{"id":9825,"date":"2024-04-02T13:48:10","date_gmt":"2024-04-02T05:48:10","guid":{"rendered":"https:\/\/shchimay.com\/?p=9825"},"modified":"2024-04-03T09:14:21","modified_gmt":"2024-04-03T01:14:21","slug":"on-the-chemical-controller-what-does-orp-effect","status":"publish","type":"post","link":"https:\/\/shchimay.com\/tr\/on-the-chemical-controller-what-does-orp-effect\/","title":{"rendered":"kimyasal kontrol\u00f6rde orp etkisi nedir"},"content":{"rendered":"<p>&#8220;Hassas ORP kontrol\u00fcyle su kalitenizi optimize edin.&#8221;<\/p>\n<h1 id=\"understanding-the-impact-of-orp-on-chemical-controllers-wpaicgheading\">ORP&#8217;nin Kimyasal Kontrol\u00f6rler \u00dczerindeki Etkisini Anlamak<\/h1>\n<p>\nPOP-8300 serbest klor \u00e7evrimi\u00e7i analiz\u00f6r\u00fc<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"1804 2-Way Male Thread Side connectors\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/tDTyyHK6jVQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p><\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\">Sistem Modeli<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">POP-8300 serbest klor \u00e7evrimi\u00e7i analiz\u00f6r\u00fc<\/td>\n<td>\u00d6l\u00e7\u00fcm konfig\u00fcrasyonu<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">(HClO)serbest klor..<\/td>\n<td>toplam serbest klor\/(ClO2)\/pH\/S\u0131cakl\u0131k<\/td>\n<\/tr>\n<tr>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Serbest klor<\/td>\n<td>(0,00-2,00)mg\/L(ppm); ve nbsp; ve nbsp; (0,00-20,00)mg\/L(ppm)<\/td>\n<td>\u00d6l\u00e7\u00fcm<\/td>\n<\/tr>\n<tr>\n<td>pH<\/td>\n<td>aral\u0131k<\/td>\n<td>2.00-12.00<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td>(0,0-99,9)\u2103<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Serbest klor<\/td>\n<td>0,01 mg\/L(ppm)<\/td>\n<td>\u00c7\u00f6z\u00fcn\u00fcrl\u00fck<\/td>\n<\/tr>\n<tr>\n<td>pH<\/td>\n<td>\u3000<\/td>\n<td>0.01<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td>0,1\u2103<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Serbest klor<\/td>\n<td>G\u00f6sterge hatas\u0131 y\u00fczde 10 <\/td>\n<td>Do\u011fruluk<\/td>\n<\/tr>\n<tr>\n<td>pH<\/td>\n<td>0.1pH<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td>\u00b10,5\u2103<\/td>\n<td>Sens\u00f6r \u00f6mr\u00fc<\/td>\n<\/tr>\n<tr>\n<td>pH\/serbest klor sens\u00f6r\u00fc<\/td>\n<td>12 ay(Hizmet \u00f6mr\u00fc, \u00f6l\u00e7\u00fcm ortam\u0131 ve bak\u0131m s\u0131kl\u0131\u011f\u0131 ile yak\u0131ndan ilgilidir)<\/td>\n<td>\u0130leti\u015fim aray\u00fcz\u00fc<\/td>\n<\/tr>\n<tr>\n<td>RS485<\/td>\n<td>MODBUS RTU ileti\u015fim protokol\u00fc<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Kanal say\u0131s\u0131<\/td>\n<td>\u00c7ift kanallar<\/td>\n<td>(4-20)mA<\/td>\n<\/tr>\n<tr>\n<td>Teknik \u00f6zellik<\/td>\n<td>\u0130zole, ters \u00e7evrilebilir, tamamen ayarlanabilir, cihaz\/verici ikili modu<\/td>\n<td>\u00e7\u0131k\u0131\u015f<\/td>\n<\/tr>\n<tr>\n<td>Kanal konfig\u00fcrasyonu<\/td>\n<td>Serbest klor, klor dioksit, S\u0131cakl\u0131k, pH olarak programlanabilir nokta<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>D\u00f6ng\u00fc direnci<\/td>\n<td>400\u03a9(Maks), DC 24V<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>\u0130letim do\u011frulu\u011fu<\/td>\n<td>\u00b10,1mA<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Kanal say\u0131s\u0131<\/td>\n<td>\u00c7ift kanallar<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim modu<\/td>\n<td>Fotoelektrik anahtar i\u00e7in birinci ve ikinci<\/td>\n<td>Kontrol \u00e7\u0131k\u0131\u015f\u0131<\/td>\n<\/tr>\n<tr>\n<td>Y\u00fck kapasitesi<\/td>\n<td>Y\u00fck ak\u0131m\u0131 50mA(Maks)\uff0cAC\/DC 30V<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Kontrol noktas\u0131<\/td>\n<td>Programlanabilir fonksiyon (Serbest klor, klor dioksit, S\u0131cakl\u0131k, pH, Zamanlama)<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Y\u00fck kapasitesi<\/td>\n<td>Y\u00fck ak\u0131m\u0131 50mA(Maks)\uff0cAC\/DC 30V<\/td>\n<td>\u3000<\/td>\n<\/tr>\n<tr>\n<td>Kontrol noktas\u0131<\/td>\n<td>Programlanabilir fonksiyon (Serbest klor, klor dioksit, S\u0131cakl\u0131k, pH, Zamanlama)<\/td>\n<td>G\u00fc\u00e7 kayna\u011f\u0131<\/td>\n<\/tr>\n<tr>\n<td>Elektrik kayna\u011f\u0131na ba\u011fl\u0131<\/td>\n<td colspan=\"2\">\u3000<\/td>\n<\/tr>\n<tr>\n<td>AC80-260V;50\/60Hz, t\u00fcm uluslararas\u0131 cihazlarla uyumlu<\/td>\n<td colspan=\"2\">\u3000<\/td>\n<\/tr>\n<tr>\n<td>piyasa g\u00fc\u00e7 standartlar\u0131(110V;220V;260V;50\/60Hz).<\/td>\n<td colspan=\"2\">\u00c7al\u0131\u015fma ortam\u0131<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k:(5-50)\u2103\uff1ba\u011f\u0131l nem:\u226485 y\u00fczde ba\u011f\u0131l nem(yo\u011fu\u015fmas\u0131z)<\/td>\n<td>\u3000<\/td>\n<td>G\u00fc\u00e7 T\u00fcketimi<\/td>\n<\/tr>\n<tr>\n<td>20W<\/td>\n<td colspan=\"2\">Depolama ortam\u0131<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k:(-20-70)\u2103\uff1ba\u011f\u0131l nem:\u226485 y\u00fczde ba\u011f\u0131l nem(yo\u011fu\u015fmas\u0131z)<\/td>\n<td colspan=\"2\">Kurulum<\/td>\n<\/tr>\n<tr>\n<td>Duvara monte (\u00f6nceden ayarlanm\u0131\u015f arka kapakla)<\/td>\n<td colspan=\"2\">Kabin a\u011f\u0131rl\u0131\u011f\u0131<\/td>\n<\/tr>\n<tr>\n<td>\u226410kg<\/td>\n<td colspan=\"2\">Dolap boyutu<\/td>\n<\/tr>\n<tr>\n<td>570*mm*380mm*130mm(Y\u00d7G\u00d7D)<\/td>\n<td colspan=\"2\">\u00dcr\u00fcn Modeli<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>MFC-8800<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>\u0130leti\u015fim ba\u011flant\u0131 noktas\u0131<\/td>\n<td colspan=\"2\">Yukar\u0131 ba\u011flant\u0131 k\u00f6le kanal\u0131 Modbus RTU protokol\u00fc RS485 ba\u011flant\u0131 noktas\u0131 DTU ve DCS&#8217;ye ba\u011flan\u0131r<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Downlink ana kanal\u0131 Modbus RTU protokol\u00fcn\u00fcn RS485 portu veri toplama terminaline ba\u011flan\u0131r<\/td>\n<td colspan=\"2\">4~20mA ve nbsp;\u00e7\u0131k\u0131\u015f<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">1 kanall\u0131 iki telli tip ve nbsp;Maksimum d\u00f6ng\u00fc direnci 400\u03a9<\/td>\n<\/tr>\n<tr>\n<td>4~20mA ve nbsp;Giri\u015f<\/td>\n<td colspan=\"2\"> ve nbsp;2 kanall\u0131 kanal iki telli tip\uff08 ve nbsp;inisiyatif besleme\uff09<\/td>\n<\/tr>\n<tr>\n<td>DI ve nbsp;Giri\u015f<\/td>\n<td colspan=\"2\"> ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp; ve nbsp;2 kanall\u0131 Fotoelektrik izolasyon mant\u0131k anahtar\u0131<\/td>\n<\/tr>\n<tr>\n<td>DO \u00c7\u0131k\u0131\u015f\u0131<\/td>\n<td colspan=\"2\">3 ve nbsp;kanal r\u00f6lesi<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">1 ve nbsp;SPDT ve nbsp;AC220V\uff1b 3A(MAX)<\/td>\n<td>\uff08yaln\u0131zca s\u00fcr\u00fcc\u00fc sinyali i\u00e7in\uff09<\/td>\n<td>2 ve nbsp;SPST ve nbsp;AC220V\uff1b 3A(MAX)<\/td>\n<\/tr>\n<tr>\n<td>1kanal ve nbsp;Fotoelektrik anahtar ve nbsp; ve nbsp;<\/td>\n<td>Orant\u0131l\u0131 darbe\/frekans<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"> ve nbsp;Y\u00fck kapasitesi\uff1a100mA\/DC30V<\/td>\n<td> ve nbsp;Veri toplama<\/td>\n<\/tr>\n<tr>\n<td>Veri toplama toplama\uff0c3 ve nbsp;kanall\u0131 DC24V sens\u00f6r g\u00fc\u00e7 kayna\u011f\u0131 ve nbsp;<\/td>\n<\/tr>\n<tr>\n<td>Ekran modu<\/td>\n<td colspan=\"2\">3,5\u201d\uff08veya 4\u201d\uff09renkli LCD ve dokunmatik ekran<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 kayna\u011f\u0131<\/td>\n<td colspan=\"2\">Geni\u015f g\u00fc\u00e7 aral\u0131\u011f\u0131 \uff1a\uff0812-24\uff09V<\/td>\n<\/tr>\n<tr>\n<td>T\u00fcketim<\/td>\n<td colspan=\"2\"> ve lt;5W<\/td>\n<\/tr>\n<tr>\n<td>Ortam gereksinimleri<\/td>\n<td colspan=\"2\">Ortam s\u0131cakl\u0131\u011f\u0131\uff1a\uff085~45\uff09\u2103\uff1b ve nbsp;ba\u011f\u0131l nem\uff1a\u226490 y\u00fczde \u3002<\/td>\n<\/tr>\n<tr>\n<td>Delik boyutu<\/td>\n<td colspan=\"2\">\uff0891\u00d791\uff09mm ve nbsp;delik boyutu\uff1bpanel boyutu\uff08100*100\uff09mm<\/td>\n<\/tr>\n<tr>\n<td>Kimyasal kontrol\u00f6rler, ORP seviyesini s\u00fcrekli izleyerek ve suya eklenen dezenfektan miktar\u0131n\u0131 ayarlayarak g\u00fcvenli ve sa\u011fl\u0131kl\u0131 bir y\u00fczme ortam\u0131n\u0131n korunmas\u0131na yard\u0131mc\u0131 olur. ORP seviyesi genellikle havuz operat\u00f6r\u00fc taraf\u0131ndan su s\u0131cakl\u0131\u011f\u0131, y\u00fcz\u00fcc\u00fc y\u00fck\u00fc ve \u00e7evre ko\u015fullar\u0131 gibi fakt\u00f6rlere g\u00f6re ayarlan\u0131r. Kimyasal kontrol\u00f6r daha sonra bu ayar noktas\u0131n\u0131, ORP seviyesini istenen aral\u0131kta tutmak amac\u0131yla suya eklenen dezenfektan miktar\u0131n\u0131 d\u00fczenlemek i\u00e7in kullan\u0131r.<\/td>\n<td colspan=\"2\">Kimyasal kontrol\u00f6rlerde ORP&#8217;nin etkiledi\u011fi temel fakt\u00f6rlerden biri sudaki oksidasyon ve indirgeme reaksiyonlar\u0131n\u0131n h\u0131z\u0131d\u0131r. Oksidasyon, bir maddeden elektronlar\u0131n uzakla\u015ft\u0131r\u0131lmas\u0131 i\u015flemidir, indirgeme ise elektronlar\u0131n eklenmesi i\u015flemidir. Su ar\u0131t\u0131m\u0131nda, oksidasyon reaksiyonlar\u0131 organik kirleticileri par\u00e7alamak ve bakterileri \u00f6ld\u00fcrmek i\u00e7in kullan\u0131l\u0131rken, indirgeme reaksiyonlar\u0131 oksidasyonun zararl\u0131 yan \u00fcr\u00fcnlerini n\u00f6tralize etmeye yard\u0131mc\u0131 olur.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\n<img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/\u56fe1.jpg\" alt=\"alt-303\" class=\"wp-image-303\" id=\"i303\" \/><br \/>\nORP seviyesinin \u00e7ok d\u00fc\u015f\u00fck olmas\u0131, suda bakterileri etkili bir \u015fekilde \u00f6ld\u00fcrmek ve kirletici maddeleri par\u00e7alamak i\u00e7in yeterli oksitleyici g\u00fcc\u00fcn bulunmad\u0131\u011f\u0131n\u0131 g\u00f6sterir. Bu durumda kimyasal kontrol\u00f6r, ORP seviyesini y\u00fckseltmek ve su kalitesini iyile\u015ftirmek i\u00e7in suya eklenen dezenfektan miktar\u0131n\u0131 art\u0131racakt\u0131r. \u00d6te yandan, ORP seviyesinin \u00e7ok y\u00fcksek olmas\u0131, suda a\u015f\u0131r\u0131 oksitleyici g\u00fcc\u00fcn bulundu\u011funu ve bunun da zararl\u0131 dezenfeksiyon yan \u00fcr\u00fcnlerinin olu\u015fmas\u0131na yol a\u00e7abilece\u011fini g\u00f6sterir. Bu durumda kimyasal kontrol\u00f6r, ORP seviyesini d\u00fc\u015f\u00fcrmek ve a\u015f\u0131r\u0131 oksidasyonu \u00f6nlemek i\u00e7in suya eklenen dezenfektan miktar\u0131n\u0131 azaltacakt\u0131r.<\/p>\n<p>Genel olarak ORP, kimyasal kontrol\u00f6rlerde, su miktar\u0131n\u0131 d\u00fczenleyerek istenen su kalitesinin korunmas\u0131na yard\u0131mc\u0131 olan kritik bir parametredir. Suya eklenen dezenfektan miktar\u0131. Kimyasal kontrol\u00f6rler, ORP seviyesini izleyerek ve kimyasal dozunu buna g\u00f6re ayarlayarak suyun y\u00fcz\u00fcc\u00fcler i\u00e7in g\u00fcvenli ve temiz kalmas\u0131n\u0131 sa\u011flar. ORP&#8217;nin kimyasal kontrol\u00f6rler \u00fczerindeki etkisini anlamak, havuz operat\u00f6rleri ve su ar\u0131tma profesyonellerinin su kalitesini etkili bir \u015fekilde y\u00f6netmeleri ve sa\u011fl\u0131kl\u0131 bir y\u00fczme ortam\u0131 sa\u011flamalar\u0131 a\u00e7\u0131s\u0131ndan \u00e7ok \u00f6nemlidir.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"Reverse Osmosis Controller introduction\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/Az3n9fYEmZA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p><img decoding=\"async\" src=\"https:\/\/shchimay.com\/wp-content\/uploads\/2024\/04\/EC-9900-Conductivity-Resistivity-Measurement-and-Control-Instrument1.png\" alt=\"alt-305\" class=\"wp-image-305\" id=\"i305\" \/><br \/>\nOne of the key factors that ORP affects in chemical controllers is the rate of oxidation and reduction reactions in the water. Oxidation is the process of removing electrons from a substance, while reduction is the process of adding electrons. In water treatment, oxidation reactions are used to break down organic contaminants and kill bacteria, while reduction reactions help neutralize harmful byproducts of oxidation.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"industrial ro controller introduction\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/pVT8_X616O0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>When the ORP level is too low, it indicates that there is not enough oxidizing power in the water to effectively kill bacteria and break down contaminants. In this case, the chemical controller will increase the amount of disinfectant added to the water to raise the ORP level and improve water quality. On the other hand, if the ORP level is too high, it suggests that there is an excess of oxidizing power in the water, which can lead to the formation of harmful disinfection byproducts. In this case, the chemical controller will reduce the amount of disinfectant added to the water to lower the ORP level and prevent over-oxidation.<\/p>\n<p>Overall, ORP is a critical parameter in chemical controllers that helps maintain the desired water quality by regulating the amount of disinfectant added to the water. By monitoring the ORP level and adjusting the chemical dosing accordingly, chemical controllers ensure that the water remains safe and clean for swimmers. Understanding the impact of ORP on chemical controllers is essential for pool operators and water treatment professionals to effectively manage water quality and ensure a healthy swimming environment.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&#8220;Hassas ORP kontrol\u00fcyle su kalitenizi optimize edin.&#8221; ORP&#8217;nin Kimyasal Kontrol\u00f6rler \u00dczerindeki Etkisini Anlamak POP-8300 serbest klor \u00e7evrimi\u00e7i analiz\u00f6r\u00fc Sistem Modeli POP-8300 serbest klor \u00e7evrimi\u00e7i analiz\u00f6r\u00fc \u00d6l\u00e7\u00fcm konfig\u00fcrasyonu (HClO)serbest klor.. toplam serbest klor\/(ClO2)\/pH\/S\u0131cakl\u0131k \u3000 Serbest klor (0,00-2,00)mg\/L(ppm); ve nbsp; ve nbsp; (0,00-20,00)mg\/L(ppm) \u00d6l\u00e7\u00fcm pH aral\u0131k 2.00-12.00 S\u0131cakl\u0131k (0,0-99,9)\u2103 \u3000 Serbest klor 0,01 mg\/L(ppm) \u00c7\u00f6z\u00fcn\u00fcrl\u00fck pH \u3000&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1472,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[200],"tags":[],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"tr","enabled_languages":["en","zh","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"zh":{"title":false,"content":false,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"de":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"pt":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"ja":{"title":false,"content":false,"excerpt":false},"ko":{"title":false,"content":false,"excerpt":false},"it":{"title":false,"content":false,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"th":{"title":false,"content":false,"excerpt":false},"vi":{"title":false,"content":false,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/9825"}],"collection":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/comments?post=9825"}],"version-history":[{"count":4,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/9825\/revisions"}],"predecessor-version":[{"id":9848,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/posts\/9825\/revisions\/9848"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/media\/1472"}],"wp:attachment":[{"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/media?parent=9825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/categories?post=9825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shchimay.com\/tr\/wp-json\/wp\/v2\/tags?post=9825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}