How to Properly Calibrate and Use a Hach pH Tester

A Hach pH tester is a valuable tool for measuring the acidity or alkalinity of a solution. Proper calibration and usage of this device are essential to ensure accurate and reliable results. In this article, we will discuss how to properly calibrate and use a Hach pH tester to obtain precise pH measurements.

Before using a Hach pH tester, it is crucial to calibrate the device to ensure accurate readings. Calibration involves adjusting the pH tester to match the pH of known standard solutions. This process helps to eliminate any potential errors in the measurements taken by the device.


To calibrate a Hach pH tester, you will need at least two standard buffer solutions with known pH values. These solutions should cover the range of pH values that you expect to measure. It is recommended to use buffer solutions that are close to the pH of the samples you will be testing.

CCT-3300
Constant 10.00cm-1 1.000cm-1 0.100cm-1 0.010cm-1
Conductivity (500\uff5e20,000) (1.0\uff5e2,000) (0.5\uff5e200) (0.05\uff5e18.25)
\u03bcS/cm \u03bcS/cm \u03bcS/cm M\u03a9\u00b7cm
TDS (250\uff5e10,000) (0.5\uff5e1,000) (0.25\uff5e100) \u2014\u2014
ppm ppm ppm
Medium Temp. (0\uff5e50)\u2103\uff08Temp. Compensation : NTC10K\uff09
Resolution Conductivity: 0.01\u03bcS/cm\uff1b0.01mS/cm
TDS: 0.01ppm
Temp.: 0.1\u2103
Accuracy Conductivity:1.5%\uff08FS\uff09
Resistivity: 2.0%\uff08FS\uff09
TDS:1.5%\uff08FS\uff09
Temp:\u00b10.5\u2103
Analog Output Single isolated(4\uff5e20)mA\uff0cinstrument/transmitter for selection
Control Output SPDT relay\uff0cLoad Capacity: AC 230V/50A(Max)
Working Environment Temp:\u00a0(0\uff5e50)\u2103\uff1bRelative humidity\uff1a\u00a0\u226485%RH(none condensation)
Storage Environment Temp:(-20\uff5e60)\u2103; Relative humidity\u00a0\u226485%RH(none condensation)
Power Supply DC 24V/AC 110V/AC 220V\u00b115%\uff08for selection\uff09
Dimension 48mm\u00d796mm\u00d780mm (H\u00d7W\u00d7D)
Hole Size 44mm\u00d792mm (H\u00d7W)
Installation Panel mounted, fast installation

Start by turning on the pH tester and allowing it to warm up for a few minutes. Once the device is ready, immerse the electrode into the first buffer solution and wait for the reading to stabilize. Use the device’s calibration controls to adjust the reading to match the known pH value of the buffer solution. Repeat this process with the second buffer solution to ensure accurate calibration across the entire pH range.

After calibrating the pH tester, you can begin using it to measure the pH of your samples. To obtain accurate results, it is essential to properly prepare the samples and handle the device with care. Make sure to clean the electrode with distilled water before and after each use to prevent contamination and ensure accurate readings.

When measuring the pH of a sample, gently stir the solution with the electrode to ensure a uniform reading. Allow the reading to stabilize before recording the pH value. It is also important to rinse the electrode with distilled water between measurements to prevent cross-contamination.

If you are testing multiple samples, make sure to recalibrate the pH tester periodically to maintain accuracy. It is recommended to recalibrate the device after every 10 measurements or whenever you switch between different pH ranges.

In addition to proper calibration and usage, it is essential to store the pH tester correctly to prolong its lifespan and maintain accuracy. Store the device in a clean, dry place away from direct sunlight and extreme temperatures. Avoid storing the electrode in distilled water or buffer solutions for an extended period, as this can lead to degradation of the electrode.

alt-3714

In conclusion, a Hach pH tester is a valuable tool for measuring the acidity or alkalinity of a solution. Proper calibration and usage of this device are essential to ensure accurate and reliable results. By following the steps outlined in this article, you can calibrate and use a Hach pH tester effectively to obtain precise pH measurements. Remember to handle the device with care, recalibrate regularly, and store it properly to maintain accuracy and prolong its lifespan.