{"id":24534,"date":"2024-09-09T15:10:30","date_gmt":"2024-09-09T07:10:30","guid":{"rendered":"https:\/\/shchimay.com\/?p=24534"},"modified":"2024-09-11T12:10:05","modified_gmt":"2024-09-11T04:10:05","slug":"conductivity-meter-ct-650-manual","status":"publish","type":"post","link":"https:\/\/shchimay.com\/tr\/conductivity-meter-ct-650-manual\/","title":{"rendered":"iletkenlik \u00f6l\u00e7er ct-650 k\u0131lavuzu"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/tr\/conductivity-meter-ct-650-manual\/#CT-650_Iletkenlik_Olcer_icin_Uygun_Kalibrasyon_Teknikleri\" title=\"CT-650 \u0130letkenlik \u00d6l\u00e7er i\u00e7in Uygun Kalibrasyon Teknikleri\">CT-650 \u0130letkenlik \u00d6l\u00e7er i\u00e7in Uygun Kalibrasyon Teknikleri<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/tr\/conductivity-meter-ct-650-manual\/#CT-650_Iletkenlik_Olcerle_Ilgili_Genel_Sorunlari_Giderme\" title=\"CT-650 \u0130letkenlik \u00d6l\u00e7erle \u0130lgili Genel Sorunlar\u0131 Giderme\">CT-650 \u0130letkenlik \u00d6l\u00e7erle \u0130lgili Genel Sorunlar\u0131 Giderme<\/a><\/li><\/ul><\/nav><\/div>\n<h1 id=\"proper-calibration-techniques-for-the-ct-650-conductivity-meter-wpaicgheading\"><span class=\"ez-toc-section\" id=\"CT-650_Iletkenlik_Olcer_icin_Uygun_Kalibrasyon_Teknikleri\"><\/span>CT-650 \u0130letkenlik \u00d6l\u00e7er i\u00e7in Uygun Kalibrasyon Teknikleri<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nDo\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sa\u011flamak i\u00e7in iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun \u015fekilde kalibre edilmesi \u00f6nemlidir. CT-650 iletkenlik \u00f6l\u00e7er, y\u00fcksek do\u011fruluk ve hassasiyet d\u00fczeyi nedeniyle bir\u00e7ok laboratuvar ve end\u00fcstriyel ortam i\u00e7in pop\u00fcler bir se\u00e7imdir. CT-650&#8217;nin performans\u0131n\u0131 korumak i\u00e7in k\u0131lavuzda belirtilen uygun kalibrasyon tekniklerini takip etmek \u00f6nemlidir.<\/p>\n<p>CT-650 iletkenlik \u00f6l\u00e7eri kalibre etmenin ilk ad\u0131m\u0131 cihaz\u0131n temiz ve kirden ar\u0131nm\u0131\u015f oldu\u011fundan emin olmakt\u0131r. herhangi bir kal\u0131nt\u0131 veya kal\u0131nt\u0131. Bu, elektrotlar\u0131 temiz, nemli bir bezle hafif\u00e7e silerek ve kalibrasyon i\u015flemine devam etmeden \u00f6nce tamamen kurumas\u0131n\u0131 sa\u011flayarak yap\u0131labilir. Ayr\u0131ca elektrotlar\u0131n durumunu kontrol etmek ve a\u015f\u0131nma veya hasar belirtileri g\u00f6steriyorsa de\u011fi\u015ftirmek de \u00f6nemlidir.<\/p>\n<p>Elektrotlar temiz ve iyi durumda oldu\u011funda bir sonraki ad\u0131m kalibrasyon \u00e7\u00f6zeltilerini haz\u0131rlamakt\u0131r. CT-650 iletkenlik \u00f6l\u00e7er tipik olarak iki kalibrasyon \u00e7\u00f6z\u00fcm\u00fc gerektirir: d\u00fc\u015f\u00fck iletkenli\u011fe sahip \u00e7\u00f6z\u00fcm ve y\u00fcksek iletkenli\u011fe sahip \u00e7\u00f6z\u00fcm. Bu sol\u00fcsyonlar k\u0131lavuzda verilen talimatlara g\u00f6re haz\u0131rlanmal\u0131 ve kontaminasyonu \u00f6nlemek i\u00e7in temiz, kuru kaplarda saklanmal\u0131d\u0131r.<\/p>\n<div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-24534-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROS-2210-RO\u7a0b\u5e8f\u63a7\u5236\u53cc\u8def\u7535%20u5bfc\u7387.mp4?_=1\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROS-2210-RO\u7a0b\u5e8f\u63a7\u5236\u53cc\u8def\u7535%20u5bfc\u7387.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROS-2210-RO\u7a0b\u5e8f\u63a7\u5236\u53cc\u8def\u7535%20u5bfc\u7387.mp4<\/a><\/video><\/div>\n<p>CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 kalibre etmeden \u00f6nce cihaz\u0131n d\u00fczg\u00fcn \u015fekilde kuruldu\u011fundan ve kullan\u0131ma haz\u0131r oldu\u011fundan emin olmak \u00f6nemlidir. Bu, \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n a\u00e7\u0131k oldu\u011fundan, elektrotlar\u0131n g\u00fcvenli bir \u015fekilde tak\u0131ld\u0131\u011f\u0131ndan ve gerekirse s\u0131cakl\u0131k dengeleme \u00f6zelli\u011finin etkinle\u015ftirildi\u011finden emin olmay\u0131 i\u00e7erir. Kalibrasyon i\u015flemine ba\u015flamadan \u00f6nce cihaz\u0131n birka\u00e7 dakika \u0131s\u0131nmas\u0131na izin vermek de \u00f6nemlidir.<\/p>\n<p>CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 kalibre etmek i\u00e7in, elektrotlar\u0131 d\u00fc\u015f\u00fck iletkenlik kalibrasyon \u00e7\u00f6zeltisine bat\u0131rarak ve \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n stabilize olmas\u0131n\u0131 sa\u011flayarak ba\u015flay\u0131n. . Cihazdaki okuma sabitlendikten sonra, ekran kalibrasyon sol\u00fcsyonunun bilinen iletkenlik de\u011feriyle e\u015fle\u015fene kadar kalibrasyon d\u00fc\u011fmesini veya cihazdaki ayarlar\u0131 ayarlay\u0131n. Kalibrasyon ayarlar\u0131n\u0131 uygun \u015fekilde ayarlad\u0131\u011f\u0131n\u0131zdan emin olarak bu i\u015flemi y\u00fcksek iletkenlik kalibrasyon \u00e7\u00f6zeltisiyle tekrarlay\u0131n.<\/p>\n<p>CT-650 iletkenlik \u00f6l\u00e7eri kalibre ettikten sonra, kalan kalibrasyon \u00e7\u00f6zeltisini gidermek i\u00e7in elektrotlar\u0131 temiz suyla durulamak \u00f6nemlidir. Ayr\u0131ca, sayac\u0131n do\u011fru bir \u015fekilde okundu\u011fundan emin olmak i\u00e7in, bilinen bir standart \u00e7\u00f6zeltinin iletkenli\u011fini \u00f6l\u00e7erek cihaz\u0131n performans\u0131n\u0131 h\u0131zl\u0131 bir \u015fekilde kontrol etmek de iyi bir fikirdir.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>pH\/ORP-8500A pH\/ORP \u00c7evrimi\u00e7i \u00d6l\u00e7er<\/td>\n<\/tr>\n<tr>\n<td>Aral\u0131k<\/td>\n<td>pH:0.00~14.00; ORP:(-1999~+1999)mV; S\u0131cakl\u0131k:(0,0~100,0)\\\u00b0C (S\u0131cakl\u0131k Telafisi: NTC10K)<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u00f6z\u00fcn\u00fcrl\u00fck<\/td>\n<td>pH:0,01; ORP: 1mV; S\u0131cakl\u0131k:0,1\\\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Do\u011fruluk<\/td>\n<td>pH:+\/-0,1; ORP: +\/-5mV(elektronik \u00fcnite); S\u0131cakl\u0131k: +\/-0,5\\\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k. tazminat<\/td>\n<td>NTC10K S\u0131cakl\u0131k telafisi<\/td>\n<\/tr>\n<tr>\n<td>Orta S\u0131cakl\u0131k<\/td>\n<td>(0~80)\\\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Analog \u00e7\u0131k\u0131\u015f<\/td>\n<td>\u00c7ift kanal izole edilmi\u015ftir; ta\u015f\u0131nabilir(4~20)mA, cihazlar\/verici modu<\/td>\n<\/tr>\n<tr>\n<td>Kontrol \u00c7\u0131k\u0131\u015f\u0131<\/td>\n<td>\u00dc\u00e7 kanall\u0131 yar\u0131 iletken fotoelektrik anahtar, y\u00fck ak\u0131m\u0131: AC\/DC 30V, 50mA(maks.)<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim ba\u011flant\u0131 noktas\u0131<\/td>\n<td>RS485,Modbus RTU protokol\u00fc<\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015fma Ortam\u0131<\/td>\n<td>S\u0131cakl\u0131k(0~80)\\\u2103; ba\u011f\u0131l nem <95%RH (non-condensing)<\/td>\n<\/tr>\n<tr>\n<td>Depolama Ortam\u0131<\/td>\n<td>S\u0131cakl\u0131k.(-20~60)\\\u2103;Ba\u011f\u0131l Nem \\\u226485 y\u00fczde RH (yo\u011fu\u015fmas\u0131z)<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 Kayna\u011f\u0131<\/td>\n<td>DC 24V<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 t\u00fcketimi<\/td>\n<td><3W<\/td>\n<\/tr>\n<tr>\n<td>Koruma d\u00fczeyi<\/td>\n<td>IP65 (arka kapakl\u0131)<\/td>\n<\/tr>\n<tr>\n<td>Boyut<\/td>\n<td>96mmx96mmx94mm(YxGxD)<\/td>\n<\/tr>\n<tr>\n<td>Delik Boyutu<\/td>\n<td>91mmx91mm(YxG)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nD\u00fczenli kalibrasyona ek olarak, optimum performans\u0131n sa\u011flanmas\u0131 i\u00e7in CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun bak\u0131m prosed\u00fcrlerini takip etmek \u00f6nemlidir. Bu, elektrotlar\u0131n d\u00fczenli olarak temizlenmesini, cihaz\u0131n temiz ve kuru bir ortamda saklanmas\u0131n\u0131 ve gerekti\u011finde a\u015f\u0131nm\u0131\u015f veya hasar g\u00f6rm\u00fc\u015f par\u00e7alar\u0131n de\u011fi\u015ftirilmesini i\u00e7erir.<\/p>\n<p>Sonu\u00e7 olarak, do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sa\u011flamak i\u00e7in CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun \u015fekilde kalibre edilmesi \u015fartt\u0131r. Kullan\u0131c\u0131lar, k\u0131lavuzda belirtilen kalibrasyon tekniklerini takip ederek ve cihaz\u0131n bak\u0131m\u0131n\u0131 uygun \u015fekilde yaparak, CT-650&#8217;nin gelecek y\u0131llarda da do\u011fru ve hassas iletkenlik \u00f6l\u00e7\u00fcmleri sa\u011flamaya devam etmesini sa\u011flayabilirler.<\/p>\n<h1 id=\"troubleshooting-common-issues-with-the-ct-650-conductivity-meter-wpaicgheading\"><span class=\"ez-toc-section\" id=\"CT-650_Iletkenlik_Olcerle_Ilgili_Genel_Sorunlari_Giderme\"><\/span>CT-650 \u0130letkenlik \u00d6l\u00e7erle \u0130lgili Genel Sorunlar\u0131 Giderme<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\n\u0130letkenlik \u00f6l\u00e7er, bir \u00e7\u00f6zeltinin elektriksel iletkenli\u011fini \u00f6l\u00e7mek i\u00e7in gerekli bir ara\u00e7t\u0131r ve mevcut iyonlar\u0131n konsantrasyonu hakk\u0131nda de\u011ferli bilgiler sa\u011flayabilir. CT-650 iletkenlik \u00f6l\u00e7er, do\u011frulu\u011fu ve g\u00fcvenilirli\u011fi nedeniyle ara\u015ft\u0131rmac\u0131lar ve profesyoneller aras\u0131nda pop\u00fcler bir se\u00e7imdir. Ancak herhangi bir elektronik cihaz gibi CT-650 iletkenlik \u00f6l\u00e7er de performans\u0131n\u0131 etkileyebilecek sorunlarla kar\u015f\u0131la\u015fabilir. Bu makalede, kullan\u0131c\u0131lar\u0131n CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131nda kar\u015f\u0131la\u015fabilece\u011fi baz\u0131 genel sorunlar\u0131 tart\u0131\u015faca\u011f\u0131z ve bunlar\u0131 \u00e7\u00f6zmeye yard\u0131mc\u0131 olacak sorun giderme ipu\u00e7lar\u0131 sunaca\u011f\u0131z.<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/PH-1800-Ph-Controller.jpg\" alt=\"alt-6515\" class=\"wp-image-6515\" id=\"i6515\" \/><\/p>\n<p>\nKullan\u0131c\u0131lar\u0131n CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131nda kar\u015f\u0131la\u015fabilece\u011fi yayg\u0131n sorunlardan biri yanl\u0131\u015f okumalard\u0131r. Bunun nedeni kirli veya hasarl\u0131 elektrot, hatal\u0131 kalibrasyon veya di\u011fer elektronik cihazlardan kaynaklanan parazit gibi \u00e7e\u015fitli fakt\u00f6rler olabilir. Bu sorunu gidermek i\u00e7in kullan\u0131c\u0131lar\u0131n \u00f6ncelikle elektrodun temiz ve iyi durumda oldu\u011fundan emin olmalar\u0131 gerekir. Elektrot kirliyse yumu\u015fak bir deterjanla temizlenmeli ve dam\u0131t\u0131lm\u0131\u015f suyla iyice durulanmal\u0131d\u0131r.<\/p>\n<p>Daha sonra kullan\u0131c\u0131lar iletkenlik \u00f6l\u00e7erin kalibrasyonunu kontrol etmelidir. Saya\u00e7 uygun \u015fekilde kalibre edilmemi\u015fse hatal\u0131 okumalar verebilir. CT-650 iletkenlik \u00f6l\u00e7eri kalibre etmek i\u00e7in kullan\u0131c\u0131lar kullan\u0131m k\u0131lavuzunda verilen talimatlar\u0131 izlemelidir. Kalibrasyondan sonra \u00f6l\u00e7\u00fcm cihaz\u0131 hala hatal\u0131 okumalar sa\u011fl\u0131yorsa, kullan\u0131c\u0131lar parazite neden olabilecek herhangi bir elektronik cihaz\u0131 kontrol etmeli ve gerekirse \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 farkl\u0131 bir konuma ta\u015f\u0131mal\u0131d\u0131r.<\/p>\n<p>Kullan\u0131c\u0131lar\u0131n CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131nda kar\u015f\u0131la\u015fabilece\u011fi di\u011fer bir yayg\u0131n sorun yava\u015f bir tepki s\u00fcresidir. Bunun nedeni d\u00fc\u015f\u00fck pil, hasarl\u0131 elektrot veya ar\u0131zal\u0131 devre gibi \u00e7e\u015fitli fakt\u00f6rler olabilir. Bu sorunu gidermek i\u00e7in kullan\u0131c\u0131lar\u0131n \u00f6ncelikle iletkenlik \u00f6l\u00e7erin pil seviyesini kontrol etmesi gerekir. Pil zay\u0131fsa yenisiyle de\u011fi\u015ftirilmelidir.<\/p>\n<p>Kullan\u0131c\u0131lar ayr\u0131ca elektrotta herhangi bir hasar veya a\u015f\u0131nma ve y\u0131pranma olup olmad\u0131\u011f\u0131n\u0131 da kontrol etmelidir. Elektrot hasar g\u00f6rm\u00fc\u015fse yenisiyle de\u011fi\u015ftirilmelidir. Elektrot iyi durumdaysa kullan\u0131c\u0131lar iletkenlik \u00f6l\u00e7erin devresinde herhangi bir ar\u0131za olup olmad\u0131\u011f\u0131n\u0131 kontrol etmelidir. Devre ar\u0131zal\u0131ysa kullan\u0131c\u0131lar daha fazla yard\u0131m i\u00e7in \u00fcreticiyle ileti\u015fime ge\u00e7melidir.<\/p>\n<p>Kullan\u0131c\u0131lar\u0131n CT-650 iletkenlik \u00f6l\u00e7erle kar\u015f\u0131la\u015fabilece\u011fi son ortak sorun, okumalardaki sapmalard\u0131r. Bunun nedeni s\u0131cakl\u0131k dalgalanmalar\u0131, yanl\u0131\u015f kalibrasyon veya kirli elektrot gibi \u00e7e\u015fitli fakt\u00f6rler olabilir. Bu sorunu gidermek i\u00e7in kullan\u0131c\u0131lar\u0131n \u00f6ncelikle elektrodun temiz ve iyi durumda oldu\u011fundan emin olmalar\u0131 gerekir. Elektrot kirliyse daha \u00f6nce belirtildi\u011fi gibi temizlenmelidir.<\/p>\n<p>Kullan\u0131c\u0131lar ayr\u0131ca iletkenlik \u00f6l\u00e7erin kalibrasyonunu da kontrol etmelidir. Saya\u00e7 uygun \u015fekilde kalibre edilmemi\u015fse okumalarda sapmalar meydana gelebilir. CT-650 iletkenlik \u00f6l\u00e7eri yeniden kalibre etmek i\u00e7in kullan\u0131c\u0131lar kullan\u0131m k\u0131lavuzunda verilen talimatlar\u0131 izlemelidir. Kalibrasyondan sonra \u00f6l\u00e7\u00fcm cihaz\u0131 okumalarda hala sapma g\u00f6steriyorsa kullan\u0131c\u0131lar ortamdaki herhangi bir s\u0131cakl\u0131k dalgalanmas\u0131n\u0131 kontrol etmeli ve gerekli ayarlamalar\u0131 yapmal\u0131d\u0131r.<\/p>\n<p>Sonu\u00e7 olarak, CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131 bir \u00e7\u00f6z\u00fcm\u00fcn elektriksel iletkenli\u011fini \u00f6l\u00e7mek i\u00e7in g\u00fcvenilir bir ara\u00e7t\u0131r. . Ancak kullan\u0131c\u0131lar hatal\u0131 okumalar, yava\u015f tepki s\u00fcresi ve okumalarda sapma gibi sorunlarla kar\u015f\u0131la\u015fabilirler. Kullan\u0131c\u0131lar bu makalede verilen sorun giderme ipu\u00e7lar\u0131n\u0131 takip ederek bu yayg\u0131n sorunlar\u0131 \u00e7\u00f6zebilir ve CT-650 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n optimum performans\u0131n\u0131 sa\u011flayabilir.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>CT-650 \u0130letkenlik \u00d6l\u00e7er i\u00e7in Uygun Kalibrasyon Teknikleri Do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sa\u011flamak i\u00e7in iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n uygun \u015fekilde kalibre edilmesi \u00f6nemlidir. CT-650 iletkenlik \u00f6l\u00e7er, y\u00fcksek do\u011fruluk ve hassasiyet d\u00fczeyi nedeniyle bir\u00e7ok laboratuvar ve end\u00fcstriyel ortam i\u00e7in pop\u00fcler bir se\u00e7imdir. CT-650&#8217;nin performans\u0131n\u0131 korumak i\u00e7in k\u0131lavuzda belirtilen uygun kalibrasyon tekniklerini takip etmek \u00f6nemlidir. CT-650 iletkenlik \u00f6l\u00e7eri kalibre&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1223,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"default","_kad_post_title":"default","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[200],"tags":[158,134452,134481],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"tr","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/24534"}],"collection":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/comments?post=24534"}],"version-history":[{"count":17,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/24534\/revisions"}],"predecessor-version":[{"id":25070,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/24534\/revisions\/25070"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/media\/1223"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/media?parent=24534"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/categories?post=24534"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/tags?post=24534"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}