{"id":25219,"date":"2024-09-11T14:50:40","date_gmt":"2024-09-11T06:50:40","guid":{"rendered":"https:\/\/shchimay.com\/?p=25219"},"modified":"2024-09-13T16:46:18","modified_gmt":"2024-09-13T08:46:18","slug":"calibration-of-conductivity-meter-as-per-usp","status":"publish","type":"post","link":"https:\/\/shchimay.com\/tr\/calibration-of-conductivity-meter-as-per-usp\/","title":{"rendered":"usp&#039;ye g\u00f6re iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kalibrasyonu"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/shchimay.com\/tr\/calibration-of-conductivity-meter-as-per-usp\/#Ilac_Endustrisinde_Iletkenlik_Olcerlerde_Duzenli_Kalibrasyonun_Onemi\" title=\"\u0130la\u00e7 End\u00fcstrisinde \u0130letkenlik \u00d6l\u00e7erlerde D\u00fczenli Kalibrasyonun \u00d6nemi\">\u0130la\u00e7 End\u00fcstrisinde \u0130letkenlik \u00d6l\u00e7erlerde D\u00fczenli Kalibrasyonun \u00d6nemi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/shchimay.com\/tr\/calibration-of-conductivity-meter-as-per-usp\/#Iletkenlik_Olcerlerin_USP_Standartlarina_Gore_Kalibre_Edilmesine_Iliskin_Adim_Adim_Kilavuz\" title=\"\u0130letkenlik \u00d6l\u00e7erlerin USP Standartlar\u0131na G\u00f6re Kalibre Edilmesine \u0130li\u015fkin Ad\u0131m Ad\u0131m K\u0131lavuz\">\u0130letkenlik \u00d6l\u00e7erlerin USP Standartlar\u0131na G\u00f6re Kalibre Edilmesine \u0130li\u015fkin Ad\u0131m Ad\u0131m K\u0131lavuz<\/a><\/li><\/ul><\/nav><\/div>\n<h1 id=\"importance-of-regular-calibration-for-conductivity-meters-in-pharmaceutical-industry-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Ilac_Endustrisinde_Iletkenlik_Olcerlerde_Duzenli_Kalibrasyonun_Onemi\"><\/span>\u0130la\u00e7 End\u00fcstrisinde \u0130letkenlik \u00d6l\u00e7erlerde D\u00fczenli Kalibrasyonun \u00d6nemi<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\n\u0130la\u00e7 end\u00fcstrisinde, \u00e7\u00f6zeltilerin iletkenli\u011finin \u00f6l\u00e7\u00fclmesi s\u00f6z konusu oldu\u011funda do\u011fruluk ve kesinlik son derece \u00f6nemlidir. \u0130letkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131, test edilen \u00e7\u00f6z\u00fcmlerin gerekli standartlar\u0131 kar\u015f\u0131lad\u0131\u011f\u0131ndan emin olmak i\u00e7in farmas\u00f6tik laboratuvarlarda yayg\u0131n olarak kullan\u0131lmaktad\u0131r. Bu \u00f6l\u00e7\u00fcmlerin do\u011frulu\u011funu korumak i\u00e7in iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n d\u00fczenli kalibrasyonu \u015fartt\u0131r.<\/p>\n<p>Kalibrasyon, do\u011frulu\u011funu sa\u011flamak i\u00e7in bir \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n okumalar\u0131n\u0131 bilinen bir standartla kar\u015f\u0131la\u015ft\u0131rma i\u015flemidir. \u0130letkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131nda kalibrasyon, cihaz\u0131n standart \u00e7\u00f6zeltilerin iletkenlik de\u011ferlerine uyacak \u015fekilde ayarlanmas\u0131n\u0131 i\u00e7erir. Bu, \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sunmas\u0131n\u0131 sa\u011flar.<\/p>\n<p>Amerika Birle\u015fik Devletleri Farmakopesi (USP), farmas\u00f6tik laboratuvarlardaki iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n kalibrasyonu i\u00e7in y\u00f6nergeler belirler. USP kurallar\u0131na g\u00f6re iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n do\u011frulu\u011funu sa\u011flamak i\u00e7in d\u00fczenli aral\u0131klarla kalibre edilmesi gerekir. Kalibrasyon s\u0131kl\u0131\u011f\u0131 \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kullan\u0131m\u0131na ve yap\u0131lan \u00f6l\u00e7\u00fcmlerin kritikli\u011fine ba\u011fl\u0131d\u0131r.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"ph controller calibration\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/Q6cj5yVPF0A?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>\u0130letkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n d\u00fczenli kalibrasyonu \u00e7e\u015fitli nedenlerden dolay\u0131 \u00f6nemlidir. \u00d6ncelikle yap\u0131lan \u00f6l\u00e7\u00fcmlerin do\u011frulu\u011funu sa\u011flar. Yanl\u0131\u015f \u00f6l\u00e7\u00fcmler, test edilen \u00e7\u00f6z\u00fcmlerin kalitesi hakk\u0131nda yanl\u0131\u015f sonu\u00e7lara var\u0131lmas\u0131na yol a\u00e7abilir ve bu durum ila\u00e7 end\u00fcstrisi i\u00e7in ciddi sonu\u00e7lar do\u011furabilir. \u0130la\u00e7 laboratuvarlar\u0131, iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131 d\u00fczenli olarak kalibre ederek \u00f6l\u00e7\u00fcmlerinin g\u00fcvenilir ve tutarl\u0131 olmas\u0131n\u0131 sa\u011flayabilir.<\/p>\n<p>\u0130kinci olarak, d\u00fczenli kalibrasyon, iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n performans\u0131ndaki herhangi bir sapma veya de\u011fi\u015fikli\u011fin belirlenmesine yard\u0131mc\u0131 olur. Zamanla s\u0131cakl\u0131k, nem ve a\u015f\u0131nma ve y\u0131pranma gibi fakt\u00f6rler \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n do\u011frulu\u011funu etkileyebilir. Sayac\u0131 d\u00fczenli olarak kalibre ederek bu de\u011fi\u015fiklikler, \u00f6l\u00e7\u00fcmlerin kalitesini etkilemeden \u00f6nce tespit edilebilir ve d\u00fczeltilebilir.<\/p>\n<p>\u00dc\u00e7\u00fcnc\u00fc olarak, iletkenlik \u00f6l\u00e7erlerin d\u00fczenli kalibrasyonu, d\u00fczenleyici standartlara uyum i\u00e7in bir gerekliliktir. Farmas\u00f6tik laboratuvarlar\u0131n, \u00fcr\u00fcnlerinin kalitesini ve g\u00fcvenli\u011fini sa\u011flamak i\u00e7in USP gibi d\u00fczenleyici kurumlar taraf\u0131ndan belirlenen kat\u0131 kurallara uymalar\u0131 gerekmektedir. \u0130letkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n d\u00fczenli kalibrasyonu, bu standartlar\u0131 kar\u015f\u0131laman\u0131n ve yap\u0131lan \u00f6l\u00e7\u00fcmlerin g\u00fcvenilirli\u011fini g\u00f6stermenin \u00f6nemli bir par\u00e7as\u0131d\u0131r.<\/p>\n<p>Bir iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 USP y\u00f6nergelerine g\u00f6re kalibre etmek i\u00e7in, bilinen iletkenlik de\u011ferlerine sahip bir dizi standart \u00e7\u00f6z\u00fcm kullan\u0131l\u0131r. Cihaz, bu standart \u00e7\u00f6z\u00fcmlerin iletkenlik de\u011ferlerine uyacak \u015fekilde ayarlanarak do\u011fru \u00f6l\u00e7\u00fcmler sa\u011flamas\u0131 sa\u011flan\u0131r. Tutarl\u0131l\u0131k ve g\u00fcvenilirli\u011fi sa\u011flamak i\u00e7in kalibrasyon i\u015flemi e\u011fitimli personel taraf\u0131ndan standart bir prosed\u00fcr izlenerek ger\u00e7ekle\u015ftirilmelidir.<\/p>\n<p>Sonu\u00e7 olarak, ila\u00e7 end\u00fcstrisinde \u00f6l\u00e7\u00fcmlerin do\u011frulu\u011funu, g\u00fcvenilirli\u011fini ve uyumlulu\u011funu sa\u011flamak i\u00e7in iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n d\u00fczenli kalibrasyonu \u015fartt\u0131r. Farmas\u00f6tik laboratuvarlar, USP y\u00f6nergelerini takip ederek ve iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131 d\u00fczenli aral\u0131klarla kalibre ederek, \u00fcr\u00fcnlerinin kalitesini ve g\u00fcvenli\u011fini koruyabilir. Kalibrasyon, farmas\u00f6tik laboratuvarlarda kalite kontrol s\u00fcrecinin kritik bir par\u00e7as\u0131d\u0131r ve g\u00f6z ard\u0131 edilmemelidir.<\/p>\n<h1 id=\"step-by-step-guide-to-calibrating-conductivity-meters-according-to-usp-standards-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Iletkenlik_Olcerlerin_USP_Standartlarina_Gore_Kalibre_Edilmesine_Iliskin_Adim_Adim_Kilavuz\"><\/span>\u0130letkenlik \u00d6l\u00e7erlerin USP Standartlar\u0131na G\u00f6re Kalibre Edilmesine \u0130li\u015fkin Ad\u0131m Ad\u0131m K\u0131lavuz<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nBir iletkenlik \u00f6l\u00e7erin kalibre edilmesi, \u00e7e\u015fitli \u00e7\u00f6z\u00fcmlerde iletkenli\u011fin do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmlerini sa\u011flamada \u00f6nemli bir ad\u0131md\u0131r. Amerika Birle\u015fik Devletleri Farmakopesi (USP), ila\u00e7 ve di\u011fer end\u00fcstrilerdeki \u00f6l\u00e7\u00fcmlerin do\u011frulu\u011funu ve tutarl\u0131l\u0131\u011f\u0131n\u0131 sa\u011flamak amac\u0131yla iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n kalibrasyonu i\u00e7in standartlar belirlemi\u015ftir. Bu yaz\u0131da, bir iletkenlik \u00f6l\u00e7erin USP standartlar\u0131na g\u00f6re nas\u0131l kalibre edilece\u011fine dair ad\u0131m ad\u0131m bir k\u0131lavuz sunaca\u011f\u0131z.<\/p>\n<p>\u0130letkenlik \u00f6l\u00e7eri kalibre etmenin ilk ad\u0131m\u0131, gerekli t\u00fcm ekipman\u0131 toplamakt\u0131r. Buna iletkenlik \u00f6l\u00e7er, kalibrasyon standartlar\u0131 (tipik olarak 1,41 mS\/cm ve 12,88 mS\/cm), dam\u0131t\u0131lm\u0131\u015f su, temiz bir beher ve bir kar\u0131\u015ft\u0131r\u0131c\u0131 dahildir. Kalibrasyon standartlar\u0131n\u0131n yeni oldu\u011fundan ve ge\u00e7erlilik s\u00fcrelerinin dolmad\u0131\u011f\u0131ndan emin olmak \u00f6nemlidir \u00e7\u00fcnk\u00fc bu, kalibrasyonun do\u011frulu\u011funu etkileyebilir.<\/p>\n<p>T\u00fcm ekipman\u0131 toplad\u0131ktan sonraki ad\u0131m, kalibrasyon standartlar\u0131n\u0131 haz\u0131rlamakt\u0131r. Herhangi bir yabanc\u0131 maddeyi \u00e7\u0131karmak i\u00e7in beheri dam\u0131t\u0131lm\u0131\u015f suyla durulayarak ba\u015flay\u0131n. Daha sonra behere az miktarda 1,41 mS\/cm kalibrasyon standard\u0131n\u0131 d\u00f6k\u00fcn ve iletkenlik \u00f6l\u00e7erin \u00fczerine yerle\u015ftirin. Sens\u00f6r\u00fcn tamamen sol\u00fcsyona dald\u0131r\u0131ld\u0131\u011f\u0131ndan emin olun ve birka\u00e7 dakika stabil hale gelmesine izin verin.<\/p>\n<p>Cihaz stabil hale geldikten sonra, \u00f6l\u00e7\u00fcm cihaz\u0131 \u00fczerindeki kalibrasyon d\u00fc\u011fmesini, okunan de\u011fer 1,41 mS\/cm olan beklenen de\u011ferle e\u015fle\u015fene kadar ayarlay\u0131n. E\u011fer okuma e\u015fle\u015fmiyorsa, \u00f6l\u00e7\u00fcm cihaz\u0131 uygun \u015fekilde kalibre edilinceye kadar i\u015flemi tekrarlay\u0131n. 1,41 mS\/cm kalibrasyonu tamamland\u0131ktan sonra sens\u00f6r\u00fc dam\u0131t\u0131lm\u0131\u015f suyla durulay\u0131n ve i\u015flemi 12,88 mS\/cm kalibrasyon standard\u0131yla tekrarlay\u0131n.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/shchimay.com\/wp-content\/uploads\/2024\/09\/FL-9900-High-Precision-Type-Runner-Flow-Controller1.jpg\" alt=\"alt-9121\" class=\"wp-image-9121\" id=\"i9121\" \/><\/p>\n<p>\nKulland\u0131\u011f\u0131n\u0131z iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n t\u00fcr\u00fcne ba\u011fl\u0131 olarak kalibrasyon i\u015fleminin de\u011fi\u015febilece\u011fini unutmamak \u00f6nemlidir. Belirli modelinizin kalibre edilmesine ili\u015fkin \u00f6zel y\u00f6nergeler i\u00e7in \u00fcreticinin talimatlar\u0131na bak\u0131n. Ek olarak \u00e7evresel fakt\u00f6rler ve normal a\u015f\u0131nma ve y\u0131pranma \u00f6l\u00e7\u00fcmlerin do\u011frulu\u011funu etkileyebilece\u011finden iletkenlik \u00f6l\u00e7erin d\u00fczenli olarak kalibre edilmesi \u00f6nerilir.<\/p>\n<p>\u0130letkenlik \u00f6l\u00e7erin kalibrasyon standartlar\u0131yla kalibre edilmesinin yan\u0131 s\u0131ra e\u011fim do\u011frulamas\u0131 yap\u0131lmas\u0131 da \u00f6nemlidir. test. Bu test, \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n \u00e7\u00f6zeltinin iletkenli\u011fini \u00e7e\u015fitli de\u011ferlerde do\u011fru bir \u015fekilde \u00f6l\u00e7mesini sa\u011flar. E\u011fim do\u011frulama testini ger\u00e7ekle\u015ftirmek i\u00e7in artan iletkenlik de\u011ferlerine (\u00f6rne\u011fin, 1,41 mS\/cm, 5,0 mS\/cm ve 12,88 mS\/cm) sahip bir dizi kalibrasyon standard\u0131 haz\u0131rlay\u0131n ve her \u00e7\u00f6z\u00fcm\u00fcn iletkenli\u011fini \u00f6l\u00e7\u00fcn.<\/p>\n<p>\u00d6l\u00e7\u00fclen de\u011ferleri \u00e7izin beklenen de\u011ferleri kar\u015f\u0131la\u015ft\u0131r\u0131n ve do\u011frunun e\u011fimini hesaplay\u0131n. E\u011fimin 1&#8217;e yak\u0131n olmas\u0131, \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n \u00e7\u00f6zeltilerin iletkenli\u011fini do\u011fru bir \u015fekilde \u00f6l\u00e7t\u00fc\u011f\u00fcn\u00fc g\u00f6sterir. E\u011fimin 1&#8217;den \u00f6nemli \u00f6l\u00e7\u00fcde sapmas\u0131, sayac\u0131n yeniden kalibre edilmesi veya servise verilmesi gerekti\u011fini g\u00f6sterebilir.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\">ROC-2315 RO kontrol cihaz\u0131 talimat\u0131 (220V)<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td colspan=\"3\">ROC-2315<\/td>\n<\/tr>\n<tr>\n<td>Tek alg\u0131lama<\/td>\n<td rowspan=\"6\">Kuru Kontak giri\u015fi<\/td>\n<td colspan=\"2\">Ham su, susuz koruma<\/td>\n<\/tr>\n<tr>\n<td>(alt\u0131 kanal)<\/td>\n<td colspan=\"2\">D\u00fc\u015f\u00fck bas\u0131n\u00e7 korumas\u0131<\/td>\n<\/tr>\n<tr>\n<td>\\\u3000<\/td>\n<td colspan=\"2\">Y\u00fcksek bas\u0131n\u00e7 korumas\u0131<\/td>\n<\/tr>\n<tr>\n<td>\\\u3000<\/td>\n<td colspan=\"2\">Saf su deposu y\u00fcksek\\\u00a0seviye<\/td>\n<\/tr>\n<tr>\n<td>\\\u3000<\/td>\n<td colspan=\"2\">Harici kontrol modu sinyali<\/td>\n<\/tr>\n<tr>\n<td>\\\u3000<\/td>\n<td colspan=\"2\">\u00c7al\u0131\u015ft\u0131rma s\u0131f\u0131rlamas\u0131<\/td>\n<\/tr>\n<tr>\n<td>Kontrol ba\u011flant\u0131 noktas\u0131<\/td>\n<td rowspan=\"5\">Kuru Kontak \u00e7\u0131k\u0131\u015f\u0131<\/td>\n<td>Ham su pompas\u0131<\/td>\n<td>SPST-NO d\u00fc\u015f\u00fck kapasite: AC220V\/3A Maks ;AC110V\/5A Maks<\/td>\n<\/tr>\n<tr>\n<td>(be\u015f kanal)<\/td>\n<td>Giri\u015f valfi<\/td>\n<td>\\\u3000<\/td>\n<\/tr>\n<tr>\n<td>\\\u3000<\/td>\n<td>Y\u00fcksek bas\u0131n\u00e7 pompas\u0131<\/td>\n<td>\\\u3000<\/td>\n<\/tr>\n<tr>\n<td>\\\u3000<\/td>\n<td>Y\u0131kama vanas\u0131<\/td>\n<td>\\\u3000<\/td>\n<\/tr>\n<tr>\n<td>\\\u3000<\/td>\n<td>\u0130letkenlik limit a\u015f\u0131m\u0131 tahliye vanas\u0131<\/td>\n<td>\\\u3000<\/td>\n<\/tr>\n<tr>\n<td>\u00d6l\u00e7\u00fcm alg\u0131lama noktas\u0131<\/td>\n<td colspan=\"3\">\u00dcr\u00fcn su iletkenli\u011fi ve Otomatik S\u0131cakl\u0131k telafisi ile (0\\\uff5e50\\\uff09\\\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\u00d6l\u00e7\u00fcm aral\u0131\u011f\u0131<\/td>\n<td colspan=\"3\">\u0130letkenlik : 0,1~200\\\u03bcS\/cm\/1~2000\\\u03bcS\/cm\/10~999\\\u03bcS\/cm (farkl\u0131 iletkenlik sens\u00f6r\u00fcyle)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\u00dcr\u00fcn su s\u0131cakl\u0131\u011f\u0131. : 0~50\\\u2103<\/td>\n<\/tr>\n<tr>\n<td>Do\u011fruluk<\/td>\n<td colspan=\"3\">1,5 seviye<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 kayna\u011f\u0131<\/td>\n<td colspan=\"3\">AC220V (\u0000\u00fczde110)\\\u00a0,\\\u00a050\/60Hz<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\u00c7al\u0131\u015fma ortam\u0131<\/td>\n<td colspan=\"3\">S\u0131cakl\u0131k:\\\uff080\\\uff5e50\\\uff09\\\u2103\\\u00a0;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Ba\u011f\u0131l Nem :\\\u226485 y\u00fczde RH\\\u00a0(yo\u011fu\u015fmas\u0131z)<\/td>\n<\/tr>\n<tr>\n<td>Boyut<\/td>\n<td colspan=\"3\">96\\\u00d796\\\u00d7130mm( y\u00fckseklik \\\u00d7geni\u015flik\\\u00d7derinlik)<\/td>\n<\/tr>\n<tr>\n<td>Delik boyutu<\/td>\n<td colspan=\"3\">91\\\u00d791mm\\\uff08y\u00fckseklik \\\u00d7geni\u015flik\\\uff09<\/td>\n<\/tr>\n<tr>\n<td>Kurulum<\/td>\n<td colspan=\"3\">Panele monte, h\u0131zl\u0131 kurulum<\/td>\n<\/tr>\n<tr>\n<td>Sertifika<\/td>\n<td colspan=\"3\">CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nSonu\u00e7 olarak, bir iletkenlik \u00f6l\u00e7erin USP standartlar\u0131na g\u00f6re kalibre edilmesi, \u00e7e\u015fitli \u00e7\u00f6z\u00fcmlerde iletkenli\u011fin do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmlerinin sa\u011flanmas\u0131nda kritik bir ad\u0131md\u0131r. Bu makalede \u00f6zetlenen ad\u0131m ad\u0131m k\u0131lavuzu takip ederek ve d\u00fczenli kalibrasyon ve e\u011fim do\u011frulama testleri ger\u00e7ekle\u015ftirerek iletkenlik \u00f6l\u00e7\u00fcmlerinizin do\u011frulu\u011funu ve tutarl\u0131l\u0131\u011f\u0131n\u0131 koruyabilirsiniz. \u0130letkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n kalibrasyonuna ili\u015fkin \u00f6zel y\u00f6nergeler i\u00e7in \u00fcreticinin talimatlar\u0131na ba\u015fvurmay\u0131 unutmay\u0131n.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u0130la\u00e7 End\u00fcstrisinde \u0130letkenlik \u00d6l\u00e7erlerde D\u00fczenli Kalibrasyonun \u00d6nemi \u0130la\u00e7 end\u00fcstrisinde, \u00e7\u00f6zeltilerin iletkenli\u011finin \u00f6l\u00e7\u00fclmesi s\u00f6z konusu oldu\u011funda do\u011fruluk ve kesinlik son derece \u00f6nemlidir. \u0130letkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131, test edilen \u00e7\u00f6z\u00fcmlerin gerekli standartlar\u0131 kar\u015f\u0131lad\u0131\u011f\u0131ndan emin olmak i\u00e7in farmas\u00f6tik laboratuvarlarda yayg\u0131n olarak kullan\u0131lmaktad\u0131r. Bu \u00f6l\u00e7\u00fcmlerin do\u011frulu\u011funu korumak i\u00e7in iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n d\u00fczenli kalibrasyonu \u015fartt\u0131r. Kalibrasyon, do\u011frulu\u011funu sa\u011flamak i\u00e7in bir \u00f6l\u00e7\u00fcm&#8230;<\/p>\n","protected":false},"author":1,"featured_media":21429,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"default","_kad_post_title":"default","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[200],"tags":[158,134429,163],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"tr","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/25219"}],"collection":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/comments?post=25219"}],"version-history":[{"count":17,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/25219\/revisions"}],"predecessor-version":[{"id":26066,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/25219\/revisions\/26066"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/media\/21429"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/media?parent=25219"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/categories?post=25219"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/tags?post=25219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}