FLECK Control Valve 5600
FLECK control valve 5600 softening water equipment generally uses fixed bed downstream
regeneration, the working process is operation, backwashing, regeneration, replacement,
positive washing, salt tank water injection.


FLECK control valve 5600 softening water equipment generally uses fixed bed downstream
regeneration, the working process is operation, backwashing, regeneration, replacement,
positive washing, salt tank water injection.


DR20\40\50\20T\40T Soften valve series is floating bed, all appearance and geometric parameters and parts is the same as the corresponding GR20\40\50\20T\40T, floating bed has a good water quality, to adapt high hardness of the raw water, configuration swap tank should be fine and high, runing velocity in the 30-60 m/h, but resin filling rate must be above 90%, being stable working pressure,The floating bed is not suitable for frequent starting and changing water consumption.


Single stage RO controller used for conductivity monitoring and process program control .

Typical applications • Widely used in thermal boiler deaerator water and large and medium-sized industrial boiler feed water; • Operational supervision of reactor Primary circuit, secondary circuit circuits and condensate system; • On-line analysis of dissolved oxygen in circulating water of heat exchange system; • Deaeration control of marine fresh water system, thermal system and…


“One Dynamic and Two Static” Double Static Ceramics Plates Multi-port Valve is on behalf of another beginning in the field of water treatment control, which can overcome many disadvantages of traditional products in installation.

![[BSQ-MINI] Water Quality Monitoring Transmitter 1](https://shchimay.com/wp-content/uploads/2023/11/BSQ-MINI-Water-Quality-Monitoring-Transmitter-1-300x300.png)
BSQ-MINI is widely used in metallurgical manufacturing, electric power, light industry, textile, water treatment equipment, tap water pipe network and scientific research and other industrial sectors.




Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.


ZR type double tank floating bed control valve including ZR4-1/ZR4-1S(Side Loading), ZR10-1/ZR10-1S(Side Loading). It is equiped the inlet flow Meter and drainage flow meter, All the parameters is set by water volume, The double swap tank is for Alternating regeneration. Continuous water production, Water quality is stable , Adapted to the to high hardness water softening, such as the steam boiler and heating engineering and production process water.