Understanding the Importance of ph meter 7110 in Various Industries

In various industries, the ph meter 7110 plays a crucial role in ensuring the quality and efficiency of processes. This sophisticated instrument is used to measure the acidity or alkalinity of a solution, providing valuable information that can help maintain optimal conditions for production. Understanding the importance of ph meter 7110 in various industries is essential for maximizing productivity and ensuring the quality of products.

alt-141
One of the key industries that rely heavily on ph meter 7110 is the food and beverage industry. In this sector, maintaining the correct pH levels is critical for ensuring the safety and quality of products. For example, in the production of beverages such as beer and wine, pH levels can impact the fermentation process and ultimately the taste of the final product. By using a ph meter 7110, manufacturers can accurately monitor and adjust pH levels to ensure consistency and quality.

Similarly, in the pharmaceutical industry, ph meter 7110 is used to monitor the pH levels of various solutions and compounds during the manufacturing process. This is crucial for ensuring the effectiveness and stability of pharmaceutical products. By accurately measuring and controlling pH levels, pharmaceutical companies can ensure that their products meet regulatory standards and are safe for consumption.

alt-145
In the agricultural industry, ph meter 7110 is used to monitor soil pH levels, which can have a significant impact on crop yield and quality. By measuring soil pH, farmers can determine the need for lime or other soil amendments to optimize growing conditions for crops. This information is essential for maximizing productivity and ensuring the success of agricultural operations.

In the water treatment industry, ph meter 7110 is used to monitor and control the pH levels of water in treatment plants. Proper pH levels are essential for ensuring the effectiveness of disinfection processes and the safety of drinking water. By using a ph meter 7110, water treatment facilities can accurately monitor and adjust pH levels to meet regulatory standards and ensure the quality of drinking water.

In the environmental monitoring industry, ph meter 7110 is used to measure the pH levels of water bodies, soil, and other environmental samples. This information is essential for assessing the health of ecosystems and identifying potential sources of pollution. By using a ph meter 7110, environmental scientists can gather valuable data that can help inform conservation efforts and protect natural resources.

Controller type ROC-7000 Single-stage/Double-stage Reverse osmosis control integrated system
  Cell constant 0.1cm-1 1.0 cm-1 10.0cm-1
Conductivity  measurement parameters Raw water conductivity       (0~2000) (0~20000)
  Primary conductivity   (0~200) (0~2000)  
  Secondary conductivity   (0~200) (0~2000)  
  Temperature compensation Automatic compensation on the basis of 25 ℃ ,compensation range(0~50)℃
  Accuracy Matched precision:1.5 level
Flow measurement range Instantaneous flow (0~999)m3/h
Accumulative flow (0~9999999)m3
pH Measurement range 2-12
measurement parameters Accuracy ±0.1pH
  Temperature compensation Automatic compensation on the basis of 25 ℃ ,compensation range(0~50)℃
DI acquisition Input signal Low pressure switch of Tap water,high level of pure water tank, low level of pure water tank, low pressure switch before the pump, high pressure switch after the primary booster pump,high level of secondary pure water tank, low level of secondary pure water tank,high pressure switch after the secondary booster pump
Signal Type Passive switch contact
DO Control Control output Inlet valve, primary flush valve, primary drain valve, antiscalant pump, raw water pump, primary booster pump, secondary booster pump, secondary flush valve, secondary drain valve, pH adjustment metering pump.
Electrical contact Relay(ON/OFF)
Load capacity 3A(AC 250V)~ 3A(DC 30V)
Display screen Screen color:TFT;resolution:800×480
Working power Working power DC 24V±4V
Power consumption ≤6.0W
Working environment Temperature:(0~50)℃;Relative humidity:≤85%RH(non condensation)
Storage environment Temperature:(-20~60)℃;Relative humidity:≤85%RH(non condensation)
Installation Panel mounted Hole(Length×Width,192mm×137mm)

Overall, the ph meter 7110 plays a vital role in various industries by providing accurate and reliable measurements of pH levels. By using this sophisticated instrument, companies can ensure the quality and efficiency of their processes, meet regulatory standards, and protect the environment. Understanding the importance of ph meter 7110 in various industries is essential for maximizing productivity and ensuring the success of operations.

ROS-360 Water Treatment RO Programmer Controller
Model ROS-360 Single Stage ROS-360 Double Stage
Measuring range Source water0~2000uS/cm Source water0~2000uS/cm
  First level effluent 0~1000uS/cm First level effluent 0~1000uS/cm
  secondary effluent 0~100uS/cm secondary effluent 0~100uS/cm
Pressure sensor(optional) Membrane pre/post pressure Primary/ secondary membrane front/rear pressure
Flow Sensor(optional) 2 channels (Inlet/outlet flow rate) 3 channels (source water, primary flow,secondary flow)
IO input 1.Raw water low pressure 1.Raw water low pressure
  2.Primary booster pump inlet low pressure 2.Primary booster pump inlet low pressure
  3.Primary booster pump outlet high pressure 3.Primary booster pump outlet high pressure
  4.High liquid level of Level 1 tank 4.High liquid level of Level 1 tank
  5.Low liquid level of Level 1 tank 5.Low liquid level of Level 1 tank
  6.Preprocessing signal  6.2nd booster pump outlet high pressure
    7.High liquid level of Level 2 tank
    8.Preprocessing signal
Relay output (passive) 1.Water inlet valve 1.Water inlet valve
  2.Source water pump 2.Source water pump
  3.Booster pump 3.Primary booster pump
  4.Flush valve 4.Primary flush valve
  5.Water over standard discharge valve 5.Primary water over standard discharge valve
  6.Alarm output node 6.Secondary booster pump
  7.Manual standby pump 7.Secondary flush valve
    8.Secondary water over standard discharge valve
    9.Alarm output node
    10.Manual standby pump
The main function 1.Correction of electrode constant 1.Correction of electrode constant
  2.TDS alarm setting 2.TDS alarm setting
  3.All working mode time can be set 3.All working mode time can be set
  4.High and low pressure flushing mode setting 4.High and low pressure flushing mode setting
  5.Manual/automatic can be chosen when boot up 5.Manual/automatic can be chosen when boot up
  6.Manual debugging mode 6.Manual debugging mode
  7.Spare parts time management 7.Spare parts time management
Expansion interface 1.Reserved relay output 1.Reserved relay output
  2.RS485 communication 2.RS485 communication
Power supply DC24V±10% DC24V±10%
Relative humidity ≦85% ≤85%
Environment temperature 0~50℃ 0~50℃
Touch screen size Touch screen size: 7 inches 203*149*48mm (Hx Wx D) Touch screen size: 7 inches 203*149*48mm (Hx Wx D)
Hole Size 190x136mm(HxW) 190x136mm(HxW)
Installation Embedded Embedded

Similar Posts