\u0131ca tamponlar\u0131 tutmak i\u00e7in temiz bir beher veya kab\u0131n yan\u0131 s\u0131ra pH \u00f6l\u00e7er i\u00e7in temiz ve kuru bir elektroda ihtiyac\u0131n\u0131z olacak.<\/p>\n<p>Kalibrasyon i\u015flemine ba\u015flamak i\u00e7in pH \u00f6l\u00e7eri a\u00e7\u0131n ve en az 30 saat \u0131s\u0131nmas\u0131na izin verin. dakika. Bu, okumalar\u0131n istikrarl\u0131 ve do\u011fru olmas\u0131n\u0131 sa\u011flayacakt\u0131r. Cihaz haz\u0131r oldu\u011funda elektrodu pH 7,00 tampon \u00e7\u00f6zeltisine bat\u0131r\u0131n ve stabil hale gelmesini bekleyin. Sayac\u0131n 7,00&#8217;a yak\u0131n bir okuma g\u00f6stermesi gerekir. Okuma 0,01 pH biriminden fazla hatal\u0131ysa kalibrasyonu ayarlaman\u0131z gerekecektir.<\/p>\n<p><div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-24520-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/FCT-8350.mp4?_=1\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/FCT-8350.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/FCT-8350.mp4<\/a><\/video><\/div>Kalibrasyonu ayarlamak i\u00e7in, okumay\u0131 pH 7,00 tampon \u00e7\u00f6zeltisiyle e\u015fle\u015ftirmek amac\u0131yla pH metre \u00fczerindeki kalibrasyon d\u00fc\u011fmelerini kullan\u0131n. Okuma stabil ve do\u011fru oldu\u011funda, elektrodu deiyonize suyla durulay\u0131n ve i\u015flemi pH 4,01 ve pH 10,01 tampon \u00e7\u00f6zeltileriyle tekrarlay\u0131n. Kirlenmeyi \u00f6nlemek ve do\u011fru okumalar sa\u011flamak i\u00e7in her kalibrasyon aras\u0131nda elektrodu durulad\u0131\u011f\u0131n\u0131zdan emin olun.<\/p>\n<p>PH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 \u00fc\u00e7 tampon sol\u00fcsyonunun t\u00fcm\u00fc ile kalibre ettikten sonra, standart bir sol\u00fcsyon veya bir pH \u00f6l\u00e7\u00fcm cihaz\u0131 gibi bilinen bir pH sol\u00fcsyonunu \u00f6l\u00e7erek son bir kontrol ger\u00e7ekle\u015ftirebilirsiniz. bilinen bir pH de\u011ferine sahip numune. Kalibrasyonun do\u011fru oldu\u011fundan emin olmak i\u00e7in okuma, bilinen de\u011ferin 0,01 pH birimi dahilinde olmal\u0131d\u0131r.<\/p>\n<p>Do\u011frulu\u011fu ve g\u00fcvenilirli\u011fi korumak i\u00e7in pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131 d\u00fczenli olarak kalibre etmeniz \u00f6nemlidir. Kullan\u0131m s\u0131kl\u0131\u011f\u0131na ba\u011fl\u0131 olarak pH metrenin en az haftada bir kez veya her kullan\u0131mdan \u00f6nce kalibre edilmesi \u00f6nerilir. Bu, okumalarda herhangi bir sapman\u0131n \u00f6nlenmesine yard\u0131mc\u0131 olacak ve \u00f6l\u00e7\u00fcmlerinizin tutarl\u0131 olmas\u0131n\u0131 sa\u011flayacakt\u0131r.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Model No.<\/td>\n<td colspan=\"2\">CIT-8800 End\u00fcktif \u0130letkenlik \/ Konsantrasyon \u00c7evrimi\u00e7i Kontrol Cihaz\u0131<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\u00d6l\u00e7\u00fcm aral\u0131\u011f\u0131<\/td>\n<td>\u0130letkenlik<\/td>\n<td>0,00\\\u03bcS\/cm ~ 2000mS\/cm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Konsantrasyon<\/td>\n<td>1.NaOH\\\uff0c\\\uff080-15\\\uff09 y\u00fczde veya\\\uff0825-50\\\uff09 y\u00fczde \\\uff1b<\/td>\n<\/tr>\n<tr>\n<td>2.HNO3\\\uff08sens\u00f6r\u00fcn Korozyon direncine dikkat edin\\\uff09\\\uff080-25\\\uff09 y\u00fczde veya\\\uff0836-82\\\uff09 y\u00fczde \\\uff1b<\/td>\n<\/tr>\n<tr>\n<td>3.Kullan\u0131c\u0131 tan\u0131ml\u0131 konsantrasyon e\u011frileri.<\/td>\n<\/tr>\n<tr>\n<td>TDS<\/td>\n<td>0,00ppm~1000ppt<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td>\\\uff080.0 ~ 120.0\\\uff09\\\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\u00c7\u00f6z\u00fcn\u00fcrl\u00fck<\/td>\n<td>\u0130letkenlik<\/td>\n<td>0,01\\\u03bcS\/cm<\/td>\n<\/tr>\n<tr>\n<td>Konsantrasyon<\/td>\n<td>0.01%<\/td>\n<\/tr>\n<tr>\n<td>TDS<\/td>\n<td>0,01ppm<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td>0,1\\\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Do\u011fruluk<\/td>\n<td rowspan=\"3\">\u0130letkenlik<\/td>\n<td>0\\\u03bcS\/cm ~1000\\\u03bcS\/cm \\\u00b110\\\u03bcS\/cm<\/td>\n<\/tr>\n<tr>\n<td>1 mS\/cm~500 mS\/cm = y\u00fczde 11,0 <\/td>\n<\/tr>\n<tr>\n<td>500mS\/cm~2000 mS\/cm = y\u00fczde 11,0 <\/td>\n<\/tr>\n<tr>\n<td>TDS<\/td>\n<td>1,5 seviye<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td>\\\u00b10,5\\\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">S\u0131cakl\u0131k. tazminat<\/td>\n<td>\u00f6\u011fe<\/td>\n<td>Pt1000<\/td>\n<\/tr>\n<tr>\n<td>aral\u0131k<\/td>\n<td>\\\uff080.0~120.0\\\uff09\\\u2103 do\u011frusal telafi<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\\\uff084~20\\\uff09mA Ak\u0131m \u00e7\u0131k\u0131\u015f\u0131<\/td>\n<td>kanallar<\/td>\n<td>\u00c7ift kanallar<\/td>\n<\/tr>\n<tr>\n<td>\u00f6zellikler<\/td>\n<td>\u0130zole, ayarlanabilir, tersine \u00e7evrilebilir, 4-20MA \u00e7\u0131k\u0131\u015f, cihazlar\/verici modu.<\/td>\n<\/tr>\n<tr>\n<td>D\u00f6ng\u00fc direnci<\/td>\n<td>400\\\u03a9\\\uff08Maks\\\uff09\\\uff0cDC 24V<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u00f6z\u00fcn\u00fcrl\u00fck<\/td>\n<td>\\\u00b10,1mA<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Kontrol ki\u015fisi<\/td>\n<td>Kanallar<\/td>\n<td>\u00dc\u00e7l\u00fc kanallar<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim<\/td>\n<td>Fotoelektrik r\u00f6le \u00e7\u0131k\u0131\u015f\u0131<\/td>\n<\/tr>\n<tr>\n<td>Programlanabilir<\/td>\n<td>Programlanabilir \\\uff08 s\u0131cakl\u0131k \\\u3001iletkenlik\/konsantrasyon\/TDS\\\u3001zamanlama\\\uff09\u00e7\u0131k\u0131\u015f<\/td>\n<\/tr>\n<tr>\n<td>\u00d6zellikler<\/td>\n<td>S\u0131cakl\u0131k\\\u3001iletkenlik\/konsantrasyon\/TDS\\\u3001 zamanlamas\u0131 NO\/NC\/PID se\u00e7imi ayarlanabilir<\/td>\n<\/tr>\n<tr>\n<td>Diren\u00e7 y\u00fck\u00fc<\/td>\n<td>50mA\\\uff08Maks\\\uff09\\\uff0cAC\/DC 30V\\\uff08Maks\\\uff09<\/td>\n<\/tr>\n<tr>\n<td>Veri ileti\u015fimi<\/td>\n<td colspan=\"2\">RS485,MODBUS protokol\u00fc<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 kayna\u011f\u0131<\/td>\n<td colspan=\"2\">DC 24V\\\u00b14V<\/td>\n<\/tr>\n<tr>\n<td>T\u00fcketim<\/td>\n<td colspan=\"2\">5.5W<\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015fma ortam\u0131<\/td>\n<td colspan=\"2\">S\u0131cakl\u0131k\\\uff1a\\\uff080~50\\\uff09\\\u2103 Ba\u011f\u0131l Nem\\\uff1a\\\u226485 y\u00fczde RH(yo\u011fu\u015fmas\u0131z)<\/td>\n<\/tr>\n<tr>\n<td>Depolama<\/td>\n<td colspan=\"2\">S\u0131cakl\u0131k\\\uff1a(-20~60)\\\u2103 Ba\u011f\u0131l Nem\\\uff1a\\\u226485 y\u00fczde RH(yo\u011fu\u015fmas\u0131z)<\/td>\n<\/tr>\n<tr>\n<td>Koruma d\u00fczeyi<\/td>\n<td colspan=\"2\">IP65\\\uff08arka kapakl\u0131\\\uff09<\/td>\n<\/tr>\n<tr>\n<td>Anahat boyutu<\/td>\n<td colspan=\"2\">96mm\\\u00d796 mm\\\u00d794mm (Y\\\u00d7G\\\u00d7D)<\/td>\n<\/tr>\n<tr>\n<td>Delik boyutu<\/td>\n<td colspan=\"2\">91mm\\\u00d791mm(Y\\\u00d7G)<\/td>\n<\/tr>\n<tr>\n<td>Kurulum<\/td>\n<td colspan=\"2\">Panele monteli, h\u0131zl\u0131 kurulum<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nD\u00fczenli kalibrasyonun yan\u0131 s\u0131ra pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun \u015fekilde saklanmas\u0131 ve bak\u0131m\u0131 da \u00f6nemlidir. PH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 temiz ve kuru bir ortamda, do\u011frudan g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131ndan ve a\u015f\u0131r\u0131 s\u0131cakl\u0131klardan uzakta saklay\u0131n. Elektrodu d\u00fczenli olarak yumu\u015fak bir deterjanla temizleyin ve okumalar\u0131 etkileyebilecek kirleticileri gidermek i\u00e7in deiyonize suyla durulay\u0131n.<\/p>\n<p>Sonu\u00e7 olarak, do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sa\u011flamak i\u00e7in FiveEasy Plus pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun \u015fekilde kalibre edilmesi \u00e7ok \u00f6nemlidir. Bu makalede \u00f6zetlenen ad\u0131mlar\u0131 takip ederek ve pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131 d\u00fczenli olarak kalibre ederek en iyi sonu\u00e7lar\u0131 elde edebilir ve \u00e7al\u0131\u015fman\u0131z\u0131n kalitesini koruyabilirsiniz. Yeni kalibrasyon tamponlar\u0131 kullanmay\u0131, kalibrasyonlar aras\u0131nda elektrodu durulamay\u0131 ve \u00f6mr\u00fcn\u00fc ve do\u011frulu\u011funu uzatmak i\u00e7in pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 uygun \u015fekilde saklamay\u0131 unutmay\u0131n.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>FiveEasy Plus pH \u00d6l\u00e7\u00fcm Cihaz\u0131 i\u00e7in Uygun Kalibrasyon Teknikleri Do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sa\u011flamak i\u00e7in pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun \u015fekilde kalibre edilmesi \u00f6nemlidir. FiveEasy Plus pH \u00f6l\u00e7\u00fcm cihaz\u0131, kullan\u0131m kolayl\u0131\u011f\u0131 ve do\u011frulu\u011fu nedeniyle bir\u00e7ok laboratuvar i\u00e7in pop\u00fcler bir se\u00e7imdir. Bu makalede, en iyi sonu\u00e7lar\u0131 elde etmenize yard\u0131mc\u0131 olmak amac\u0131yla FiveEasy Plus pH \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1680,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"default","_kad_post_title":"default","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[200],"tags":[134407,134429,11579,134481],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"tr","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/24520"}],"collection":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/comments?post=24520"}],"version-history":[{"count":17,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/24520\/revisions"}],"predecessor-version":[{"id":25101,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/24520\/revisions\/25101"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/media\/1680"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/media?parent=24520"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/categories?post=24520"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/tags?post=24520"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}